Positive Contrast MRI Techniques for Visualization of Iron-Loaded Hernia Mesh Implants in Patients

被引:4
|
作者
Ciritsis, Alexander [1 ]
Truhn, Daniel [1 ]
Hansen, Nienke L. [1 ]
Otto, Jens [2 ]
Kuhl, Christiane K. [1 ]
Kraemer, Nils A. [1 ]
机构
[1] RWTH Univ Hosp Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[2] RWTH Univ Hosp Aachen, Dept Gen Visceral & Transplant Surg, Aachen, Germany
来源
PLOS ONE | 2016年 / 11卷 / 05期
关键词
SUSCEPTIBILITY; CELLS; 1ST;
D O I
10.1371/journal.pone.0155717
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Object In MRI, implants and devices can be delineated via susceptibility artefacts. To discriminate susceptibility voids from proton-free structures, different positive contrast techniques were implemented. The purpose of this study was to evaluate a pulse sequence-based positive contrast technique (PCSI) and a post-processing susceptibility gradient mapping algorithm (SGM) for visualization of iron loaded mesh implants in patients. Material and Methods Five patients with iron-loaded MR-visible inguinal hernia mesh implants were examined at 1.5 Tesla. A gradient echo sequence (GRE; parameters: TR: 8.3ms; TE: 4.3ms; NSA: 2; FA: 20 degrees; FOV: 350mm(2)) and a PCSI sequence (parameters: TR: 25ms; TE: 4.6ms; NSA: 4; FA: 20 degrees; FOV: 350mm(2)) with on-resonant proton suppression were performed. SGM maps were calculated using two algorithms. Image quality and mesh delineation were independently evaluated by three radiologists. Results On GRE, the iron-loaded meshes generated distinct susceptibility-induced signal voids. PCSI exhibited susceptibility differences including the meshes as hyperintense signals. SGM exhibited susceptibility differences with positive contrast. Visually, the different algorithms presented no significant differences. Overall, the diagnostic value was rated best in GRE whereas PCSI and SGM were barely "sufficient". Conclusion Both "positive contrast" techniques depicted implanted meshes with hyperintense signal. SGM comes without additional acquisition time and can therefore be utilized in every patient.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Efficacy of positive contrast imaging techniques for molecular MRI of tumor angiogenesis
    Wolters, M.
    Oostendorp, M.
    Coolen, B. F.
    Post, M. J.
    Janssen, J. M. H.
    Strijkers, G. J.
    Kooi, M. E.
    Nicolay, K.
    Backes, W. H.
    CONTRAST MEDIA & MOLECULAR IMAGING, 2012, 7 (02) : 130 - 139
  • [22] Long-term complications of bone marrow transplantation (BMT) in iron-loaded patients.
    Anderson, R
    Basran, R
    Blanchette, N
    Klein, N
    Muroff, A
    Amylon, M
    Brittenham, GM
    Mentzer, W
    Vichinsky, EP
    Olivieri, NF
    BLOOD, 1996, 88 (10) : 1037 - 1037
  • [23] Exceedingly small iron oxide nanoparticles as positive MRI contrast agents
    Wei, He
    Bruns, Oliver T.
    Kaul, Michael G.
    Hansen, Eric C.
    Barch, Mariya
    Wisniowska, Agata
    Chen, Ou
    Chen, Yue
    Li, Nan
    Okada, Satoshi
    Cordero, Jose M.
    Heine, Markus
    Farrar, Christian T.
    Montana, Daniel M.
    Adam, Gerhard
    Ittrich, Harald
    Jasanoff, Alan
    Nielsen, Peter
    Bawendi, Moungi G.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2017, 114 (09) : 2325 - 2330
  • [24] Study of deferiprone or deferoxamine versus combination therapy in iron-loaded thalassemia patients in Taiwan.
    Peng, Ching-Tien
    Wu, Kang-Hsi
    Tsai, Chang-Hai
    Yang, Chao-Ping
    Wang, Lin-Yen
    Jang, Ren-Chin
    Hsiao, Chih-Cheng
    BLOOD, 2006, 108 (11) : 7B - 7B
  • [25] Early Postsurgical Visualization of Composite Mesh Used in Ventral Hernia Repair by Amide Proton Transfer MRI
    Franconi, Florence
    Roux, Jerome
    Garric, Xavier
    Lemaire, Laurent
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 313 - 317
  • [26] Positive contrast technique for the detection and quantification of superparamagnetic iron oxide nanoparticles in MRI
    Zhao, Qun
    Langley, Jason
    Lee, Sunbok
    Liu, Wei
    NMR IN BIOMEDICINE, 2011, 24 (05) : 464 - 472
  • [27] PROPHYLACTIC MESH FOR PREVENTION OF INCISIONAL HERNIA IN HIGH-RISK PATIENTS: PVDF "VISIBLE" MESH BEHAVIOUR ON MRI
    Carrasco Aguilera, Beatriz
    Silva Torres, Marinada
    Rodicio, Jose
    Fernandez del Valle, Ana
    Moreno, Maria
    Amoza, Sonia
    Del Val Ruiz, Pablo
    Martinez-Cachero Garcia, Miguel
    Sanz Alvarez, Lourdes
    Menendez, Rafael
    Garcia Urena, Miguel Angel
    BRITISH JOURNAL OF SURGERY, 2021, 108
  • [28] Prospective cohort study on mesh shrinkage measured with MRI after robot-assisted minimal invasive retrorectus ventral hernia repair using an iron-oxide-loaded polyvinylidene fluoride mesh
    Vierstraete, Maaike
    Beckers, Roel
    Vangeel, Lorenz
    Foriers, Brend
    Pletinckx, Pieter
    Muysoms, Filip
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2023, 37 (06): : 4604 - 4612
  • [29] P-076 PROSPECTIVE COHORT STUDY ON MESH SHRINKAGE MEASURED WITH MRI AFTER ROBOT ASSISTED MINIMAL INVASIVE RETRORECTUS VENTRAL HERNIA REPAIR USING AN IRON OXIDE LOADED PVDF MESH
    Vierstraete, M.
    Beckers, R.
    Vangeel, L.
    Foriers, B.
    Pletinckx, P.
    Muysoms, F.
    BRITISH JOURNAL OF SURGERY, 2022, 109
  • [30] Prospective cohort study on mesh shrinkage measured with MRI after robot-assisted minimal invasive retrorectus ventral hernia repair using an iron-oxide-loaded polyvinylidene fluoride mesh
    Maaike Vierstraete
    Roel Beckers
    Lorenz Vangeel
    Brend Foriers
    Pieter Pletinckx
    Filip Muysoms
    Surgical Endoscopy, 2023, 37 : 4604 - 4612