Low-cost noninvasive continuous blood pressure monitor

被引:0
|
作者
de Lorena A.E.S. [1 ]
de Lima R.A. [1 ]
Malagón L.A.G. [1 ]
机构
[1] Polytechnic School of Pernambuco, University of Pernambuco, PE, Recife
关键词
Arduino; Bland–Altman; Blood pressure; Pearson coefficient;
D O I
10.1007/s42600-022-00207-1
中图分类号
学科分类号
摘要
Purpose: A novel design is proposed to measure the Arterial Blood Pressure (BP) using the vascular unloading technique controlling the pressure cuff acting on the air pump speed instead of a servo valve. The BP monitoring in a continuous way allows identifying the hypertension or hypotension states in order to avoid damage of vital organs such as the heart and brain in critically ill patients. Depending on the clinical evaluation, this procedure can be done invasively using an arterial catheter, or noninvasively using, for example, the volume clamp method or vascular unloading technology. In the last case, the finger BP is monitored by a photoplethysmography device coupled to an inflatable cuff controlled by a servo valve to keep constant the diameter of the artery. The cost of commercial devices using this operation principle is relatively high in comparison with noninvasive intermittent BP monitors. Method: A prototype was built based on the Arduino platform, and tested based on the International Protocol of Validation of BP Measurement Instruments in adults. As a result, a low-cost device (components cost around EUR 150) was built. Results: From the Bland–Altman analysis, the mean and standard deviation (SD) were determined as 5.09 ± 12.27 for the Systolic BP, − 1.72 ± 12.56 for the Diastolic BP, and 0.68 ± 11.08 for the Mean BP. Conclusion: Similar results were reported for commercial devices that employ the vascular unload technique controlling the cuff pressure through a servo valve. Then, the proposed device is a low-cost alternative to measure BP with results similar to commercial devices. © 2022, Sociedade Brasileira de Engenharia Biomedica.
引用
收藏
页码:559 / 570
页数:11
相关论文
共 50 条
  • [1] A Low-Cost Continuous Turbidity Monitor
    Gillett, David
    Marchiori, Alan
    [J]. SENSORS, 2019, 19 (14)
  • [2] EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITOR
    ABENSTEIN, JP
    STENSRUD, PE
    SPACKMAN, TN
    TARHAN, S
    [J]. ANESTHESIOLOGY, 1993, 79 (3A) : A504 - A504
  • [3] Validation of a novel, low-cost continuous newborn respiratory rate monitor
    Amin, A. A.
    Coyle, J.
    Oden, M.
    Richards-Kortum, R.
    Patil, M.
    [J]. AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2024, 367 : S463 - S463
  • [4] Low-cost instrument for oscillometric blood pressure measurement
    Wongjan, Anan
    Julsereewong, Prasit
    Julsereewong, Amphawan
    [J]. ICIC Express Letters, Part B: Applications, 2015, 6 (05): : 1259 - 1265
  • [5] tinyCare: A tinyML-based Low-Cost Continuous Blood Pressure Estimation on the Extreme Edge
    Ahmed, Khaled
    Hassan, Mohamed
    [J]. 2022 IEEE 10TH INTERNATIONAL CONFERENCE ON HEALTHCARE INFORMATICS (ICHI 2022), 2022, : 264 - 275
  • [6] A low-cost microsystem for noninvasive uroflowmetry
    Viarani, Nicola
    Massari, Nicola
    Gottardi, Massimo
    Simoni, Andrea
    Margesin, Benno
    Faes, Alessandro
    Decarli, Massimiliano
    Guarnieri, Vittorio
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2006, 55 (03) : 964 - 971
  • [7] Dialysis monitor and low-cost haemodialysis
    Touam, Malik
    Luong, Nhan
    Man, Nguyen Khoa
    [J]. NEPHROLOGIE & THERAPEUTIQUE, 2019, 15 : S109 - S113
  • [8] IS A LOW-COST COLOR MONITOR COMING
    COHEN, CL
    [J]. ELECTRONICS, 1987, 60 (10): : 32 - 33
  • [9] LOW-COST RESISTANCE WELDING MONITOR
    ANDREWS, DR
    DUNN, A
    BROOMHEAD, J
    [J]. METAL CONSTRUCTION, 1976, 8 (07): : 309 - 310
  • [10] ASSESSMENT OF CORTRONIC APM-770, A NONINVASIVE CONTINUOUS BLOOD-PRESSURE MONITOR
    CARAMELLA, JP
    HIDOU, M
    CLAUDE, E
    [J]. ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1991, 10 (05): : 425 - 429