NEMA NU-4 2008 performance evaluation of Xtrim-PET: A prototype SiPM-based preclinical scanner

被引:24
|
作者
Amirrashedi, Mahsa [1 ,2 ]
Sarkar, Saeed [1 ,2 ]
Ghafarian, Pardis [3 ,4 ]
Shahraki, Reza Hashemi [1 ,2 ]
Geramifar, Parham [5 ]
Zaidi, Habib [6 ,7 ,8 ,9 ]
Ay, Mohammad Reza [1 ,2 ]
机构
[1] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Chron Resp Dis Res Ctr, NRITLD, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Masih Daneshvari Hosp, PET CT & Cyclotron Ctr, Tehran, Iran
[5] Univ Tehran Med Sci, Shariati Hosp, Res Ctr Nucl Med, Tehran, Iran
[6] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[7] Univ Geneva, Neuroctr, CH-1205 Geneva, Switzerland
[8] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
[9] Univ Southern Denmark, Dept Nucl Med, DK-500 Odense, Denmark
关键词
detectors; NEMA standard; performance evaluation; PET; small animal imaging; PET/MRI; INSERT; ALGORITHMS; SYSTEM; MRI;
D O I
10.1002/mp.13785
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Xtrim-PET is a newly designed Silicon Photomultipliers (SiPMs)-based prototype PET scanner dedicated for small laboratory animal imaging. We present the performance evaluation of the Xtrim-PET scanner following NEMA NU-4 2008 standards to help optimizing scanning protocols which can be achieved through standard and reliable system performance characterization. Methods The performance assessment was conducted according to the National Electrical Manufacturers Association (NEMA) NU-4 2008 standards in terms of spatial resolution, sensitivity, counting rate performance, scatter fraction and image quality. The in vivo imaging capability of the scanner is also showcased through scanning a normal mouse injected with F-18-FDG. Furthermore, the performance characteristics of the developed scanner are compared with commercially available systems and current prototypes. Results The volumetric spatial resolution at 5 mm radial offset from the central axis of the scanner is 6.81 mu l, whereas a peak absolute sensitivity of 2.99% was achieved using a 250-650 keV energy window and a 10 ns timing window. The peak noise-equivalent count rate (NECR) using a mouse-like phantom is 113.18 kcps at 0.34 KBq/cc with 12.5% scatter fraction, whereas the NECR peaked at 82.76 kcps for an activity concentration level of 0.048 KBq/cc with a scatter fraction of 25.8% for rat-like phantom. An excellent uniformity (3.8%) was obtained using NEMA image quality phantom. Recovery coefficients of 90%, 86%, 68%, 40% and 12% were calculated for rod diameters of 5, 4, 3, 2 and 1 mm, respectively. Spill-over ratios for air-filled and water-filled chambers were 35% and 25% without applying any correction for attenuation and Compton scattering effects. Conclusion Our findings revealed that beyond compactness, lightweight, easy installation and good energy resolution, the Xtrim-PET prototype presents a reasonable performance making it suitable for preclinical molecular imaging-based research.
引用
收藏
页码:4816 / 4825
页数:10
相关论文
共 50 条
  • [11] Performance Evaluation of a PEM Scanner Using the NEMA NU 4-2008 Small Animal PET Standards
    Luo, Weidong
    Anashkin, Edward
    Matthews, Christopher G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 94 - 103
  • [12] Performance evaluation of the Mediso PET scanner to image three mice simultaneously based on the NEMA NU4-2008 standards
    Li, Guiyu
    Ma, Xiaowei
    Wang, Jing
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [13] National Electrical Manufacturers Association NU-4 Performance Evaluation of the PET Component of the NanoPET/CT Preclinical PET/CT Scanner
    Szanda, Istvan
    Mackewn, Jane
    Patay, Gergely
    Major, Peter
    Sunassee, Kavitha
    Mullen, Gregory E.
    Nemeth, Gabor
    Haemisch, York
    Blower, Philip J.
    Marsden, Paul K.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (11) : 1741 - 1747
  • [14] SiPM-based PET detector module for a 4π span scanner
    D-Perez-Benito
    Chil, R.
    Udias, J. M.
    Desco, M.
    Vaquero, J. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 18 - 21
  • [15] Performance Evaluation for 68Ga and 18F of the ARGUS Small-Animal PET Scanner Based on the NEMA NU-4 Standard
    Canadas, M.
    Romero Sanz, E.
    Oteo Vives, M.
    Vaquero, J. J.
    Desco, M.
    Vicente, E.
    Udias, J. M.
    Romero, L.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3454 - 3457
  • [16] PET Performance Evaluation of a Pre-Clinical SiPM-Based MR-Compatible PET Scanner
    Mackewn, Jane E.
    Lerche, Christoph W.
    Weissler, Bjoern
    Sunassee, Kavitha
    de Rosales, Rafael T. M.
    Phinikaridou, Alkystis
    Salomon, Andre
    Ayres, Richard
    Tsoumpas, Charalampos
    Soultanidis, Georgios M.
    Gebhardt, Pierre
    Schaeffter, Tobias
    Marsden, Paul K.
    Schulz, Volkmar
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (03) : 784 - 790
  • [17] Performance evaluation of the small-animal PET scanner ClairvivoPET using NEMA NU 4-2008 Standards
    Sato, K.
    Shidahara, M.
    Watabe, H.
    Watanuki, S.
    Ishikawa, Y.
    Arakawa, Y.
    Nai, Y. H.
    Furumoto, S.
    Tashiro, M.
    Shoji, T.
    Yanai, K.
    Gonda, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02): : 696 - 711
  • [18] PET performance evaluation of the small-animal Hyperion IID PET/MRI insert based on the NEMA NU-4 standard
    Hallen, Patrick
    Schug, David
    Weissler, Bjoern
    Gebhardt, Pierre
    Salomon, Andre
    Kiessling, Fabian
    Schulz, Volkmar
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (06):
  • [19] NEMA NU 4-2008 Comparison of Preclinical PET Imaging Systems
    Goertzen, Andrew L.
    Bao, Qinan
    Bergeron, Melanie
    Blankemeyer, Eric
    Blinder, Stephan
    Canadas, Mario
    Chatziioannou, Arion F.
    Dinelle, Katherine
    Elhami, Esmat
    Jans, Hans-Sonke
    Lage, Eduardo
    Lecomte, Roger
    Sossi, Vesna
    Surti, Suleman
    Tai, Yuan-Chuan
    Jose Vaquero, Juan
    Vicente, Esther
    Williams, Darin A.
    Laforest, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) : 1300 - 1309
  • [20] NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system
    Grant, Alexander M.
    Deller, Timothy W.
    Khalighi, Mohammad Mehdi
    Maramraju, Sri Harsha
    Delso, Gaspar
    Levin, Craig S.
    MEDICAL PHYSICS, 2016, 43 (05) : 2334 - 2343