Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT

被引:105
|
作者
Weiss, Elisabeth
Wijesooriya, Krishni
Dill, S. Vaughn
Keall, Paul J.
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] Univ Gottingen, Dept Radiat Oncol, D-3400 Gottingen, Germany
[3] Univ Pittsburgh, Dept Radiat Oncol, Pittsburgh, PA 15260 USA
[4] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
four-dimensional computed tomography; lung cancer; radiotherapy; respiratory motion; normal tissue;
D O I
10.1016/j.ijrobp.2006.09.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate temporospatial variations of tumor and normal tissue during respiration in lung cancer patients. Methods and Materials: In 14 patients, gross tumor volume (GTV) and normal tissue structures were manually contoured on four-dimensional computed tomography (4D-CT) scans. Structures were evaluated for volume changes, centroid (center of mass) motion, and phase dependence of variations relative to inspiration. Only volumetrically complete structures were used for analysis (lung in 2, heart in 8, all other structures in > 10 patients). Results: During respiration, the magnitude of contoured volumes varied up to 62.5% for GTVs, 25.5% for lungs, and 12.6% for hearts. The range of maximum three-dimensional centroid movement for individual patients was 1.3-24.0 mm for GTV, 2.4-7.9 mm for heart, 5.2-12.0 mm for lungs, 0.3-5.5 mm for skin markers, 2.9-10.0 mm for trachea, and 6.6-21.7 mm for diaphragm. During respiration, the centroid positions of normal structures varied relative to the centroid position of the respective GTV by 1.5-8.1 mm for heart, 2.9-9.3 mm for lungs, 1.2-9.2 mm for skin markers, 0.9-7.1 mm for trachea, and 2.7-16.4 mm for diaphragm. Conclusion: Using 4D-CT, volumetric changes, positional alterations as well as changes in the position of contoured structures relative to the GTV were observed with large variations between individual patients. Although the interpretation of 4D-CT data has considerable uncertainty because of 4D-CT artifacts, observer variations, and the limited acquisition time, the findings might have a significant impact on treatment planning. (c) 2007 Elsevier Inc.
引用
收藏
页码:296 / 307
页数:12
相关论文
共 50 条
  • [41] Quantitative analysis of the patellofemoral motion pattern using semi-automatic processing of 4D CT data
    Daniel Forsberg
    Maria Lindblom
    Petter Quick
    Håkan Gauffin
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 1731 - 1741
  • [42] Quantitative analysis of the patellofemoral motion pattern using semi-automatic processing of 4D CT data
    Forsberg, Daniel
    Lindblom, Maria
    Quick, Petter
    Gauffin, Hakan
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (09) : 1731 - 1741
  • [43] 4D Cone-beam CT reconstruction using a motion model based on principal component analysis
    Staub, David
    Docef, Alen
    Brock, Robert S.
    Vaman, Constantin
    Murphy, Martin J.
    MEDICAL PHYSICS, 2011, 38 (12) : 6697 - 6709
  • [44] Compensating respiratory motion in PET image reconstruction using 4D PET/CT
    Qiao, Feng
    Pan, Tinsu
    Clark, John W., Jr.
    Mawlawi, Osama R.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2595 - 2598
  • [45] Using Respiratory Tumor Motion as a Degree of Freedom to Improve 4D IMRT Plans
    Suh, Y.
    Papiez, L.
    Keall, P.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [46] THE DISPLACEMENT OF PRIMARY LUNG CANCER AND NORMAL TISSUES DURING RESPIRATION BY 4D-CT
    Zhang, Ying Jie
    JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (11) : S467 - S467
  • [47] Lung Tumor Motion Tracking Using Sequential Interphase Deformable Registration in 4D CT Images for Radiation Treatment Planning
    Jung, J.
    Jo, H.
    Hong, H.
    Kang, Y.
    Lee, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S668 - S669
  • [48] Analysis of the Dosimetric and Geometrical Variations Caused by Irregular Breathing Patterns on Normal Helical CT and 4D CT Datasets for Lung Cancer SBRT Treatment
    Shiau, A. C.
    Pan, C. H.
    Li, K. C.
    Liang, J. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E558 - E559
  • [49] SQUID 4D CT: Real-time localization based on direct internal tumor motion
    McGary, J. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S650 - S650
  • [50] Respiratory motion variations from skin surface on lung cancer patients from 4D CT data
    Gallego-Ortiz, Nicolas
    de Xivry, Jonathan Orban
    Descampe, Antonin
    Goossens, Samuel
    Geets, Xavier
    Janssens, Guillaume
    Macq, Benoit
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034