Noninvasive Blood Pressure Measurement Using the NICCI Monitor in Adolescents During Intraoperative Anesthetic Care

被引:3
|
作者
Owusu-Bediako, Kwaku [1 ]
Bekiroglu, Ismail [1 ]
Rice-Weimer, Julie [1 ]
Murillo-Deluquez, Marcelino [1 ]
Tobias, Joseph D. [1 ,2 ]
机构
[1] Nationwide Childrens Hosp, Dept Anesthesiol & Pain Med, Columbus, OH 43205 USA
[2] Ohio State Univ, Dept Anesthesiol & Pain Med, Columbus, OH 43210 USA
关键词
Continuous blood pressure monitoring; Invasive arterial pressure; Intraoperative monitoring; Pediatrics anesthesiology; DEVICE; ACCURACY; CNAP(TM); SURGERY;
D O I
10.14740/cr1378
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The intermittent measurement of blood pressure (BP) remains the standard of care during anesthesia or procedural sedation. To improve the early identification of hemodynamic compromise, various noninvasive BP devices have been developed which provide a continuous BP reading. The current study evaluates the accuracy of a novel continuous BP device, the NICCI system, in adolescents weighing 40 - 80 kg. Methods: During intraoperative anesthetic care, BP readings (systolic, diastolic, and mean) were captured from the arterial cannula and the NICC1 device every second. Results: The study cohort included 44 pediatric patients undergoing major orthopedic, cardiac, and neurosurgical procedures. A total of 383,126 pairs of systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial pressure (MAP) values from the arterial cannula and the MCCI device were analyzed. The absolute difference for SBP, DBP, and MAP values from the MCCI monitor and the arterial cannula were 10 +/- 8, 9 +/- 7, and 9 +/- 7 mm Hg, respectively. The difference between the BP values from the MCCI and the arterial cannula was <= 10 mm Hg for 60% of the SBP readings, 67% of the DBP readings, and 56% of the MAP readings. Using Bland-Altman analysis, the bias was 2, 3, and 4 mm Hg for the SBP, DBP, and MAP. Conclusions: Although there were technical limitations related to patient size that affected its ability to meet the strict accuracy criteria set by the American National Standards Institute/Association for the Advancement of Medical Instrumentation standards for noninvasive BP measurement (ANSI/AAMI SP10), the NICCI system provided a continuous noninvasive beat-to-beat BP measurement which was clinically relevant during a significant portion of intraoperative care.
引用
收藏
页码:154 / 161
页数:8
相关论文
共 50 条
  • [21] A Cluster Method to Noninvasive Continuous Blood Pressure Measurement Using PPG
    Miao, Yu
    Zhang, Zhiqiang
    Meng, Lifang
    Xie, Xiaoqin
    Pan, Haiwei
    SMART HEALTH, ICSH 2016, 2017, 10219 : 109 - 120
  • [22] Noninvasive blood pressure measurement in mice using pulsed Doppler ultrasound
    Reddy, AK
    Taffet, GE
    Madala, S
    Michael, LH
    Entman, ML
    Hartley, CJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (03): : 379 - 385
  • [23] Validation of oscillometric noninvasive blood pressure measurement devices using simulators
    Amoore, John N.
    Lemesre, Yann
    Murray, Ian C.
    Vacher, Emilie
    Mieke, Stephan
    King, Susan T.
    Smith, Fiona E.
    Murray, Alan
    BLOOD PRESSURE MONITORING, 2007, 12 (04) : 251 - 253
  • [24] Measurement of Heart Rate Variability Using an Oscillometric Blood Pressure Monitor
    Ahmad, Saif
    Bolic, Miodrag
    Dajani, Hilmi
    Groza, Voicu
    Batkin, Izmail
    Rajan, Sreeraman
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (10) : 2575 - 2590
  • [25] NONINVASIVE ARTERIAL BLOOD PRESSURE MONITOR AND POSSIBLE NERVE INJURY
    Jacobs, James O.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (08) : 2035 - 2036
  • [26] Low-cost noninvasive continuous blood pressure monitor
    de Lorena A.E.S.
    de Lima R.A.
    Malagón L.A.G.
    Research on Biomedical Engineering, 2022, 38 (02) : 559 - 570
  • [27] Intracranial Pressure: A Comparison of the Noninvasive HeadSense Monitor versus Lumbar Pressure Measurement
    Hvedstrup, Jeppe
    Radojicic, Aleksandra
    Moudrous, Walid
    Herklots, Martin Willy
    Wert, Anton
    Holzgraefe, Manfred
    Obermann, Mark
    Schoonman, Guus G.
    Jensen, Rigmor Hojland
    Schytz, Henrik Winther
    WORLD NEUROSURGERY, 2018, 112 : E576 - E580
  • [28] NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN THE NEONATE
    DARNALL, RA
    CLINICS IN PERINATOLOGY, 1985, 12 (01) : 31 - 49
  • [29] Numerical simulation of noninvasive blood pressure measurement
    Hayashi, Satoru
    Hayase, Toshiyuki
    Shirai, Atsushi
    Maruyama, Masaru
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (05): : 680 - 687
  • [30] Automatic Noninvasive Measurement of Arterial Blood Pressure
    Nitzan, Meir
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2011, 14 (01) : 32 - 37