Analytical model for dental implant insertion torque

被引:7
|
作者
Yang, Baixuan [1 ]
Irastorza-Landa, Ainara [2 ]
Heuberger, Peter [2 ]
Ploeg, Heidi-Lynn [1 ]
机构
[1] Queens Univ Kingston, Dept Mech & Mat Engn, McLaughlin Hall,130 Stuart St, Kingston, ON K7L 3N6, Canada
[2] Nobel Biocare Serv AG, Balz Zimmermann Str 7, CH-8302 Kloten, Switzerland
基金
加拿大自然科学与工程研究理事会;
关键词
Dental implant; Torque; Model; PRIMARY STABILITY; BONE-DENSITY; OSSEOINTEGRATION; MECHANICS;
D O I
10.1016/j.jmbbm.2022.105223
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Maximum insertion torque (IT) for threaded dental implants is a primary clinical measurement to assess implant anchorage, and strongly influences the clinical outcome. Insertion torque is influenced by surgical technique, implant designs, and patient factors such as bone density and quality. In this study, an analytical model was proposed for IT to estimate contributions from the thread and taper separately. The purpose of this study was to test if the analytical model could 1. differentiate the parallel-walled and tapered implant; and, 2. represent four factors: bone surrogate density, drill protocol, implant surface finish and cutting flute. The IT was modeled as the sum of the torques from the thread's inclined plane and interface shear stress from the tapered body integrated over the surface area, respectively, with two main parameters: effective force, F ', F ' and effective pressure, p '. The effective force, relates to the clamping force from the thread, while the effective pressure, p ', associates with the contact pressure at the bone-implant interface. The model performed well (R2 = 0.88-1.0) and differentiated between the parallel-walled (p ' = 0) and tapered implants (p ' = 0.12). The model's parameters could individually represent the effects of the four factors. High bone surrogate density, two-step drill protocol, and rough surface increased both F ' and p '. The cutting flute had opposing effects on F ' and p ' (beta 4 = 0.35 and -0.24, respectively); and therefore, had the lowest net effect on IT. The proposed analytical model therefore improves the understanding of the principal contributors to dental implant IT by considering thread and taper mechanics independently.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Insertion Torque (IT) and Implant Stability Quotient (ISQ) Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study
    Mello, Bruno Freitas
    Formiga, Marcio De Carvalho
    Bianchini, Marco Aurelio
    Borges Jr, Ivan
    Coura, Gustavo
    Tumedei, Margherita
    Fuller, Renato
    Petrini, Morena
    Romasco, Tea
    Vaz, Paula
    Piattelli, Adriano
    Di Pietro, Natalia
    APPLIED SCIENCES-BASEL, 2023, 13 (18):
  • [32] Implant micromotion is related to peak insertion torque and bone density
    Trisi, Paolo
    Perfetti, Giorgio
    Baldoni, Edoardo
    Berardi, Davide
    Colagiovanni, Marco
    Scogna, Giuseppe
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (05) : 467 - 471
  • [33] Biomechanical Evaluation of Resistance to Insertion Torque of Different Implant Systems and Insertion Driver Types
    Nary Filho, Hugo
    Calvo Guirado, Jose Luis
    Matsumoto, Mariza Akemi
    Bresaola, Marco Dapievi
    Aur, Roberto
    IMPLANT DENTISTRY, 2015, 24 (02) : 211 - 216
  • [34] Are the Insertion Torque Value and Implant Stability Quotient Correlated, and If So, Can Insertion Torque Values Predict Secondary Implant Stability? A Prospective Parallel Cohort Study
    Cassetta, Michele
    Brandetti, Giulia
    Altieri, Federica
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 135 - 142
  • [35] Effect of Implant Length and Insertion Depth on Primary Stability of Short Dental Implant
    Wu, Hsiang-Chun
    Huang, Heng-Li
    Fuh, Lih Jyh
    Tsai, Ming Tzu
    Hsu, Jui-Ting
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (01) : 62 - 70
  • [36] Insertion torque of dental implants after microvascular fibular grafting
    Maluf, P. S. Z.
    Ching, A. W.
    Angeletti, P.
    Bretos, J. L. G.
    Ferreira, L. M.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2015, 53 (07): : 647 - 649
  • [37] Prediction of insertion torque and stiffness of a dental implant in bovine trabecular bone using explicit micro-finite element analysis
    Ovesy, Marzieh
    Indermaur, Michael
    Zysset, Philippe K.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 98 : 301 - 310
  • [38] MEASUREMENT OF CLINICIANS' ABILITY To HAND TORQUE DENTAL IMPLANT COMPONENTS
    Kanawati, Ali
    Richards, Mark W.
    Becker, Jeffery J.
    Monaco, Natalie E.
    JOURNAL OF ORAL IMPLANTOLOGY, 2009, 35 (04) : 185 - 188
  • [39] Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
    Velez, Jorge
    Pelaez, Jesus
    Lopez-Suarez, Carlos
    Agustin-Panadero, Ruben
    Tobar, Celia
    Suarez, Maria J.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (08) : 1 - 13
  • [40] Histologic and Biomechanical Evaluation of the Effects of Implant Insertion Torque on Peri-Implant Bone Healing
    Consolo, Ugo
    Travaglini, Domenico
    Todisco, Marzio
    Trisi, Paolo
    Galli, Silvia
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (03) : 860 - 865