Design of a 3D printed coronary artery model for CT optimization

被引:16
|
作者
Morup, S. D. [1 ,2 ,3 ]
Stowe, J. [3 ]
Precht, H. [1 ,4 ,5 ]
Gervig, M. H. [1 ]
Foley, S. [3 ]
机构
[1] UCL Univ Coll, Hlth Sci Res Ctr, Niels Bohrs Alle 1, DK-5230 Odense M, Denmark
[2] Odense Univ Hosp, Cardiol Res Dept, Baagoes Alle 15, DK-5700 Svendborg, Denmark
[3] Univ Coll Dublin, Sch Med, Radiog & Diagnost Imaging, Dublin, Ireland
[4] Univ Southern Denmark, Dept Clin Res, Winslowspk 5000, DK-5000 Odense C, Denmark
[5] Hosp Little Belt Kolding, Dept Radiol, Kolding, Denmark
关键词
Computed tomography; Phantom; Three-dimensional printing; Iterative reconstruction; Image quality; Patient safety;
D O I
10.1016/j.radi.2021.09.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: To design a custom phantom of the coronary arteries to optimize CT coronary angiography (CCTA) protocols. Methods: Characteristics of the left and right coronary arteries (mean Hounsfield Unit (HU) values and diameters) were collected from consecutive CCTA examinations (n 1/4 43). Four different materials (two mixtures of glycerine, gelatine and water, pig hearts, EcoflexTM silicone) were scanned inside a Lungman phantom using the CCTA protocol to find the closest model to in vivo data. A 3D printed model of the coronary artery tree was created using CCTA data by exporting a CT volume rendering into Autodesk MeshmixerTM software. The model was placed in an acid bath for 5 h, then covered in EcoflexTM, which was removed after drying. Both the EcoflexTM and pig heart were later filled with a mixture of contrast (Visipaque 320 mg I/ml), NaCl and gelatin and scanned with different levels of tube current and iterative reconstruction (ASiR-V). Objective (HU, noise and size (vessel diameter) and subjective analysis were performed on all scans. Results: The gelatine mixtures had HU values of 130 and 129, EcoflexTM 65 and the pig heart 56. At the different mA/ASiR-V levels the contrast filled EcoflexTM had a mean HU 318 +/- 4, noise 47 +/- 7HU and diameter of 4.4 mm. The pig heart had a mean HU of 209 +/- 5, noise 38 +/- 4HU and a diameter of 4.4 mm. With increasing iterative reconstruction level the visualisation of the pig heart arteries decreased so no measurements could be performed. Conclusion: The use of a 3D printed model of the arteries and casting with the EcoflexTM silicone is the most suitable solution for a custom-designed phantom. Implications for practice: Custom designed phantoms using 3D printing technology enable cost effective optimisation of CT protocols. (c) 2021 The College of Radiographers. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:426 / 432
页数:7
相关论文
共 50 条
  • [31] 3D printed coronary models offer new opportunities for developing optimal coronary CT angiography protocols in imaging coronary stents
    Sun, Zhonghua
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (08) : 1350 - 1355
  • [32] Design of a 3D printed concrete bridge by testing
    Salet, Theo A. M.
    Ahmed, Zeeshan Y.
    Bos, Freek P.
    Laagland, Hans L. M.
    VIRTUAL AND PHYSICAL PROTOTYPING, 2018, 13 (03) : 222 - 236
  • [33] Design characterization of 3D printed compliant gripper
    Mayyas, Mohammad
    MECCANICA, 2022, 57 (03) : 723 - 738
  • [34] Exploring Design Approaches for 3D Printed Antennas
    Carvalho, Saul S.
    Reis, Joao R. V.
    Mateus, Artur
    Caldeirinha, Rafael F. S.
    IEEE ACCESS, 2024, 12 : 10718 - 10735
  • [35] Design characterization of 3D printed compliant gripper
    Mohammad Mayyas
    Meccanica, 2022, 57 : 723 - 738
  • [36] Preliminary design of 3D printed fittings for UAV
    Mieloszyk, Jacek
    Tarnowski, Andrzej
    Kowalik, Michal
    Perz, Rafal
    Rzadkowski, Witold
    AIRCRAFT ENGINEERING AND AEROSPACE TECHNOLOGY, 2019, 91 (05): : 756 - 760
  • [37] Design of a Compact 3D Printed Coaxial Filter
    Venanzoni, Giuseppe
    Dionigi, Marco
    Tomassoni, Cristiano
    Sorrentino, Roberto
    2018 48TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2018, : 280 - 283
  • [38] Design and Realization of 3D Printed AFM Probes
    Alsharif, Nourin
    Burkatovsky, Anna
    Lissandrello, Charles
    Jones, Keith M.
    White, Alice E.
    Brown, Keith A.
    SMALL, 2018, 14 (19)
  • [39] 3D printed electrodes design and voltammetric response
    Veloso, William B.
    Paixao, Thiago R. L. C.
    Meloni, Gabriel N.
    ELECTROCHIMICA ACTA, 2023, 449
  • [40] Design of 3D Printed Plastic Modular Filters
    Saucourt, Jeremy
    Jolly, Nicolas
    Perigaud, Aurelien
    Tantot, Olivier
    Delhote, Nicolas
    Bila, Staphane
    Verdeyme, Serge
    2016 46TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2016, : 365 - 368