In vivo MRI visualization of mesh shrinkage using surgical implants loaded with superparamagnetic iron oxides

被引:44
|
作者
Kuehnert, Nicolas [1 ]
Kraemer, Nils A. [2 ]
Otto, Jens [1 ]
Donker, Hank C. W. [2 ]
Slabu, Ioana [3 ]
Baumann, Martin [3 ]
Kuhl, Christiane K. [2 ]
Klinge, Uwe [1 ,3 ]
机构
[1] Rhein Westfal TH Aachen, Dept Surg, Univ Hosp, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Dept Diagnost Radiol, Univ Hosp, D-52074 Aachen, Germany
[3] Rhein Westfal TH Aachen, Helmholtz Inst Appl Med Engn, D-52074 Aachen, Germany
关键词
Magnetic resonance imaging; SPIO; Mesh implant; Shrinkage; INCISIONAL HERNIA REPAIR; FUNCTIONAL CINE MRI; ADHESION FORMATION; COMPLICATION RATES; SYNTHETIC MESH; ULTRASONOGRAPHY; POLYPROPYLENE; EXCISION;
D O I
10.1007/s00464-011-2057-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
Prosthetic mesh implants are widely used in hernia surgery. To show long-term mesh-related complications such as shrinkage or adhesions, a precise visualization of meshes and their vicinity in vivo is important. By supplementing mesh fibers with ferro particles, magnetic resonance imaging (MRI) can help to delineate the mesh itself. This study aimed to demonstrate and quantify time-dependent mesh shrinkage in vivo by MRI. Polyvinylidenfluoride (PVDF) meshes with incorporated superparamagnetic iron oxides (SPIOs) were implanted as an abdominal wall replacement in 30 rats. On days 1, 7, 14, or 21, MRI was performed using a gradient echo sequence with repetition time (TR)/echo time (TE) of 50/4.6 and a flip angle of 20A degrees. The length, width, and area of the device were measured on axial, coronal, and sagittal images, and geometric deformations were assessed by surgical explantation. In all cases, the meshes were visualized and their area estimated by measuring the length and width of the mesh. The MRI presented a mean area shrinkage in vivo of 13% on day 7, 23% on day 14, and 23% on day 21. Postmortem measurements differed statistically from MRI, with a mean area shrinkage of 23% on day 7, 28% on day 14, and 30% on day 21. Ex vivo measurements of shrinkage showed in vivo measurements to be overestimated approximately 8%. Delineation of the mesh helped to show folding or adhesions close to the intestine. Loading of surgical meshes with SPIOs allows their precise visualization during MRI and guarantees an accurate in vivo assessment of their shrinkage. The authors' observation clearly indicates that shrinkage in vivo is remarkably less than that shown by illustrated explantation measurements. The use of MRI with such meshes could be a reliable technique for checking on proper operation of implanted meshes and showing related complications, obviating the need for exploratory open surgical revision.
引用
收藏
页码:1468 / 1475
页数:8
相关论文
共 50 条
  • [1] In vivo MRI visualization of mesh shrinkage using surgical implants loaded with superparamagnetic iron oxides
    Nicolas Kuehnert
    Nils A. Kraemer
    Jens Otto
    Hank C. W. Donker
    Ioana Slabu
    Martin Baumann
    Christiane K. Kuhl
    Uwe Klinge
    Surgical Endoscopy, 2012, 26 : 1468 - 1475
  • [2] SUPERPARAMAGNETIC IRON OXIDES FOR MR-VISUALIZATION OF TEXTILE IMPLANTS
    Slabu, I.
    Schmitz-Rode, T.
    Hodenius, M.
    Klinge, U.
    Otto, J.
    Krombach, G. A.
    Kraemer, N.
    Donker, H.
    Baumann, M.
    MAGNETIC NANOPARTICLES: PARTICLE SCIENCE, IMAGING TECHNOLOGY, AND CLINICAL APPLICATIONS, 2010, : 217 - 223
  • [3] Positive Contrast MRI Techniques for Visualization of Iron-Loaded Hernia Mesh Implants in Patients
    Ciritsis, Alexander
    Truhn, Daniel
    Hansen, Nienke L.
    Otto, Jens
    Kuhl, Christiane K.
    Kraemer, Nils A.
    PLOS ONE, 2016, 11 (05):
  • [4] Detection limits of SPIO loaded mesh implants for visualization in MRI and MPI
    Ariens, M.
    Wiekhorst, F.
    Schmitz-Rode, T.
    Baumann, M.
    Kuhl, C.
    Liess, C.
    Trahms, L.
    Slabu, I
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S635 - S635
  • [5] Investigation of Superparamagnetic Iron Oxide Nanoparticles for MR-Visualization of Surgical Implants
    Slabu, I.
    Guentherodt, G.
    Schmitz-Rode, T.
    Hodenius, M.
    Kraemer, N.
    Donker, H.
    Krombach, G. A.
    Otto, J.
    Klinge, U.
    Baumann, M.
    CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2012, 13 (04) : 545 - 551
  • [6] In vivo fate of superparamagnetic iron oxides during sepsis
    Fujii, H
    Yoshikawa, K
    Berliner, LJ
    MAGNETIC RESONANCE IMAGING, 2002, 20 (03) : 271 - 276
  • [7] In vivo visualization of cells labeled with superparamagnetic iron oxides by a sub-millisecond gradient echo sequence
    Xeni Deligianni
    Daniel Jirák
    Zuzana Berková
    Milan Hájek
    Klaus Scheffler
    Oliver Bieri
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 329 - 337
  • [8] In vivo visualization of cells labeled with superparamagnetic iron oxides by a sub-millisecond gradient echo sequence
    Deligianni, Xeni
    Jirak, Daniel
    Berkova, Zuzana
    Hajek, Milan
    Scheffler, Klaus
    Bieri, Oliver
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (04) : 329 - 337
  • [9] Positive Contrast MRI Techniques for Visualization of Iron-Loaded Hernia Mesh Implants in Patients (vol 11, e0155717, 2016)
    Ciritsis, Alexander
    Truhn, Daniel
    Hansen, Nienke L.
    Otto, Jens
    Kuhl, Christiane K.
    Kraemer, Nils A.
    PLOS ONE, 2016, 11 (09):
  • [10] In vivo MRI visualization of parastomal mesh in a porcine model
    J. Otto
    D. Busch
    C. Klink
    A. Ciritsis
    A. Woitok
    C. Kuhl
    U. Klinge
    U. P. Neumann
    N. A. Kraemer
    J. Conze
    Hernia, 2014, 18 : 663 - 670