Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-Resonant water suppression (IRON)

被引:178
|
作者
Stuber, Matthias
Gilson, Wesley D.
Schaer, Michael
Kedziorek, Dorota A.
Hofmann, Lawrence V.
Shah, Saurabh
Vonken, Evert-Jan
Bulte, Jeff W. M.
Kraitchman, Dara L.
机构
[1] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Dept Elect & Comp Engn, Sch Med, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Dept Med, Sch Med, Div Cardiol, Baltimore, MD USA
[4] Philips Med Syst, Cleveland, OH USA
[5] Johns Hopkins Univ, Sch Med, Inst Ceell Engn, Baltimore, MD USA
[6] Stanford Univ, Sch Med, Stanford, CA 94305 USA
[7] Johns Hopkins Univ, Sch Med, Dept Chem & Biomol Engn, Baltimore, MD USA
关键词
positive contrast imaging; off-resonance imaging; SPIO-labeled stem cells; metallic objects; white-marker objects;
D O I
10.1002/mrm.21399
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ability to illuminate these structures with positive contrast would enhance noninvasive MR tracking of cellular therapeutics. Therefore, an MRI methodology that selectively highlights areas of metallic objects has been developed. Inversion-recovery with ON-resonant water suppression (IRON) employs inversion of the magnetization in conjunction with a spectrally-selective on-resonant saturation prepulse. If imaging is performed after these prepulses, positive signal is obtained from off-resonant protons in close proximity to the metallic objects. The first successful use of IRON to produce positive contrast in areas of metallic spheres and SPIO-labeled stem cells in vitro and in vivo is presented.
引用
收藏
页码:1072 / 1077
页数:6
相关论文
共 42 条
  • [1] Positive contrast MR-lymphography using inversion recovery with ON-resonant water suppression (IRON)
    Korosogiou, Grigorios
    Tang, Lijun
    Kedziorek, Dorota
    Cosby, Kenyatta
    Gilson, Wesley D.
    Vonken, Evert-Jan
    Schaer, Michael
    Sosnovik, David
    Kraitchman, Dara L.
    Weiss, Robert G.
    Weissleder, Ralf
    Stuber, Matthias
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (05) : 1175 - 1180
  • [2] 2131 The dual contrast mechanism in inversion recovery with on-resonant water suppression magnetic resonance angiography (IRON-MRA) after administration of iron oxide nanoparticles
    Evert-jan Vonken
    Grigorios Korosoglou
    Jing Yu
    Michael Schär
    Ralph Weissleder
    Matthias Stuber
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [3] Positive contrast inversion-recovery with oxide nanoparticles-resonant water suppression magnetic resonance imaging - A change for the better?
    Lipinski, Michael J.
    Briley-Saebo, Karen C.
    Mani, Venkatesh
    Fayad, Zahi A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (06) : 492 - 494
  • [4] Positive-Contrast Visualization of Iron-Oxide-Labeled Cells
    Jakob, Peter M.
    Haddad, Daniel
    EMAGRES, 2012, 1 (04): : 837 - 847
  • [5] Transferrin receptor expression in iron oxide-labeled mesenchymal stem cells
    Pawelczyk, Edyta
    Frank, Joseph A.
    RADIOLOGY, 2008, 247 (03)
  • [6] In vivo MRI mapping of iron oxide-labeled stem cells transplanted in the heart
    Ruggiero, A.
    Guenoun, J.
    Smit, H.
    Doeswijk, G. N.
    Klein, S.
    Krestin, G. P.
    Kotek, G.
    Bernsen, M. R.
    CONTRAST MEDIA & MOLECULAR IMAGING, 2013, 8 (06) : 487 - 494
  • [7] Specific identification of iron oxide-labeled stem cells using magnetic field hyperthermia and MR thermometry
    Haddad, Daniel
    Hildenbrand, Markus F.
    Hiller, Karl-Heinz
    Haddad-Weber, Meike
    Jakob, Peter M.
    NMR IN BIOMEDICINE, 2012, 25 (03) : 402 - 409
  • [8] Positive Contrast inversion-recovery with oxide nanoparticles-resonant water suppression magnetic resonance imaging: A change for the better? (vol 52, pg 492, 2008)
    Lipinski, M. J.
    Briley-Saebo, K. C.
    Mani, V
    Fayad, Z. A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (12) : 1040 - 1040
  • [9] Serial in vivo positive contrast MRI of iron oxide-labeled embiryonic stem cell-derived cardiac precursor cells in a mouse model of myocardial infarction
    Mani, Venkatesh
    Adler, Eric
    Briley-Saebo, Karen C.
    Bystrup, Anne
    Fuster, Valentin
    Keller, Gordon
    Fayad, Zahi A.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) : 73 - 81
  • [10] The application of super paramagnetic iron oxide-labeled mesenchymal stem cells in cell-based therapy
    Qi, Yiying
    Feng, Gang
    Huang, Zhongming
    Yan, Weiqi
    MOLECULAR BIOLOGY REPORTS, 2013, 40 (03) : 2733 - 2740