Analytical model for dental implant insertion torque

被引:7
|
作者
Yang, Baixuan [1 ]
Irastorza-Landa, Ainara [2 ]
Heuberger, Peter [2 ]
Ploeg, Heidi-Lynn [1 ]
机构
[1] Queens Univ Kingston, Dept Mech & Mat Engn, McLaughlin Hall,130 Stuart St, Kingston, ON K7L 3N6, Canada
[2] Nobel Biocare Serv AG, Balz Zimmermann Str 7, CH-8302 Kloten, Switzerland
基金
加拿大自然科学与工程研究理事会;
关键词
Dental implant; Torque; Model; PRIMARY STABILITY; BONE-DENSITY; OSSEOINTEGRATION; MECHANICS;
D O I
10.1016/j.jmbbm.2022.105223
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Maximum insertion torque (IT) for threaded dental implants is a primary clinical measurement to assess implant anchorage, and strongly influences the clinical outcome. Insertion torque is influenced by surgical technique, implant designs, and patient factors such as bone density and quality. In this study, an analytical model was proposed for IT to estimate contributions from the thread and taper separately. The purpose of this study was to test if the analytical model could 1. differentiate the parallel-walled and tapered implant; and, 2. represent four factors: bone surrogate density, drill protocol, implant surface finish and cutting flute. The IT was modeled as the sum of the torques from the thread's inclined plane and interface shear stress from the tapered body integrated over the surface area, respectively, with two main parameters: effective force, F ', F ' and effective pressure, p '. The effective force, relates to the clamping force from the thread, while the effective pressure, p ', associates with the contact pressure at the bone-implant interface. The model performed well (R2 = 0.88-1.0) and differentiated between the parallel-walled (p ' = 0) and tapered implants (p ' = 0.12). The model's parameters could individually represent the effects of the four factors. High bone surrogate density, two-step drill protocol, and rough surface increased both F ' and p '. The cutting flute had opposing effects on F ' and p ' (beta 4 = 0.35 and -0.24, respectively); and therefore, had the lowest net effect on IT. The proposed analytical model therefore improves the understanding of the principal contributors to dental implant IT by considering thread and taper mechanics independently.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Numerical Simulation of Dental Implant Insertion Process
    Jaworski, Nazariy
    Iwaniec, Marek
    2017 XIIITH INTERNATIONAL CONFERENCE ON PERSPECTIVE TECHNOLOGIES AND METHODS IN MEMS DESIGN (MEMSTECH), 2017, : 59 - 61
  • [22] Relevant Aspects of the Dental Implant Design on the Insertion Torque, Resonance Frequency Analysis (RFA) and Micromobility: An In Vitro Study
    Herrero-Climent, Mariano
    Falcao, Artur
    Tondela, Joao
    Brizuela, Aritza
    Rios-Carrasco, Blanca
    Gil, Javier
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (03)
  • [23] An analytical model to measure dental implant stability with the Advanced System for Implant Stability Testing (ASIST)
    Jar, Chester
    Archibald, Andrew
    Gibson, Monica
    Westover, Lindsey
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 150
  • [24] The effect of implant geometry upon insertion torque: an investigation of three implant designs
    O'Sullivan, D
    Meredith, N
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1063 - 1063
  • [25] Development of a peak insertion torque prediction model for parallel-walled dental implants
    Alsheghri, Ammar A.
    Abdalla, Ali N.
    Mokahhal, Basel
    Cortes, Arthur R. G.
    Garcia-Denche, Jesus Torres
    Celemin, Alicia
    Cascos, Rocio
    Song, Jun
    Tamimi, Faleh
    MEDICAL ENGINEERING & PHYSICS, 2025, 138
  • [26] Effect of Drilling Speed on Dental Implants Insertion Torque
    Varghai, Kaveh
    Eppell, Steven J.
    Wang, Russell
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (05) : 467 - 474
  • [27] Modelling dental implant extraction by pullout and torque procedures
    Rittel, D.
    Dorogoy, A.
    Shemtov-Yona, K.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 71 : 416 - 427
  • [28] Low Insertional Torque and Early Dental Implant Failure
    Carr, Brian R.
    Jeon-Slaughter, Haekyung
    Neal, Timothy W.
    Gulko, Joseph A.
    Kolar, Nicholas C.
    Finn, Richard A.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2022, 80 (06) : 1069 - 1077
  • [29] Implant insertion torque value in immediate loading: A retrospective study
    Del Giudice, Roberto
    Piattelli, Adriano
    Grande, Nicola-Maria
    Cataneo, Enrico
    Crispino, Antonio
    Petrini, Morena
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2019, 24 (03): : E398 - E403
  • [30] Insertion torque/time integral as a measure of primary implant stability
    Grobecker-Karl, Tanja
    Karl, Matthias
    Steiner, Constanze
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2020, 65 (06): : 729 - 733