Low-cost noninvasive continuous blood pressure monitor

被引:0
|
作者
de Lorena A.E.S. [1 ]
de Lima R.A. [1 ]
Malagón L.A.G. [1 ]
机构
[1] Polytechnic School of Pernambuco, University of Pernambuco, PE, Recife
关键词
Arduino; Bland–Altman; Blood pressure; Pearson coefficient;
D O I
10.1007/s42600-022-00207-1
中图分类号
学科分类号
摘要
Purpose: A novel design is proposed to measure the Arterial Blood Pressure (BP) using the vascular unloading technique controlling the pressure cuff acting on the air pump speed instead of a servo valve. The BP monitoring in a continuous way allows identifying the hypertension or hypotension states in order to avoid damage of vital organs such as the heart and brain in critically ill patients. Depending on the clinical evaluation, this procedure can be done invasively using an arterial catheter, or noninvasively using, for example, the volume clamp method or vascular unloading technology. In the last case, the finger BP is monitored by a photoplethysmography device coupled to an inflatable cuff controlled by a servo valve to keep constant the diameter of the artery. The cost of commercial devices using this operation principle is relatively high in comparison with noninvasive intermittent BP monitors. Method: A prototype was built based on the Arduino platform, and tested based on the International Protocol of Validation of BP Measurement Instruments in adults. As a result, a low-cost device (components cost around EUR 150) was built. Results: From the Bland–Altman analysis, the mean and standard deviation (SD) were determined as 5.09 ± 12.27 for the Systolic BP, − 1.72 ± 12.56 for the Diastolic BP, and 0.68 ± 11.08 for the Mean BP. Conclusion: Similar results were reported for commercial devices that employ the vascular unload technique controlling the cuff pressure through a servo valve. Then, the proposed device is a low-cost alternative to measure BP with results similar to commercial devices. © 2022, Sociedade Brasileira de Engenharia Biomedica.
引用
收藏
页码:559 / 570
页数:11
相关论文
共 50 条
  • [31] LOW-COST CONTINUOUS COMPRESSION MEASUREMENT
    ENGELMAN, HW
    [J]. MECHANICAL ENGINEERING, 1974, 96 (08): : 59 - 59
  • [32] An Integrated Biosignals Wearable System for Low-Cost Blood Pressure Monitoring
    Almahouzi, Amnyah
    Alnaser, Toka
    Tiraei, Susanne
    Athavale, Yashodhan
    Krishnan, Sridhar
    [J]. 2017 IEEE CANADA INTERNATIONAL HUMANITARIAN TECHNOLOGY CONFERENCE (IHTC), 2017,
  • [33] EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITOR IN OBSTETRIC PATIENTS UNDERGOING SPINAL-ANESTHESIA
    EPSTEIN, RH
    KAPLAN, S
    LEIGHTON, BL
    NORRIS, MC
    DESIMONE, CA
    [J]. JOURNAL OF CLINICAL MONITORING, 1989, 5 (03): : 157 - 163
  • [34] CONTINUOUS, REAL-TIME, NONINVASIVE MONITOR OF BLOOD-PRESSURE - PENAZ METHODOLOGY APPLIED TO THE FINGER
    BOEHMER, RD
    [J]. JOURNAL OF CLINICAL MONITORING, 1987, 3 (04): : 282 - 287
  • [35] A low-cost solar-powered blood-pressure device
    Sliwa, Karen
    Stewart, Simon
    [J]. LANCET, 2011, 378 (9792): : 647 - 648
  • [36] An Integrated Biosignals Wearable System for Low-Cost Blood Pressure Monitoring
    Almahouzi, Amnyah
    Alnaser, Toka
    Tiraei, Susanne
    Athavale, Yashodhan
    Krishnan, Sridhar
    [J]. 2017 IEEE CANADA INTERNATIONAL HUMANITARIAN TECHNOLOGY CONFERENCE (IHTC), 2017,
  • [37] Development of Portable ECG Monitor On Low-cost DSP
    Qi, Lin
    Zhang, Yonghong
    Bai, Jing
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 4058 - 4060
  • [38] A low-cost on-board vehicle load monitor
    Lacquet, BM
    Swart, PL
    Kotze, AP
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (12) : 1761 - 1765
  • [39] Low-cost power quality monitor based on a PC
    Batista, J
    Afonso, JL
    Martins, JS
    [J]. 2003 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1 AND 2, 2003, : 323 - 328
  • [40] A low-cost, compact indoor thermal environment monitor
    Chen, S
    Watanabe, K
    Nakayama, M
    Kanehori, M
    Okuyama, H
    Ito, Y
    Kushime, E
    [J]. IMTC/2000: PROCEEDINGS OF THE 17TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE: SMART CONNECTIVITY: INTEGRATING MEASUREMENT AND CONTROL, 2000, : 290 - 294