Design of a 3D printed coronary artery model for CT optimization

被引:16
|
作者
Morup, S. D. [1 ,2 ,3 ]
Stowe, J. [3 ]
Precht, H. [1 ,4 ,5 ]
Gervig, M. H. [1 ]
Foley, S. [3 ]
机构
[1] UCL Univ Coll, Hlth Sci Res Ctr, Niels Bohrs Alle 1, DK-5230 Odense M, Denmark
[2] Odense Univ Hosp, Cardiol Res Dept, Baagoes Alle 15, DK-5700 Svendborg, Denmark
[3] Univ Coll Dublin, Sch Med, Radiog & Diagnost Imaging, Dublin, Ireland
[4] Univ Southern Denmark, Dept Clin Res, Winslowspk 5000, DK-5000 Odense C, Denmark
[5] Hosp Little Belt Kolding, Dept Radiol, Kolding, Denmark
关键词
Computed tomography; Phantom; Three-dimensional printing; Iterative reconstruction; Image quality; Patient safety;
D O I
10.1016/j.radi.2021.09.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: To design a custom phantom of the coronary arteries to optimize CT coronary angiography (CCTA) protocols. Methods: Characteristics of the left and right coronary arteries (mean Hounsfield Unit (HU) values and diameters) were collected from consecutive CCTA examinations (n 1/4 43). Four different materials (two mixtures of glycerine, gelatine and water, pig hearts, EcoflexTM silicone) were scanned inside a Lungman phantom using the CCTA protocol to find the closest model to in vivo data. A 3D printed model of the coronary artery tree was created using CCTA data by exporting a CT volume rendering into Autodesk MeshmixerTM software. The model was placed in an acid bath for 5 h, then covered in EcoflexTM, which was removed after drying. Both the EcoflexTM and pig heart were later filled with a mixture of contrast (Visipaque 320 mg I/ml), NaCl and gelatin and scanned with different levels of tube current and iterative reconstruction (ASiR-V). Objective (HU, noise and size (vessel diameter) and subjective analysis were performed on all scans. Results: The gelatine mixtures had HU values of 130 and 129, EcoflexTM 65 and the pig heart 56. At the different mA/ASiR-V levels the contrast filled EcoflexTM had a mean HU 318 +/- 4, noise 47 +/- 7HU and diameter of 4.4 mm. The pig heart had a mean HU of 209 +/- 5, noise 38 +/- 4HU and a diameter of 4.4 mm. With increasing iterative reconstruction level the visualisation of the pig heart arteries decreased so no measurements could be performed. Conclusion: The use of a 3D printed model of the arteries and casting with the EcoflexTM silicone is the most suitable solution for a custom-designed phantom. Implications for practice: Custom designed phantoms using 3D printing technology enable cost effective optimisation of CT protocols. (c) 2021 The College of Radiographers. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:426 / 432
页数:7
相关论文
共 50 条
  • [41] Design and analysis of 3D printed UAV wheel
    Vashi, Yash
    Anand, Raunika
    Jayakrishna, K.
    Rajyalakshmi, G.
    Raj, S. Aravind
    MATERIALS TODAY-PROCEEDINGS, 2021, 46 : 8307 - 8312
  • [42] Registration of 3D CT angiography and cardiac MR images in coronary artery disease patients
    Sturm, B
    Powell, KA
    Stillman, AE
    White, RD
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2003, 19 (04): : 281 - 293
  • [43] Registration of 3D CT angiography and cardiac MR images in coronary artery disease patients
    Bernhard Sturm
    Kimerly A. Powell
    Arthur E. Stillman
    Richard D. White
    The International Journal of Cardiovascular Imaging, 2003, 19 : 281 - 293
  • [44] A 3D PRINTED TRAINING MODEL FOR CHOLECYSTECTOMY INCORPORATING THE "MOYNIHAN HUMP" ORIGIN OF THE CYSTIC ARTERY
    Singaravelu, A.
    Myles, C.
    Gorman, Singaravelu A.
    Myles, C.
    Gorman, L.
    Campbell, T.
    Brougham, D. F.
    Jones, J. F. X.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2023, 192 (SUPPL 1) : S11 - S11
  • [45] Topology and Geometry Optimization for Design of a 3D Printed Compliant Constant-Force Mechanism
    Liu, Chih-Hsing
    Hsu, Mao-Cheng
    Chen, Ta-Lun
    2020 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2020, : 553 - 558
  • [46] Architectural design and optimization of internal structures in 3D printed electrodes for superior supercapacitor performance
    Gu, Shunyu
    Du, Guangyu
    Su, Yichun
    Zhang, Yanfei
    Zhang, Yuan
    Li, Lvzhou
    Pang, Huan
    Zhou, Huijie
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2025, 677 : 21 - 29
  • [47] Optimization of 3D Reconstruction Technique for CT Image and Analysis of The Derived Model
    Jin Zhao
    Yuan Guoqiang
    Liu Hui
    2017 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE AND ENGINEERING (CSE) AND IEEE/IFIP INTERNATIONAL CONFERENCE ON EMBEDDED AND UBIQUITOUS COMPUTING (EUC), VOL 1, 2017, : 875 - 878
  • [48] A 3D printed plant model for accurate and reliable 3D plant phenotyping
    Boemer, Jonas
    Esser, Felix
    Marks, Elias
    Rosu, Radu Alexandru
    Behnke, Sven
    Klingbeil, Lasse
    Kuhlmann, Heiner
    Stachniss, Cyrill
    Mahlein, Anne-Katrin
    Paulus, Stefan
    GIGASCIENCE, 2024, 13
  • [49] Automatic generation of 3D coronary artery centerlines
    Jandt, Uwe
    Schaefer, Dirk
    Rasche, Volker
    Grass, Michael
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [50] 3D Printed
    Good, Andrew
    MATERIALS EVALUATION, 2016, 74 (07) : 984 - 989