NEMA NU-4 2008 performance evaluation of Xtrim-PET: A prototype SiPM-based preclinical scanner

被引:24
|
作者
Amirrashedi, Mahsa [1 ,2 ]
Sarkar, Saeed [1 ,2 ]
Ghafarian, Pardis [3 ,4 ]
Shahraki, Reza Hashemi [1 ,2 ]
Geramifar, Parham [5 ]
Zaidi, Habib [6 ,7 ,8 ,9 ]
Ay, Mohammad Reza [1 ,2 ]
机构
[1] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Chron Resp Dis Res Ctr, NRITLD, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Masih Daneshvari Hosp, PET CT & Cyclotron Ctr, Tehran, Iran
[5] Univ Tehran Med Sci, Shariati Hosp, Res Ctr Nucl Med, Tehran, Iran
[6] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[7] Univ Geneva, Neuroctr, CH-1205 Geneva, Switzerland
[8] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
[9] Univ Southern Denmark, Dept Nucl Med, DK-500 Odense, Denmark
关键词
detectors; NEMA standard; performance evaluation; PET; small animal imaging; PET/MRI; INSERT; ALGORITHMS; SYSTEM; MRI;
D O I
10.1002/mp.13785
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Xtrim-PET is a newly designed Silicon Photomultipliers (SiPMs)-based prototype PET scanner dedicated for small laboratory animal imaging. We present the performance evaluation of the Xtrim-PET scanner following NEMA NU-4 2008 standards to help optimizing scanning protocols which can be achieved through standard and reliable system performance characterization. Methods The performance assessment was conducted according to the National Electrical Manufacturers Association (NEMA) NU-4 2008 standards in terms of spatial resolution, sensitivity, counting rate performance, scatter fraction and image quality. The in vivo imaging capability of the scanner is also showcased through scanning a normal mouse injected with F-18-FDG. Furthermore, the performance characteristics of the developed scanner are compared with commercially available systems and current prototypes. Results The volumetric spatial resolution at 5 mm radial offset from the central axis of the scanner is 6.81 mu l, whereas a peak absolute sensitivity of 2.99% was achieved using a 250-650 keV energy window and a 10 ns timing window. The peak noise-equivalent count rate (NECR) using a mouse-like phantom is 113.18 kcps at 0.34 KBq/cc with 12.5% scatter fraction, whereas the NECR peaked at 82.76 kcps for an activity concentration level of 0.048 KBq/cc with a scatter fraction of 25.8% for rat-like phantom. An excellent uniformity (3.8%) was obtained using NEMA image quality phantom. Recovery coefficients of 90%, 86%, 68%, 40% and 12% were calculated for rod diameters of 5, 4, 3, 2 and 1 mm, respectively. Spill-over ratios for air-filled and water-filled chambers were 35% and 25% without applying any correction for attenuation and Compton scattering effects. Conclusion Our findings revealed that beyond compactness, lightweight, easy installation and good energy resolution, the Xtrim-PET prototype presents a reasonable performance making it suitable for preclinical molecular imaging-based research.
引用
收藏
页码:4816 / 4825
页数:10
相关论文
共 50 条
  • [21] Performance evaluation of a small-animal PET scanner with 213 mm axis using NEMA NU 4-2008
    Wei, Qing
    Wang, Yingjie
    Huang, Xianchao
    Li, Daowu
    Zheng, Yushuang
    Wang, Peilin
    Sun, Xiaoli
    Chai, Pei
    Han, Xiaorou
    Liu, Shuangquan
    Feng, Baotong
    Zhou, Wei
    Zeng, Xiangtao
    Zhu, Meiling
    Zhang, Zhiming
    Wei, Long
    MEDICAL PHYSICS, 2024,
  • [22] Performance Characterization of an SiPM-based Time-of-Flight Canon PET/CT Scanner
    Li, Xiaoli
    Qi, Wenyuan
    Miyahara, Masaki
    Kolthammer, Jeff
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [23] Performance Test of the MiniPET-II Small Animal Scanner According to the NEMA NU-4 Standard
    Kis, S. A.
    Lajtos, I.
    Emri, M.
    Tron, L.
    Opposits, G.
    Buekki, T.
    Hegyesi, Gy.
    Imrek, J.
    Valastyan, I.
    Molnar, J.
    Novak, D.
    Balkay, L.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3185 - +
  • [24] Performance of 3D MAP in small animal PET: evaluation using the NEMA NU-4 standard phantom
    Khalil, M.
    Gsell, W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S262 - S262
  • [25] NEMA NU4-2008 Comparison of Three Generations of Siemens Preclinical PET Systems
    Goertzen, A. L.
    Tai, Y.
    Bao, Q.
    Chatziioannou, A.
    Laforest, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S334 - S334
  • [26] NEMA NU 4-2008 validation and applications of the PET-SORTEO Monte Carlo simulations platform for the geometry of the Inveon PET preclinical scanner
    Boisson, F.
    Wimberley, C. J.
    Lehnert, W.
    Zahra, D.
    Pham, T.
    Perkins, G.
    Hamze, H.
    Gregoire, M-C
    Reilhac, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (19): : 6749 - 6763
  • [27] Comparison of the Performance Evaluation of the MicroPET R4 Scanner According to NEMA Standards NU 4-2008 and NU 2-2001
    Popota, Fotini D.
    Aguiar, Pablo
    Raul Herance, J.
    Pareto, Deborah
    Rojas, Santiago
    Ros, Domenec
    Pavia, Javier
    Domingo Gispert, Juan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1879 - 1886
  • [28] Performance Evaluation of the SiPM-based Siemens Biograph Vision PET/CT System
    Reddin, Janet S.
    Scheuermann, Joshua S.
    Bharkhada, Deepak
    Smith, Anne M.
    Casey, Michael E.
    Conti, Maurizio
    Karp, Joel S.
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [29] Performance Evaluation of a PET of 7T Bruker Micro-PET/MR Based on NEMA NU 4-2008 Standards
    Doss, Kishore Krishnagiri Manoj
    Mion, Pei En
    Kao, Yu-Chieh Jill
    Kuo, Tsung-Ter
    Chen, Jyh-Cheng
    ELECTRONICS, 2022, 11 (14)
  • [30] Performance Evaluation of the FLEX Triumph X-PET Scanner Using the National Electrical Manufacturers Association NU-4 Standards
    Prasad, Rameshwar
    Ratib, Osman
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (10) : 1608 - 1615