In vivo MRI visualization of mesh shrinkage using surgical implants loaded with superparamagnetic iron oxides

被引:44
|
作者
Kuehnert, Nicolas [1 ]
Kraemer, Nils A. [2 ]
Otto, Jens [1 ]
Donker, Hank C. W. [2 ]
Slabu, Ioana [3 ]
Baumann, Martin [3 ]
Kuhl, Christiane K. [2 ]
Klinge, Uwe [1 ,3 ]
机构
[1] Rhein Westfal TH Aachen, Dept Surg, Univ Hosp, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Dept Diagnost Radiol, Univ Hosp, D-52074 Aachen, Germany
[3] Rhein Westfal TH Aachen, Helmholtz Inst Appl Med Engn, D-52074 Aachen, Germany
关键词
Magnetic resonance imaging; SPIO; Mesh implant; Shrinkage; INCISIONAL HERNIA REPAIR; FUNCTIONAL CINE MRI; ADHESION FORMATION; COMPLICATION RATES; SYNTHETIC MESH; ULTRASONOGRAPHY; POLYPROPYLENE; EXCISION;
D O I
10.1007/s00464-011-2057-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
Prosthetic mesh implants are widely used in hernia surgery. To show long-term mesh-related complications such as shrinkage or adhesions, a precise visualization of meshes and their vicinity in vivo is important. By supplementing mesh fibers with ferro particles, magnetic resonance imaging (MRI) can help to delineate the mesh itself. This study aimed to demonstrate and quantify time-dependent mesh shrinkage in vivo by MRI. Polyvinylidenfluoride (PVDF) meshes with incorporated superparamagnetic iron oxides (SPIOs) were implanted as an abdominal wall replacement in 30 rats. On days 1, 7, 14, or 21, MRI was performed using a gradient echo sequence with repetition time (TR)/echo time (TE) of 50/4.6 and a flip angle of 20A degrees. The length, width, and area of the device were measured on axial, coronal, and sagittal images, and geometric deformations were assessed by surgical explantation. In all cases, the meshes were visualized and their area estimated by measuring the length and width of the mesh. The MRI presented a mean area shrinkage in vivo of 13% on day 7, 23% on day 14, and 23% on day 21. Postmortem measurements differed statistically from MRI, with a mean area shrinkage of 23% on day 7, 28% on day 14, and 30% on day 21. Ex vivo measurements of shrinkage showed in vivo measurements to be overestimated approximately 8%. Delineation of the mesh helped to show folding or adhesions close to the intestine. Loading of surgical meshes with SPIOs allows their precise visualization during MRI and guarantees an accurate in vivo assessment of their shrinkage. The authors' observation clearly indicates that shrinkage in vivo is remarkably less than that shown by illustrated explantation measurements. The use of MRI with such meshes could be a reliable technique for checking on proper operation of implanted meshes and showing related complications, obviating the need for exploratory open surgical revision.
引用
收藏
页码:1468 / 1475
页数:8
相关论文
共 50 条
  • [21] Prospective cohort study on mesh shrinkage measured with MRI after robot-assisted minimal invasive retrorectus ventral hernia repair using an iron-oxide-loaded polyvinylidene fluoride mesh
    Vierstraete, Maaike
    Beckers, Roel
    Vangeel, Lorenz
    Foriers, Brend
    Pletinckx, Pieter
    Muysoms, Filip
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2023, 37 (06): : 4604 - 4612
  • [22] P-076 PROSPECTIVE COHORT STUDY ON MESH SHRINKAGE MEASURED WITH MRI AFTER ROBOT ASSISTED MINIMAL INVASIVE RETRORECTUS VENTRAL HERNIA REPAIR USING AN IRON OXIDE LOADED PVDF MESH
    Vierstraete, M.
    Beckers, R.
    Vangeel, L.
    Foriers, B.
    Pletinckx, P.
    Muysoms, F.
    BRITISH JOURNAL OF SURGERY, 2022, 109
  • [23] Prospective cohort study on mesh shrinkage measured with MRI after robot-assisted minimal invasive retrorectus ventral hernia repair using an iron-oxide-loaded polyvinylidene fluoride mesh
    Maaike Vierstraete
    Roel Beckers
    Lorenz Vangeel
    Brend Foriers
    Pieter Pletinckx
    Filip Muysoms
    Surgical Endoscopy, 2023, 37 : 4604 - 4612
  • [24] In vivo MRI using positive-contrast techniques in detection of cells labeled with superparamagnetic iron oxide nanoparticles
    Liu, Wei
    Dahnke, Hannes
    Jordan, E. Kay
    Schaeffter, Tobias
    Frank, Joseph A.
    NMR IN BIOMEDICINE, 2008, 21 (03) : 242 - 250
  • [25] New MRI contrast agents based on silicon nanotubes loaded with superparamagnetic iron oxide nanoparticles
    Gonzalez-Rodriguez, Roberto
    Granitzer, Petra
    Rumpf, Klemens
    Coffer, Jeffery L.
    ROYAL SOCIETY OPEN SCIENCE, 2018, 5 (08):
  • [26] Superparamagnetic iron oxide nanoparticles for direct labeling of stem cells and in vivo MRI tracking
    Kim, Saejeong J.
    Lewis, Bobbi
    Steiner, Mark-Steven
    Bissa, Ursula V.
    Dose, Christian
    Frank, Joseph A.
    CONTRAST MEDIA & MOLECULAR IMAGING, 2016, 11 (01) : 55 - 64
  • [27] Drug-loaded superparamagnetic iron oxide nanoparticles for combined cancer imaging and therapy in vivo
    Yu, Mi Kyung
    Jeong, Yong Yeon
    Park, Jinho
    Park, Sangjin
    Kim, Jin Woong
    Min, Jung Jun
    Kim, Kyuwon
    Jon, Sangyong
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2008, 47 (29) : 5362 - 5365
  • [28] CELL TRACKING FOR CARTILAGE REPAIR USING SUPERPARAMAGNETIC IRON OXIDES: CLINICAL POTENTIAL
    van Buul, G. M.
    Kotek, G.
    Wielopolski, P. A.
    Farrell, E.
    Bos, P. K.
    Weinans, H.
    Verhaar, J. A.
    Krestin, G. P.
    Bernsen, M. R.
    van Osch, G. J.
    OSTEOARTHRITIS AND CARTILAGE, 2010, 18 : S80 - S80
  • [29] Superparamagnetic iron oxides and low molecular weight gadolinium chelates are synergistic for direct visualization of advanced liver fibrosis
    Hughes-Cassidy, Fiona
    Chavez, Alyssa D.
    Schlang, Adrienne
    Hassanein, Tarek
    Gamst, Anthony
    Wolfson, Tanya
    Sirlin, Claude
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (03) : 728 - 737
  • [30] Pitfalls in employing superparamagnetic iron oxide particles for stem cell labelling and in vivo MRI tracking
    Wang, Y-X J.
    Wang, H-H
    Au, D. W. T.
    Zou, B-S
    Teng, L-S
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (972): : 987 - 988