Low-cost noninvasive continuous blood pressure monitor

被引:0
|
作者
de Lorena A.E.S. [1 ]
de Lima R.A. [1 ]
Malagón L.A.G. [1 ]
机构
[1] Polytechnic School of Pernambuco, University of Pernambuco, PE, Recife
关键词
Arduino; Bland–Altman; Blood pressure; Pearson coefficient;
D O I
10.1007/s42600-022-00207-1
中图分类号
学科分类号
摘要
Purpose: A novel design is proposed to measure the Arterial Blood Pressure (BP) using the vascular unloading technique controlling the pressure cuff acting on the air pump speed instead of a servo valve. The BP monitoring in a continuous way allows identifying the hypertension or hypotension states in order to avoid damage of vital organs such as the heart and brain in critically ill patients. Depending on the clinical evaluation, this procedure can be done invasively using an arterial catheter, or noninvasively using, for example, the volume clamp method or vascular unloading technology. In the last case, the finger BP is monitored by a photoplethysmography device coupled to an inflatable cuff controlled by a servo valve to keep constant the diameter of the artery. The cost of commercial devices using this operation principle is relatively high in comparison with noninvasive intermittent BP monitors. Method: A prototype was built based on the Arduino platform, and tested based on the International Protocol of Validation of BP Measurement Instruments in adults. As a result, a low-cost device (components cost around EUR 150) was built. Results: From the Bland–Altman analysis, the mean and standard deviation (SD) were determined as 5.09 ± 12.27 for the Systolic BP, − 1.72 ± 12.56 for the Diastolic BP, and 0.68 ± 11.08 for the Mean BP. Conclusion: Similar results were reported for commercial devices that employ the vascular unload technique controlling the cuff pressure through a servo valve. Then, the proposed device is a low-cost alternative to measure BP with results similar to commercial devices. © 2022, Sociedade Brasileira de Engenharia Biomedica.
引用
收藏
页码:559 / 570
页数:11
相关论文
共 50 条
  • [41] Development of a low-cost monitor for radon detection in air
    Elisio, Soraia
    Peralta, Luis
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 969 (969):
  • [42] Stress Testing of a Low-Cost GNSS RFI Monitor
    Stanford University, United States
    不详
    [J]. Int. Tech. Meet. Satell. Div. Inst. Navig., ION GNSS+, (3431-3446): : 3431 - 3446
  • [43] LOW-COST PERFORMANCE MONITOR FOR POWER-PLANTS
    PICK, RW
    [J]. POWER ENGINEERING, 1990, 94 (02) : 37 - 40
  • [44] A LOW-COST ION-BEAM PROFILE MONITOR
    GODFREY, L
    HOYES, GG
    PAIRSUWAN, W
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 51 (03): : 294 - 300
  • [45] NONINVASIVE ARTERIAL BLOOD PRESSURE MONITOR AND POSSIBLE NERVE INJURY
    Jacobs, James O.
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (08) : 2035 - 2036
  • [46] Low-Cost Photoreactor to Monitor Wastewater Pollutant Decomposition
    Ruiz-Flores, Alberto
    Garcia, Araceli
    Pineda, Antonio
    Brox, Maria
    Gersnoviez, Andres
    Canete-Carmona, Eduardo
    [J]. SENSORS, 2023, 23 (02)
  • [47] Development of a low-cost textile sensor based insole to monitor foot pressure of diabetic patients
    Alam, Nuzat Nuary
    Faiz, Rethwan
    Imam, Mohammad Hasan
    [J]. Journal of Medical Engineering and Technology, 2022, 46 (04): : 288 - 299
  • [48] Measurement of Central Systolic Blood Pressure by Pulse Volume Plethysmography With a Noninvasive Blood Pressure Monitor
    Sung, Shih-Hsien
    Cheng, Hao-Min
    Chuang, Shao-Yuan
    Shih, Yuan-Ta
    Wang, Kang-Ling
    Chen, Ying-Hwa
    Lin, Shing-Jong
    Yu, Wen-Chung
    Chen, Chen-Huan
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2012, 25 (05) : 542 - 548
  • [49] An Evaluation of the NICCI Monitor in Providing Continuous, Noninvasive Blood Pressure Readings in Children During Intraoperative Anesthetic Care
    Bekiroglu, Ismail
    Owusu-Bediako, Kwaku
    Rice-Weimer, Julie
    Tobias, Joseph D.
    [J]. JOURNAL OF CLINICAL MEDICINE RESEARCH-CANADA, 2022, 14 (04): : 158 - 164
  • [50] THE UPGRADED FINAPRES-2300E - A CLINICAL-EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITOR
    JONES, RDM
    BROWN, AG
    ROULSON, CJ
    SMITH, ID
    CHAN, SC
    [J]. ANAESTHESIA, 1992, 47 (08) : 701 - 705