Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT

被引:105
|
作者
Weiss, Elisabeth
Wijesooriya, Krishni
Dill, S. Vaughn
Keall, Paul J.
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] Univ Gottingen, Dept Radiat Oncol, D-3400 Gottingen, Germany
[3] Univ Pittsburgh, Dept Radiat Oncol, Pittsburgh, PA 15260 USA
[4] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
four-dimensional computed tomography; lung cancer; radiotherapy; respiratory motion; normal tissue;
D O I
10.1016/j.ijrobp.2006.09.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate temporospatial variations of tumor and normal tissue during respiration in lung cancer patients. Methods and Materials: In 14 patients, gross tumor volume (GTV) and normal tissue structures were manually contoured on four-dimensional computed tomography (4D-CT) scans. Structures were evaluated for volume changes, centroid (center of mass) motion, and phase dependence of variations relative to inspiration. Only volumetrically complete structures were used for analysis (lung in 2, heart in 8, all other structures in > 10 patients). Results: During respiration, the magnitude of contoured volumes varied up to 62.5% for GTVs, 25.5% for lungs, and 12.6% for hearts. The range of maximum three-dimensional centroid movement for individual patients was 1.3-24.0 mm for GTV, 2.4-7.9 mm for heart, 5.2-12.0 mm for lungs, 0.3-5.5 mm for skin markers, 2.9-10.0 mm for trachea, and 6.6-21.7 mm for diaphragm. During respiration, the centroid positions of normal structures varied relative to the centroid position of the respective GTV by 1.5-8.1 mm for heart, 2.9-9.3 mm for lungs, 1.2-9.2 mm for skin markers, 0.9-7.1 mm for trachea, and 2.7-16.4 mm for diaphragm. Conclusion: Using 4D-CT, volumetric changes, positional alterations as well as changes in the position of contoured structures relative to the GTV were observed with large variations between individual patients. Although the interpretation of 4D-CT data has considerable uncertainty because of 4D-CT artifacts, observer variations, and the limited acquisition time, the findings might have a significant impact on treatment planning. (c) 2007 Elsevier Inc.
引用
收藏
页码:296 / 307
页数:12
相关论文
共 50 条
  • [1] Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT
    Weiss, E.
    Wijesooriya, K.
    Dill, S. V.
    Keall, P. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S484 - S484
  • [2] Correlating lung tumour location and motion with respiration using 4D CT scans
    Siow, T. R.
    Lim, S. K.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (01) : 17 - 21
  • [3] Towards a Generic Respiratory Motion Model for 4D CT Imaging of the Thorax
    Fayad, H.
    Clement, J. F.
    Pan, T.
    Roux, C.
    Le Rest, C. Cheze
    Pradier, O.
    Visvikis, D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3975 - +
  • [4] Impact of 4D CT planning for lung cancer on tumor control probability as a function of the extent of tumor motion with respiration
    Kozono, D.
    Hutchinson, E.
    Schneider, R.
    Sharp, G.
    Niemierko, A.
    Wolfgang, J.
    Doppke, K.
    Choi, N. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S496 - S496
  • [5] A 4D global respiratory motion model of the thorax based on CT images: A proof of concept
    Fayad, Hadi
    Gilles, Marlene
    Pan, Tinsu
    Visvikis, Dimitris
    MEDICAL PHYSICS, 2018, 45 (07) : 3043 - 3051
  • [6] Lung tumor motion measured using retrospective 4D CT and correlated with tumor location and attachment
    Brandner, ED
    Wu, A
    Chen, H
    Heron, D
    Kalnicki, S
    Burton, S
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S288 - S289
  • [7] Motion Vector Field Upsampling for Improved 4D Cone-Beam CT Motion Compensation of the Thorax
    Sauppe, Sebastian
    Rank, Christopher M.
    Brehm, Marcus
    Paysan, Pascal
    Seghers, Dieter
    Kachelriess, Marc
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [8] Investigation of respiratory motion effect on lung tumor radiotherapy using 4D Monte Carlo treatment planning and 4D CT
    Ding, M.
    Xing, L.
    Newman, F.
    MEDICAL PHYSICS, 2006, 33 (06) : 2115 - 2115
  • [9] Respiratory motion-conditioned 4D CT: A method to determine respiratory motion tolerances to reduce motion artifacts during 4D CT acquisition
    Vedam, S
    George, R
    Keall, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S204 - S205
  • [10] Lung tumor segmentation in 4D CT images using motion convolutional neural networks
    Momin, Shadab
    Lei, Yang
    Tian, Zhen
    Wang, Tonghe
    Roper, Justin
    Kesarwala, Aparna H.
    Higgins, Kristin
    Bradley, Jeffrey D.
    Liu, Tian
    Yang, Xiaofeng
    MEDICAL PHYSICS, 2021, 48 (11) : 7141 - 7153