Design of a 3D printed coronary artery model for CT optimization

被引:16
|
作者
Morup, S. D. [1 ,2 ,3 ]
Stowe, J. [3 ]
Precht, H. [1 ,4 ,5 ]
Gervig, M. H. [1 ]
Foley, S. [3 ]
机构
[1] UCL Univ Coll, Hlth Sci Res Ctr, Niels Bohrs Alle 1, DK-5230 Odense M, Denmark
[2] Odense Univ Hosp, Cardiol Res Dept, Baagoes Alle 15, DK-5700 Svendborg, Denmark
[3] Univ Coll Dublin, Sch Med, Radiog & Diagnost Imaging, Dublin, Ireland
[4] Univ Southern Denmark, Dept Clin Res, Winslowspk 5000, DK-5000 Odense C, Denmark
[5] Hosp Little Belt Kolding, Dept Radiol, Kolding, Denmark
关键词
Computed tomography; Phantom; Three-dimensional printing; Iterative reconstruction; Image quality; Patient safety;
D O I
10.1016/j.radi.2021.09.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: To design a custom phantom of the coronary arteries to optimize CT coronary angiography (CCTA) protocols. Methods: Characteristics of the left and right coronary arteries (mean Hounsfield Unit (HU) values and diameters) were collected from consecutive CCTA examinations (n 1/4 43). Four different materials (two mixtures of glycerine, gelatine and water, pig hearts, EcoflexTM silicone) were scanned inside a Lungman phantom using the CCTA protocol to find the closest model to in vivo data. A 3D printed model of the coronary artery tree was created using CCTA data by exporting a CT volume rendering into Autodesk MeshmixerTM software. The model was placed in an acid bath for 5 h, then covered in EcoflexTM, which was removed after drying. Both the EcoflexTM and pig heart were later filled with a mixture of contrast (Visipaque 320 mg I/ml), NaCl and gelatin and scanned with different levels of tube current and iterative reconstruction (ASiR-V). Objective (HU, noise and size (vessel diameter) and subjective analysis were performed on all scans. Results: The gelatine mixtures had HU values of 130 and 129, EcoflexTM 65 and the pig heart 56. At the different mA/ASiR-V levels the contrast filled EcoflexTM had a mean HU 318 +/- 4, noise 47 +/- 7HU and diameter of 4.4 mm. The pig heart had a mean HU of 209 +/- 5, noise 38 +/- 4HU and a diameter of 4.4 mm. With increasing iterative reconstruction level the visualisation of the pig heart arteries decreased so no measurements could be performed. Conclusion: The use of a 3D printed model of the arteries and casting with the EcoflexTM silicone is the most suitable solution for a custom-designed phantom. Implications for practice: Custom designed phantoms using 3D printing technology enable cost effective optimisation of CT protocols. (c) 2021 The College of Radiographers. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:426 / 432
页数:7
相关论文
共 50 条
  • [21] Advanced 3D printed model of middle cerebral artery aneurysms for neurosurgery simulation
    Nagassa, Ruth G.
    McMenamin, Paul G.
    Adams, Justin W.
    Quayle, Michelle R.
    Rosenfeld, Jeffrey V.
    3D PRINTING IN MEDICINE, 2019, 5 (01)
  • [22] Design, optimization, simulation, and implementation of a 3D printed soft robotic peristaltic pump
    Totuk, Onat Halis
    Mistikoglu, Selcuk
    Guvenc, Mehmet Ali
    ENGINEERING RESEARCH EXPRESS, 2024, 6 (04):
  • [23] DESIGN AND VALIDATION OF 3D PRINTED MODEL FOR BURCH COLPOSUSPENSION AND PARAVAGINAL REPAIR
    Gangal, M.
    NEUROUROLOGY AND URODYNAMICS, 2015, 34 : S258 - S258
  • [24] Creation of a 3D printed temporal bone model from clinical CT data
    Cohen, Joss
    Reyes, Samuel A.
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2015, 36 (05) : 619 - 624
  • [25] Material Saving Optimization of 3D Printed Objects
    Liu, Bin (mold_bin@hqu.edu.cn), 1600, Institute of Computing Technology (29):
  • [26] Hemodynamic study in 3D printed stenotic coronary artery models: experimental validation and transient simulation
    Carvalho, Violeta
    Rodrigues, Nelson
    Ribeiro, Ricardo
    Costa, Pedro F.
    Teixeira, Jose C. F.
    Lima, Rui A.
    Teixeira, Senhorinha F. C. F.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (06) : 623 - 636
  • [27] 3D printed personalized, heparinized and biodegradable coronary artery stents for rabbit abdominal aorta implantation
    Shen, Yihong
    Tang, Chaojie
    Sun, Binbin
    Zhang, Yang
    Sun, Xiaolin
    EL-Newehy, Mohamed
    EL-Hamshary, Hany
    Morsi, Yosry
    Gu, Hongbing
    Wang, Wu
    Mo, Xiumei
    CHEMICAL ENGINEERING JOURNAL, 2022, 450
  • [28] 3D Printed Fabric: Techniques for Design and 3D Weaving Programmable Textiles
    Takahashi, Haruki
    Kim, Jeeeun
    PROCEEDINGS OF THE 32ND ANNUAL ACM SYMPOSIUM ON USER INTERFACE SOFTWARE AND TECHNOLOGY (UIST 2019), 2019, : 43 - 51
  • [29] Automatic Assessment of 3D Coronary Artery Distensibility from Time-Resolved Coronary CT Angiography
    Ghanem, Ahmed M.
    Hamimi, Ahmed H.
    Gharib, Ahmed M.
    Abd-Elmoniem, Khaled Z.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 836 - 840
  • [30] 3D RRAM: DESIGN AND OPTIMIZATION
    Kang, Jinfeng
    Gao, Bin
    Chen, B.
    Huang, P.
    Zhang, F. F.
    Deng, Y. X.
    Liu, L. F.
    Liu, X. Y.
    Chen, H-Y.
    Jiang, Z.
    Yu, S. M.
    Wong, H-S Philip
    2014 12TH IEEE INTERNATIONAL CONFERENCE ON SOLID-STATE AND INTEGRATED CIRCUIT TECHNOLOGY (ICSICT), 2014,