In vivo MRI visualization of mesh shrinkage using surgical implants loaded with superparamagnetic iron oxides

被引:44
|
作者
Kuehnert, Nicolas [1 ]
Kraemer, Nils A. [2 ]
Otto, Jens [1 ]
Donker, Hank C. W. [2 ]
Slabu, Ioana [3 ]
Baumann, Martin [3 ]
Kuhl, Christiane K. [2 ]
Klinge, Uwe [1 ,3 ]
机构
[1] Rhein Westfal TH Aachen, Dept Surg, Univ Hosp, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Dept Diagnost Radiol, Univ Hosp, D-52074 Aachen, Germany
[3] Rhein Westfal TH Aachen, Helmholtz Inst Appl Med Engn, D-52074 Aachen, Germany
关键词
Magnetic resonance imaging; SPIO; Mesh implant; Shrinkage; INCISIONAL HERNIA REPAIR; FUNCTIONAL CINE MRI; ADHESION FORMATION; COMPLICATION RATES; SYNTHETIC MESH; ULTRASONOGRAPHY; POLYPROPYLENE; EXCISION;
D O I
10.1007/s00464-011-2057-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
Prosthetic mesh implants are widely used in hernia surgery. To show long-term mesh-related complications such as shrinkage or adhesions, a precise visualization of meshes and their vicinity in vivo is important. By supplementing mesh fibers with ferro particles, magnetic resonance imaging (MRI) can help to delineate the mesh itself. This study aimed to demonstrate and quantify time-dependent mesh shrinkage in vivo by MRI. Polyvinylidenfluoride (PVDF) meshes with incorporated superparamagnetic iron oxides (SPIOs) were implanted as an abdominal wall replacement in 30 rats. On days 1, 7, 14, or 21, MRI was performed using a gradient echo sequence with repetition time (TR)/echo time (TE) of 50/4.6 and a flip angle of 20A degrees. The length, width, and area of the device were measured on axial, coronal, and sagittal images, and geometric deformations were assessed by surgical explantation. In all cases, the meshes were visualized and their area estimated by measuring the length and width of the mesh. The MRI presented a mean area shrinkage in vivo of 13% on day 7, 23% on day 14, and 23% on day 21. Postmortem measurements differed statistically from MRI, with a mean area shrinkage of 23% on day 7, 28% on day 14, and 30% on day 21. Ex vivo measurements of shrinkage showed in vivo measurements to be overestimated approximately 8%. Delineation of the mesh helped to show folding or adhesions close to the intestine. Loading of surgical meshes with SPIOs allows their precise visualization during MRI and guarantees an accurate in vivo assessment of their shrinkage. The authors' observation clearly indicates that shrinkage in vivo is remarkably less than that shown by illustrated explantation measurements. The use of MRI with such meshes could be a reliable technique for checking on proper operation of implanted meshes and showing related complications, obviating the need for exploratory open surgical revision.
引用
收藏
页码:1468 / 1475
页数:8
相关论文
共 50 条
  • [31] Quiz Yourself in Lymph Node Characterization With Lymphotropic Nanoparticle-Enhanced MRI Using Superparamagnetic Iron Oxides! (CME Credit Available)
    Islam, T.
    Braschi, M.
    Oliveira, G.
    Harisinghani, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [32] Design of dye and superparamagnetic iron oxide nanoparticle loaded lipid nanocapsules with dual detectability in vitro and in vivo
    Bohley, Marilena S.
    Birch, Emily
    Baumann, Felix J.
    Dillinger, Andrea E.
    Tamm, Ernst R.
    Goepferich, Achim M.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2020, 585
  • [33] In Vivo Visualization of Polymer-Based Mesh Implants Using Conventional Magnetic Resonance Imaging and Positive-Contrast Susceptibility Imaging
    Kraemer, Nils A.
    Donker, Hank C. W.
    Kuehnert, Nicolas
    Otto, Jens
    Schrading, Simone
    Krombach, Gabriele A.
    Klinge, Uwe
    Kuhl, Christiane K.
    INVESTIGATIVE RADIOLOGY, 2013, 48 (04) : 200 - 205
  • [34] Promoting neuronal regeneration using extracellular vesicles loaded with superparamagnetic iron oxide nanoparticles
    Jenni Neubert
    Jana Glumm
    NeuralRegenerationResearch, 2016, 11 (01) : 61 - 63
  • [35] Promoting neuronal regeneration using extracellular vesicles loaded with superparamagnetic iron oxide nanoparticles
    Neubert, Jenni
    Glumm, Jana
    NEURAL REGENERATION RESEARCH, 2016, 11 (01) : 61 - 63
  • [36] Preparation and characterization of peptide modified ultrasmall superparamagnetic iron oxides used as tumor targeting MRI contrast agent
    Yin, Jie
    Yin, Guangfu
    Pu, Ximing
    Huang, Zhongbing
    Yao, Dajin
    RSC ADVANCES, 2019, 9 (34): : 19397 - 19407
  • [37] Surgical and radiological behavior of MRI-depictable mesh implants after TAPP repair: the IRONMAN study
    Lechner, M.
    Meissnitzer, M.
    Borhanian, K.
    Bittner, R.
    Kaufmann, R.
    Mayer, F.
    Jaeger, T.
    Mitterwallner, S.
    Emmanuel, K.
    Forstner, R.
    HERNIA, 2019, 23 (06) : 1133 - 1140
  • [38] Surgical and radiological behavior of MRI-depictable mesh implants after TAPP repair: the IRONMAN study
    M. Lechner
    M. Meissnitzer
    K. Borhanian
    R. Bittner
    R. Kaufmann
    F. Mayer
    T. Jäger
    S. Mitterwallner
    K. Emmanuel
    R. Forstner
    Hernia, 2019, 23 : 1133 - 1140
  • [39] MRI-Tracking of Dental Pulp Stem Cells In Vitro and In Vivo Using Dextran-Coated Superparamagnetic Iron Oxide Nanoparticles
    Zare, Shahrokh
    Mehrabani, Davood
    Jalli, Reza
    Moghadam, Mahdi Saeedi
    Manafi, Navid
    Mehrabani, Golshid
    Jamhiri, Iman
    Ahadian, Samad
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (09)
  • [40] Optimization, Characterization and in vivo Evaluation of Paclitaxel-Loaded Folate-Conjugated Superparamagnetic Iron Oxide Nanoparticles
    Gui, Gang
    Fan, Ziqi
    Ning, Yihuan
    Yuan, Cancan
    Zhang, Baolin
    Xu, Qin
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2021, 16 : 2283 - 2295