THE UPGRADED FINAPRES-2300E - A CLINICAL-EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITOR

被引:27
|
作者
JONES, RDM [1 ]
BROWN, AG [1 ]
ROULSON, CJ [1 ]
SMITH, ID [1 ]
CHAN, SC [1 ]
机构
[1] UNIV HONG KONG, ELECTR SERV UNIT, HONG KONG, HONG KONG
关键词
BLOOD PRESSURE; MEASUREMENT; MONITORING; NONINVASIVE; EQUIPMENT; FINAPRES;
D O I
10.1111/j.1365-2044.1992.tb02396.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Measurements from the upgraded Finapres 2300e continuous noninvasive blood pressure monitor, the Finapres 2300 and Colin oscillometric noninvasive blood pressure monitor were compared with invasive arterial line blood pressure readings. Fifteen young Chinese patients undergoing elective spinal surgery of more than 2 h duration had contemporaneous blood pressure measurements digitally recorded every minute. Data were analysed using methods described by Bland and Altman to assess agreement of noninvasive devices with an arterial line. Results showed that although the Finapres 2300e was significantly more accurate than the Finapres 2300 and Colin noninvasive blood pressure monitors it could not be recommended as a substitute for continuous arterial line blood pressure monitoring. Both Finapres devices demonstrated reductions in accuracy related to time (drift) and over‐read diastolic and mean pressures by 5–8 mmHg throughout the range of mean arterial line pressures (bias). The Colin was consistently less accurate than the Finapress monitors and performed worst at low mean arterial line pressures. Copyright © 1992, Wiley Blackwell. All rights reserved
引用
收藏
页码:701 / 705
页数:5
相关论文
共 50 条
  • [21] EVALUATION OF THE SUNTECH ACCUTRACKER - A NOVEL NONINVASIVE AMBULATORY BLOOD-PRESSURE MONITOR
    NELSON, KS
    WEBER, RR
    ELLIOTT, WJ
    ZEBRAUSKAS, D
    MURPHY, MB
    AMERICAN JOURNAL OF HYPERTENSION, 1988, 1 (03) : S121 - S123
  • [22] ASSESSMENT OF CORTRONIC APM-770, A NONINVASIVE CONTINUOUS BLOOD-PRESSURE MONITOR
    CARAMELLA, JP
    HIDOU, M
    CLAUDE, E
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1991, 10 (05): : 425 - 429
  • [23] CONTINUOUS DIRECT AND INDIRECT BLOOD-PRESSURE MEASUREMENT (FINAPRES) IN THE CRITICALLY ILL
    FARQUHAR, IK
    ANAESTHESIA, 1991, 46 (12) : 1050 - 1055
  • [24] Noninvasive measurement of blood pressure variability: accuracy of the Finometer monitor and comparison with the Finapres device
    Maestri, R
    Pinna, GD
    Robbi, E
    Capomolla, S
    La Rovere, MT
    PHYSIOLOGICAL MEASUREMENT, 2005, 26 (06) : 1125 - 1136
  • [25] MULTICENTER EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITORING-SYSTEM
    YOUNG, C
    VENDER, J
    FLEMING, A
    DEBREE, A
    WHITE, W
    ANESTHESIOLOGY, 1993, 79 (3A) : A501 - A501
  • [26] A CLINICAL-EVALUATION OF RAPID AUTOMATIC NONINVASIVE BLOOD-PRESSURE DETERMINATION WITH THE OHMEDA 2120 RETURN-TO-FLOW METHOD
    BLOCK, FE
    FLETCHER, MV
    MORRIS, TJ
    DZWONCZYK, R
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (03): : 241 - 244
  • [27] NONINVASIVE, CONTINUOUS BLOOD-PRESSURE MEASUREMENT IN PSYCHOPHYSIOLOGY
    GODAERT, G
    KRUITWAGEN, J
    JASPERS, J
    PSYCHOPHYSIOLOGY, 1985, 22 (05) : 591 - 592
  • [28] AUTOMATIC BLOOD-PRESSURE MONITORS - A CLINICAL-EVALUATION OF 5 MODELS IN ADULTS
    JOHNSON, CJH
    KERR, JH
    ANAESTHESIA, 1985, 40 (05) : 471 - 478
  • [29] CLINICAL-EVALUATION OF DINAMAP-845 AUTOMATED BLOOD-PRESSURE RECORDER
    SILAS, JH
    BARKER, AT
    RAMSAY, LE
    BRITISH HEART JOURNAL, 1980, 43 (02): : 202 - 205
  • [30] CLINICAL-EVALUATION OF SEMIAUTOMATIC BLOOD-PRESSURE DEVICES FOR SELF-RECORDING
    STEINER, R
    LUSCHER, T
    BOERLIN, HJ
    SIEGENTHALER, W
    VETTER, W
    JOURNAL OF HYPERTENSION, 1985, 3 : 23 - 25