Sensitive Voltammetric Determination of Cadmium(II) with 8-Hydroxyquinoline and Ionic Liquid Modified Carbon Paste Electrode

被引:2
|
作者
Jia, Shaohui [1 ]
Gong, Shixing [2 ]
Cheng, Yong [2 ]
Wang, Huiyun [1 ]
Liu, Hejian [2 ]
Zhang, Bo [1 ]
Sun, Wei [2 ]
机构
[1] Jining Med Univ, Sch Pharm, Jining 272100, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
关键词
8-Hydroxyquinoline; 1-Ethyl-3-methylimidazoliam ethylsulphate; Cadmium; Differential pulse anodic stripping voltammetry; Carbon paste electrode; STRIPPING VOLTAMMETRY; ELECTROCHEMICAL DETECTION; PERIPHERAL-BLOOD; FILM; LEAD(II); ANTIMONY; SPECTROMETRY; EXTRACTION; CHLORIDE; COPPER;
D O I
10.1002/jccs.201400177
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this paper, 8-hydroxyquinoline (HQ) and ionic liquid (IL) modified carbon paste electrode was fabricated and used for the sensitive determination of cadmium(II) with differential pulse anodic stripping voltammetry (DPASV). The modified electrode was prepared by the addition of HQ and IL 1-ethyl-3-methylimidazoliam ethylsulphate as the modifiers into the traditional carbon paste mixture. Cd(II) was preconcentrated and reduced on the surface of the modified electrode at the potential of -1.0 V (vs. SCE) by the co-contributions from the formation of HQ-Cd(II) complex and the accumulation effect of IL. Then the reduced Cd on the electrode surface was reoxidized by DPASV with a sensitive oxidation peak appeared at -0.79 V (vs. SCE). Under the optimal conditions, the oxidation peak current was proportional to the Cd(II) concentration in the range from 0.03 to 2.0 mu mol/L with the detection limit as 5.0 nmol/L (3 sigma). The proposed method was successfully applied to the water samples detection with the recovery in the range from 95.6% to 96.6%.
引用
收藏
页码:1217 / 1222
页数:6
相关论文
共 50 条
  • [41] Sensitive Voltammetric Determination of Methyl Parathion Using a Carbon Paste Electrode Modified with Mesoporous Zirconia
    Tan, Xiaohong
    Li, Buhai
    Zhan, Guoqing
    Li, Chunya
    ELECTROANALYSIS, 2010, 22 (02) : 151 - 154
  • [42] Voltammetric determination of isoproterenol using multiwall carbon nanotubes-ionic liquid paste electrode
    Ensafi, Ali A.
    Karimi-Maleh, H.
    DRUG TESTING AND ANALYSIS, 2011, 3 (05) : 325 - 330
  • [43] Sensitive Detection of 8-Hydroxyquinoline in Cosmetics by Using a Poly(tannic acid)-Modified Glassy Carbon Electrode
    Gao, Zhimin
    Zeng, Qiang
    Wang, Min
    Wang, Lishi
    CHEMISTRYSELECT, 2022, 7 (16):
  • [44] Application of ionic liquid modified carbon ceramic electrode for the sensitive voltammetric detection of rutin
    Zhan, Tianrong
    Sun, Xiaoying
    Wang, Xiuzhen
    Sun, Wei
    Hou, Wanguo
    TALANTA, 2010, 82 (05) : 1853 - 1857
  • [45] Tetrabutylammonium Chloride Modified Carbon Paste Electrode for Rapid and Highly Sensitive Voltammetric Determination of Carbendazim
    Sekuljica, Sanja
    Guzsvany, Valeria
    Kalcher, Kurt
    Anojcic, Jasmina
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (13)
  • [46] Highly Sensitive Electrocatalytic Determination of Formaldehyde Using a Ni/Ionic Liquid Modified Carbon Nanotube Paste Electrode
    Zarei, Ebrahim
    Jamali, Mohammad Reza
    Ahmadi, Farideh
    BULLETIN OF CHEMICAL REACTION ENGINEERING AND CATALYSIS, 2018, 13 (03): : 529 - 542
  • [47] Electrochemical Behaviors and Sensitive Determination of Guanosine-5′-monophosphate on Ionic Liquid Modified Carbon Paste Electrode
    Sun, Wei
    Xu, Li
    Liu, Jun
    Wang, Xiuzhen
    Hu, Song
    Xiang, Jun
    CROATICA CHEMICA ACTA, 2013, 86 (02) : 129 - 135
  • [48] Fabrication of gallium hexacyanoferrate modified carbon ionic liquid paste electrode for sensitive determination of hydrogen peroxide and glucose
    Haghighi, Behzad
    Khosravi, Mehdi
    Barati, Ali
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 40 : 204 - 211
  • [49] Voltammetric behavior and determination of tanshinone II A at carbon paste electrode
    Tian Xinjuan
    Song Junfeng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (09) : 1283 - 1286
  • [50] Highly defective mesoporous carbon - ionic liquid paste electrode as sensitive voltammetric sensor for determination of chlorogenic acid in herbal extracts
    Mohammadi, Nourali
    Najafi, Mostafa
    Adeh, Narmin Bahrami
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 838 - 846