Positive Contrast MRI Techniques for Visualization of Iron-Loaded Hernia Mesh Implants in Patients

被引:4
|
作者
Ciritsis, Alexander [1 ]
Truhn, Daniel [1 ]
Hansen, Nienke L. [1 ]
Otto, Jens [2 ]
Kuhl, Christiane K. [1 ]
Kraemer, Nils A. [1 ]
机构
[1] RWTH Univ Hosp Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[2] RWTH Univ Hosp Aachen, Dept Gen Visceral & Transplant Surg, Aachen, Germany
来源
PLOS ONE | 2016年 / 11卷 / 05期
关键词
SUSCEPTIBILITY; CELLS; 1ST;
D O I
10.1371/journal.pone.0155717
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Object In MRI, implants and devices can be delineated via susceptibility artefacts. To discriminate susceptibility voids from proton-free structures, different positive contrast techniques were implemented. The purpose of this study was to evaluate a pulse sequence-based positive contrast technique (PCSI) and a post-processing susceptibility gradient mapping algorithm (SGM) for visualization of iron loaded mesh implants in patients. Material and Methods Five patients with iron-loaded MR-visible inguinal hernia mesh implants were examined at 1.5 Tesla. A gradient echo sequence (GRE; parameters: TR: 8.3ms; TE: 4.3ms; NSA: 2; FA: 20 degrees; FOV: 350mm(2)) and a PCSI sequence (parameters: TR: 25ms; TE: 4.6ms; NSA: 4; FA: 20 degrees; FOV: 350mm(2)) with on-resonant proton suppression were performed. SGM maps were calculated using two algorithms. Image quality and mesh delineation were independently evaluated by three radiologists. Results On GRE, the iron-loaded meshes generated distinct susceptibility-induced signal voids. PCSI exhibited susceptibility differences including the meshes as hyperintense signals. SGM exhibited susceptibility differences with positive contrast. Visually, the different algorithms presented no significant differences. Overall, the diagnostic value was rated best in GRE whereas PCSI and SGM were barely "sufficient". Conclusion Both "positive contrast" techniques depicted implanted meshes with hyperintense signal. SGM comes without additional acquisition time and can therefore be utilized in every patient.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Positive Contrast MRI Techniques for Visualization of Iron-Loaded Hernia Mesh Implants in Patients (vol 11, e0155717, 2016)
    Ciritsis, Alexander
    Truhn, Daniel
    Hansen, Nienke L.
    Otto, Jens
    Kuhl, Christiane K.
    Kraemer, Nils A.
    PLOS ONE, 2016, 11 (09):
  • [2] Magnetic resonance visualization of iron-loaded meshes in patients with pain after inguinal hernia repair
    E. Özveri
    D. E. T. Şanlı
    D. Yıldırım
    H. Gök
    M. Ertem
    Hernia, 2021, 25 : 727 - 732
  • [3] Magnetic resonance visualization of iron-loaded meshes in patients with pain after inguinal hernia repair
    Ozveri, E.
    Sanli, D. E. T.
    Yildirim, D.
    Gok, H.
    Ertem, M.
    HERNIA, 2021, 25 (03) : 727 - 732
  • [4] In vivo MRI visualization of mesh shrinkage using surgical implants loaded with superparamagnetic iron oxides
    Kuehnert, Nicolas
    Kraemer, Nils A.
    Otto, Jens
    Donker, Hank C. W.
    Slabu, Ioana
    Baumann, Martin
    Kuhl, Christiane K.
    Klinge, Uwe
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (05): : 1468 - 1475
  • [5] In vivo MRI visualization of mesh shrinkage using surgical implants loaded with superparamagnetic iron oxides
    Nicolas Kuehnert
    Nils A. Kraemer
    Jens Otto
    Hank C. W. Donker
    Ioana Slabu
    Martin Baumann
    Christiane K. Kuhl
    Uwe Klinge
    Surgical Endoscopy, 2012, 26 : 1468 - 1475
  • [6] Detection limits of SPIO loaded mesh implants for visualization in MRI and MPI
    Ariens, M.
    Wiekhorst, F.
    Schmitz-Rode, T.
    Baumann, M.
    Kuhl, C.
    Liess, C.
    Trahms, L.
    Slabu, I
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S635 - S635
  • [7] Optimization of iron-loaded nanoparticles for T1-weighted MRI contrast enhancement
    Ditri, Treffly
    Li, Yiwen
    Wang, Zhao
    Huang, Yuran
    Xie, Yijun
    Botta, Mauro
    Rinehart, Jeffrey
    Gianneschi, Nathan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [8] Iron-loaded PLLA nanoparticles as highly efficient intracellular markers for visualization of mesenchymal stromal cells by MRI
    Vernikouskaya, I.
    Fekete, N.
    Bannwarth, M.
    Erle, A.
    Rojewski, M.
    Landfester, K.
    Schmidtke-Schrezenmeier, G.
    Schrezenmeier, H.
    Rasche, V.
    CONTRAST MEDIA & MOLECULAR IMAGING, 2014, 9 (02) : 109 - 121
  • [9] Iron-Loaded Magnetic Nanocapsules for pH-Triggered Drug Release and MRI Imaging
    Chen, Hongyu
    Sulejmanovic, Dino
    Moore, Thomas
    Colvin, Daniel C.
    Qi, Bin
    Mefford, O. Thompson
    Gore, John C.
    Alexis, Frank
    Hwu, Shiou-Jyh
    Anker, Jeffrey N.
    CHEMISTRY OF MATERIALS, 2014, 26 (06) : 2105 - 2112
  • [10] Improved MRI R2* Relaxometry of Iron-Loaded Liver with Noise Correction
    Feng, Yanqiu
    He, Taigang
    Gatehouse, Peter D.
    Li, Xinzhong
    Harith Alam, Mohammed
    Pennell, Dudley J.
    Chen, Wufan
    Firmin, David N.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1765 - 1774