Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT

被引:105
|
作者
Weiss, Elisabeth
Wijesooriya, Krishni
Dill, S. Vaughn
Keall, Paul J.
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] Univ Gottingen, Dept Radiat Oncol, D-3400 Gottingen, Germany
[3] Univ Pittsburgh, Dept Radiat Oncol, Pittsburgh, PA 15260 USA
[4] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
four-dimensional computed tomography; lung cancer; radiotherapy; respiratory motion; normal tissue;
D O I
10.1016/j.ijrobp.2006.09.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate temporospatial variations of tumor and normal tissue during respiration in lung cancer patients. Methods and Materials: In 14 patients, gross tumor volume (GTV) and normal tissue structures were manually contoured on four-dimensional computed tomography (4D-CT) scans. Structures were evaluated for volume changes, centroid (center of mass) motion, and phase dependence of variations relative to inspiration. Only volumetrically complete structures were used for analysis (lung in 2, heart in 8, all other structures in > 10 patients). Results: During respiration, the magnitude of contoured volumes varied up to 62.5% for GTVs, 25.5% for lungs, and 12.6% for hearts. The range of maximum three-dimensional centroid movement for individual patients was 1.3-24.0 mm for GTV, 2.4-7.9 mm for heart, 5.2-12.0 mm for lungs, 0.3-5.5 mm for skin markers, 2.9-10.0 mm for trachea, and 6.6-21.7 mm for diaphragm. During respiration, the centroid positions of normal structures varied relative to the centroid position of the respective GTV by 1.5-8.1 mm for heart, 2.9-9.3 mm for lungs, 1.2-9.2 mm for skin markers, 0.9-7.1 mm for trachea, and 2.7-16.4 mm for diaphragm. Conclusion: Using 4D-CT, volumetric changes, positional alterations as well as changes in the position of contoured structures relative to the GTV were observed with large variations between individual patients. Although the interpretation of 4D-CT data has considerable uncertainty because of 4D-CT artifacts, observer variations, and the limited acquisition time, the findings might have a significant impact on treatment planning. (c) 2007 Elsevier Inc.
引用
收藏
页码:296 / 307
页数:12
相关论文
共 50 条
  • [21] Evaluating lung motion variations in repeated 4D CT studies using inverse consistent image registration
    Lu, W.
    Song, J.
    Christensen, G.
    Parikh, P.
    Zhao, T.
    Hubenschmidt, J.
    Bradley, J.
    Low, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2033 - 2033
  • [22] Evaluating lung motion variations in repeated 4D CT studies using inverse consistent image registration
    Lu, W.
    Song, J. H.
    Christensen, G. E.
    Parikh, P. J.
    Zhao, T.
    Hubenschmidt, J. P.
    Bradley, J. D.
    Low, D. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S606 - S607
  • [23] On-Beam 4D CT Reconstruction Using Motion Amplitude Change Provided in Projection Images and Planning 4D CT
    Jung, J.
    Park, S.
    Kim, J.
    Yeo, I.
    Yi, B.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [24] Analysis of free breathing motion using artifact reduced 4D CT image data
    Ehrhardt, Jan
    Werner, Rene
    Frenzel, Thorsten
    Lu, Wei
    Low, Daniel
    Handels, Heinz
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [25] A Novel 4D CT Acquisition and Analysis Technique to Account for the Effect of Cardiac Induced Lung Tissue Motion During Free Breathing
    Thomas, D.
    White, B.
    Gaudio, S.
    Jani, S.
    Lee, P.
    Lamb, J.
    Low, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [26] Brain Tissue Segmentation in 4D CT Using Voxel Classification
    van den Boom, R.
    Oei, M. T. H.
    Lafebre, S.
    Oostveen, L. J.
    Meijer, F. J. A.
    Steens, S. C. A.
    Prokop, M.
    van Ginneken, B.
    Manniesing, R.
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [27] Assess Interfractional Tumor Motion in SBRT Lung Treatment Using 4D Cone-Beam CT
    Li, J.
    Yu, Y.
    Xiao, Y.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [28] 4D registration and 4D verification of lung tumor position for stereotactic volumetric modulated arc therapy using respiratory-correlated cone-beam CT
    Nakagawa, Keiichi
    Haga, Akihiro
    Kida, Satoshi
    Masutani, Yoshitaka
    Yamashita, Hideomi
    Takahashi, Wataru
    Sakumi, Akira
    Saotome, Naoya
    Shiraki, Takashi
    Ohtomo, Kuni
    Iwai, Yoshio
    Yoda, Kiyoshi
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (01) : 152 - 156
  • [29] Planning lung radiotherapy using 4D CT data and a motion model
    Colgan, R.
    McClelland, J.
    McQuaid, D.
    Evans, P. M.
    Hawkes, D.
    Brock, J.
    Landau, D.
    Webb, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20): : 5815 - 5830
  • [30] A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans
    Kim, T.
    Yoon, J.
    Kang, S.
    Suh, T.
    MEDICAL PHYSICS, 2012, 39 (06) : 3684 - 3684