Positive Contrast MRI Techniques for Visualization of Iron-Loaded Hernia Mesh Implants in Patients

被引:4
|
作者
Ciritsis, Alexander [1 ]
Truhn, Daniel [1 ]
Hansen, Nienke L. [1 ]
Otto, Jens [2 ]
Kuhl, Christiane K. [1 ]
Kraemer, Nils A. [1 ]
机构
[1] RWTH Univ Hosp Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[2] RWTH Univ Hosp Aachen, Dept Gen Visceral & Transplant Surg, Aachen, Germany
来源
PLOS ONE | 2016年 / 11卷 / 05期
关键词
SUSCEPTIBILITY; CELLS; 1ST;
D O I
10.1371/journal.pone.0155717
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Object In MRI, implants and devices can be delineated via susceptibility artefacts. To discriminate susceptibility voids from proton-free structures, different positive contrast techniques were implemented. The purpose of this study was to evaluate a pulse sequence-based positive contrast technique (PCSI) and a post-processing susceptibility gradient mapping algorithm (SGM) for visualization of iron loaded mesh implants in patients. Material and Methods Five patients with iron-loaded MR-visible inguinal hernia mesh implants were examined at 1.5 Tesla. A gradient echo sequence (GRE; parameters: TR: 8.3ms; TE: 4.3ms; NSA: 2; FA: 20 degrees; FOV: 350mm(2)) and a PCSI sequence (parameters: TR: 25ms; TE: 4.6ms; NSA: 4; FA: 20 degrees; FOV: 350mm(2)) with on-resonant proton suppression were performed. SGM maps were calculated using two algorithms. Image quality and mesh delineation were independently evaluated by three radiologists. Results On GRE, the iron-loaded meshes generated distinct susceptibility-induced signal voids. PCSI exhibited susceptibility differences including the meshes as hyperintense signals. SGM exhibited susceptibility differences with positive contrast. Visually, the different algorithms presented no significant differences. Overall, the diagnostic value was rated best in GRE whereas PCSI and SGM were barely "sufficient". Conclusion Both "positive contrast" techniques depicted implanted meshes with hyperintense signal. SGM comes without additional acquisition time and can therefore be utilized in every patient.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] New MRI contrast agents based on silicon nanotubes loaded with superparamagnetic iron oxide nanoparticles
    Gonzalez-Rodriguez, Roberto
    Granitzer, Petra
    Rumpf, Klemens
    Coffer, Jeffery L.
    ROYAL SOCIETY OPEN SCIENCE, 2018, 5 (08):
  • [32] Efficacy and safety of iron-chelation therapy with deferoxamine, deferiprone, and deferasirox for the treatment of iron-loaded patients with nontransfusion-dependent thalassemia syndromes
    Taher, Ali T.
    Porter, John B.
    Kattamis, Antonis
    Viprakasit, Vip
    Cappellini, M. Domenica
    DRUG DESIGN DEVELOPMENT AND THERAPY, 2016, 10 : 7073 - 7075
  • [33] ORAL IRON CHELATION WITH 1,2-DIMETHYL-3-HYDROXYPYRID-4-ONE (L1) IN IRON-LOADED THALASSEMIA PATIENTS
    OLIVIERI, NF
    MATSUI, D
    LIU, PP
    BLENDIS, L
    CAMERON, R
    MCCLELLAND, RA
    TEMPLETON, DM
    KOREN, G
    BONE MARROW TRANSPLANTATION, 1993, 12 : 9 - 11
  • [34] CARS microscopy for the visualization of micrometer-sized iron oxide MRI contrast agents in living cells
    Rago, Gianluca
    Langer, Carolin M.
    Brackman, Christian
    Day, James P. R.
    Domke, Katrin F.
    Raschzok, Nathanael
    Schmidt, Christian
    Sauer, Igor M.
    Enejder, Annika
    Mogl, Martina T.
    Bonn, Mischa
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (09): : 2470 - 2483
  • [35] EVALUATION OF THE ORAL IRON CHELATOR 1,2-DIMETHYL-3-HYDROXYPRID-4-ONE (L1) IN IRON-LOADED PATIENTS
    OLIVIERI, NF
    TEMPLETON, DM
    KOREN, G
    CHUNG, D
    HERMANN, C
    FREEDMAN, MH
    MCCLELLAND, RA
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1990, 612 : 369 - 377
  • [36] Liposomes Loaded with Hydrophobic Iron Oxide Nanoparticles: Suitable T2 Contrast Agents for MRI
    Martinez-Gonzalez, Raquel
    Estelrich, Joan
    Antonia Busquets, Maria
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2016, 17 (08):
  • [37] Peripheral blood immunoprofiling in patients with polypropylene mesh implants for hernia repair: a single-center cohort study
    Jisova, Barbora
    Ebel, Matyas
    de Beaux, Andrew
    East, Barbora
    HERNIA, 2025, 29 (01)
  • [38] Evaluation of cardiac status in iron-loaded thalassaemia patients following bone marrow transplantation: improvement in cardiac function during reduction in body iron burden
    Mariotti, E
    Angelucci, E
    Agostini, A
    Baronciani, D
    Sgarbi, E
    Lucarelli, G
    BRITISH JOURNAL OF HAEMATOLOGY, 1998, 103 (04) : 916 - 921
  • [39] Efficacy and safety of iron-chelation therapy with deferoxamine, deferiprone, and deferasirox for the treatment of iron-loaded patients with non-transfusion-dependent thalassemia syndromes
    Kontoghiorghe, Christina N.
    Kontoghiorghes, George J.
    DRUG DESIGN DEVELOPMENT AND THERAPY, 2016, 10 : 465 - 481
  • [40] Efficacy and safety of iron-chelation therapy with deferoxamine, deferiprone, and deferasirox for the treatment of iron-loaded patients with nontransfusion-dependent thalassemia syndromes Reply
    Kontoghiorghes, George J.