THE UPGRADED FINAPRES-2300E - A CLINICAL-EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITOR

被引:27
|
作者
JONES, RDM [1 ]
BROWN, AG [1 ]
ROULSON, CJ [1 ]
SMITH, ID [1 ]
CHAN, SC [1 ]
机构
[1] UNIV HONG KONG, ELECTR SERV UNIT, HONG KONG, HONG KONG
关键词
BLOOD PRESSURE; MEASUREMENT; MONITORING; NONINVASIVE; EQUIPMENT; FINAPRES;
D O I
10.1111/j.1365-2044.1992.tb02396.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Measurements from the upgraded Finapres 2300e continuous noninvasive blood pressure monitor, the Finapres 2300 and Colin oscillometric noninvasive blood pressure monitor were compared with invasive arterial line blood pressure readings. Fifteen young Chinese patients undergoing elective spinal surgery of more than 2 h duration had contemporaneous blood pressure measurements digitally recorded every minute. Data were analysed using methods described by Bland and Altman to assess agreement of noninvasive devices with an arterial line. Results showed that although the Finapres 2300e was significantly more accurate than the Finapres 2300 and Colin noninvasive blood pressure monitors it could not be recommended as a substitute for continuous arterial line blood pressure monitoring. Both Finapres devices demonstrated reductions in accuracy related to time (drift) and over‐read diastolic and mean pressures by 5–8 mmHg throughout the range of mean arterial line pressures (bias). The Colin was consistently less accurate than the Finapress monitors and performed worst at low mean arterial line pressures. Copyright © 1992, Wiley Blackwell. All rights reserved
引用
收藏
页码:701 / 705
页数:5
相关论文
共 50 条
  • [1] FINAPRES - A NONINVASIVE DEVICE TO MONITOR BLOOD-PRESSURE
    PORTER, KB
    OBRIEN, WF
    KIEFERT, V
    KNUPPEL, RA
    OBSTETRICS AND GYNECOLOGY, 1991, 78 (03): : 430 - 433
  • [2] EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITOR
    ABENSTEIN, JP
    STENSRUD, PE
    SPACKMAN, TN
    TARHAN, S
    ANESTHESIOLOGY, 1993, 79 (3A) : A504 - A504
  • [3] CLINICAL-EVALUATION OF CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITORING - ACCURACY AND TRACKING CAPABILITIES
    YOUNG, CC
    MARK, JB
    WHITE, W
    DEBREE, A
    VENDER, JS
    FLEMING, A
    JOURNAL OF CLINICAL MONITORING, 1995, 11 (04): : 245 - 252
  • [4] CLINICAL-EVALUATION OF THE CALIBRATION OF NONINVASIVE CONTINUOUS BLOOD-PRESSURE MEASUREMENT DEVICES BY MEANS OF OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENTS
    DEJONG, JR
    ROS, HH
    DELANGE, JJ
    BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 : 8 - 8
  • [5] NONINVASIVE CONTINUOUS BLOOD-PRESSURE MEASUREMENT - A CLINICAL-EVALUATION OF THE CORTRONIC APM-770
    DEJONG, JR
    TEPASKE, R
    SCHEFFER, GJ
    ROS, HH
    SIPKEMA, PP
    DELANGE, JJ
    JOURNAL OF CLINICAL MONITORING, 1993, 9 (01): : 18 - 24
  • [6] A CLINICAL-EVALUATION OF THE ACCUTRACKER - A LIGHTWEIGHT AMBULATORY BLOOD-PRESSURE MONITOR
    PHILLIPS, DIW
    BRAITHWAITE, J
    NEWCOMBE, RG
    LAZARUS, JH
    JOURNAL OF HUMAN HYPERTENSION, 1989, 3 (06) : 463 - 465
  • [7] CLINICAL-EVALUATION OF THE SPHYGMOMAT-2 SEMIAUTOMATIC BLOOD-PRESSURE MONITOR
    PRIOR, AJ
    PECK, K
    DAVIES, P
    BEEVERS, DG
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1990, 14 (06) : 250 - 253
  • [8] CLINICAL-EVALUATION OF THE INFRASONDE-D4000 BLOOD-PRESSURE MONITOR
    ZEZULKA, AV
    SLOAN, PJM
    DAVIES, P
    BEEVERS, DG
    POSTGRADUATE MEDICAL JOURNAL, 1985, 61 (714) : 321 - 323
  • [9] MORBIDITY AFTER USE OF THE FINAPRES BLOOD-PRESSURE MONITOR
    NORTHWOOD, D
    ANAESTHESIA, 1989, 44 (12) : 1010 - 1011
  • [10] CLINICAL-EVALUATION OF BLOOD-PRESSURE IN ALCOHOLICS
    SCHNALL, C
    WIENER, JS
    QUARTERLY JOURNAL OF STUDIES ON ALCOHOL, 1958, 19 (03): : 432 - 446