Positive Contrast MRI Techniques for Visualization of Iron-Loaded Hernia Mesh Implants in Patients

被引:4
|
作者
Ciritsis, Alexander [1 ]
Truhn, Daniel [1 ]
Hansen, Nienke L. [1 ]
Otto, Jens [2 ]
Kuhl, Christiane K. [1 ]
Kraemer, Nils A. [1 ]
机构
[1] RWTH Univ Hosp Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[2] RWTH Univ Hosp Aachen, Dept Gen Visceral & Transplant Surg, Aachen, Germany
来源
PLOS ONE | 2016年 / 11卷 / 05期
关键词
SUSCEPTIBILITY; CELLS; 1ST;
D O I
10.1371/journal.pone.0155717
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Object In MRI, implants and devices can be delineated via susceptibility artefacts. To discriminate susceptibility voids from proton-free structures, different positive contrast techniques were implemented. The purpose of this study was to evaluate a pulse sequence-based positive contrast technique (PCSI) and a post-processing susceptibility gradient mapping algorithm (SGM) for visualization of iron loaded mesh implants in patients. Material and Methods Five patients with iron-loaded MR-visible inguinal hernia mesh implants were examined at 1.5 Tesla. A gradient echo sequence (GRE; parameters: TR: 8.3ms; TE: 4.3ms; NSA: 2; FA: 20 degrees; FOV: 350mm(2)) and a PCSI sequence (parameters: TR: 25ms; TE: 4.6ms; NSA: 4; FA: 20 degrees; FOV: 350mm(2)) with on-resonant proton suppression were performed. SGM maps were calculated using two algorithms. Image quality and mesh delineation were independently evaluated by three radiologists. Results On GRE, the iron-loaded meshes generated distinct susceptibility-induced signal voids. PCSI exhibited susceptibility differences including the meshes as hyperintense signals. SGM exhibited susceptibility differences with positive contrast. Visually, the different algorithms presented no significant differences. Overall, the diagnostic value was rated best in GRE whereas PCSI and SGM were barely "sufficient". Conclusion Both "positive contrast" techniques depicted implanted meshes with hyperintense signal. SGM comes without additional acquisition time and can therefore be utilized in every patient.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] MRI Positive Contrast Visualization of Prostate Brachytherapy Seeds Using An Integrated Laplacian-Based Phase Processing
    Soliman, A.
    Nosrati, R.
    Safigholi, H.
    Owrangi, A.
    Morton, G.
    Song, W.
    MEDICAL PHYSICS, 2016, 43 (06) : 3391 - 3391
  • [42] AUTOMATIC SEGMENTATION AND 3D VISUALIZATION OF PELVIC MESH USING MATHEMATICAL MODELLING AND MACHINE LEARNING TECHNIQUES IN MRI
    Ambartsoumian, Gaik
    Roy, Souvik
    Khatri, Gaurav
    Zimmern, Philippe E.
    JOURNAL OF UROLOGY, 2020, 203 : E605 - E605
  • [43] Automatic segmentation and 3d visualization of pelvic mesh using mathematical modelling and machine learning techniques in mri
    Ambartsoumian, Gaik
    Roy, Souvik
    Khatri, Gaurav
    Zimmern, Philippe E.
    NEUROUROLOGY AND URODYNAMICS, 2020, 39 : S276 - S277
  • [44] AUTOMATIC SEGMENTATION AND 3D VISUALIZATION OF PELVIC MESH USING MATHEMATICAL MODELLING AND MACHINE LEARNING TECHNIQUES IN MRI
    Ambartsoumian, G.
    Roy, S.
    Khatri, G.
    Zimmern, P.
    NEUROUROLOGY AND URODYNAMICS, 2019, 38 : S54 - S55
  • [45] Visualization of discrete microinfarction in patients with unstable angina using delayed contrast-enhanced MRI
    Wang, Y
    Du, XK
    Cao, G
    RADIOLOGY, 2002, 225 : 296 - 296
  • [46] Utilization of SEMAC-VAT MRI for Improved Visualization of Posterior Fossa Structures in Patients With Cochlear Implants
    Amin, Nikul
    Pai, Irumee
    Touska, Philip
    Connor, Steve E. J.
    OTOLOGY & NEUROTOLOGY, 2021, 42 (04) : E451 - E458
  • [47] Predictable heating and positive MRI contrast from a mesoporous silica-coated iron oxide nanoparticle
    Haynes, Christy
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [48] Predictable Heating and Positive MRI Contrast from a Mesoporous Silica-Coated Iron Oxide Nanoparticle
    Hurley, Katie R.
    Ring, Hattie L.
    Etheridge, Michael
    Zhang, Jinjin
    Gao, Zhe
    Shao, Qi
    Klein, Nathan D.
    Szlag, Victoria M.
    Chung, Connie
    Reineke, Theresa M.
    Garwood, Michael
    Bischof, John C.
    Haynes, Christy L.
    MOLECULAR PHARMACEUTICS, 2016, 13 (07) : 2172 - 2183
  • [49] Radiotherapy Guided by Ultrasmall Superparamagnetic Iron Oxide Contrast MRI Staging for Patients with High Risk, Clinically Node Positive or Recurrent Prostate Cancer
    Li, Yun Rose
    Roach, Mack, III
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 103 (05): : E14 - E14
  • [50] Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-Resonant water suppression (IRON)
    Stuber, Matthias
    Gilson, Wesley D.
    Schaer, Michael
    Kedziorek, Dorota A.
    Hofmann, Lawrence V.
    Shah, Saurabh
    Vonken, Evert-Jan
    Bulte, Jeff W. M.
    Kraitchman, Dara L.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) : 1072 - 1077