Sensitive Voltammetric Determination of Cadmium(II) with 8-Hydroxyquinoline and Ionic Liquid Modified Carbon Paste Electrode

被引:2
|
作者
Jia, Shaohui [1 ]
Gong, Shixing [2 ]
Cheng, Yong [2 ]
Wang, Huiyun [1 ]
Liu, Hejian [2 ]
Zhang, Bo [1 ]
Sun, Wei [2 ]
机构
[1] Jining Med Univ, Sch Pharm, Jining 272100, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
关键词
8-Hydroxyquinoline; 1-Ethyl-3-methylimidazoliam ethylsulphate; Cadmium; Differential pulse anodic stripping voltammetry; Carbon paste electrode; STRIPPING VOLTAMMETRY; ELECTROCHEMICAL DETECTION; PERIPHERAL-BLOOD; FILM; LEAD(II); ANTIMONY; SPECTROMETRY; EXTRACTION; CHLORIDE; COPPER;
D O I
10.1002/jccs.201400177
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this paper, 8-hydroxyquinoline (HQ) and ionic liquid (IL) modified carbon paste electrode was fabricated and used for the sensitive determination of cadmium(II) with differential pulse anodic stripping voltammetry (DPASV). The modified electrode was prepared by the addition of HQ and IL 1-ethyl-3-methylimidazoliam ethylsulphate as the modifiers into the traditional carbon paste mixture. Cd(II) was preconcentrated and reduced on the surface of the modified electrode at the potential of -1.0 V (vs. SCE) by the co-contributions from the formation of HQ-Cd(II) complex and the accumulation effect of IL. Then the reduced Cd on the electrode surface was reoxidized by DPASV with a sensitive oxidation peak appeared at -0.79 V (vs. SCE). Under the optimal conditions, the oxidation peak current was proportional to the Cd(II) concentration in the range from 0.03 to 2.0 mu mol/L with the detection limit as 5.0 nmol/L (3 sigma). The proposed method was successfully applied to the water samples detection with the recovery in the range from 95.6% to 96.6%.
引用
收藏
页码:1217 / 1222
页数:6
相关论文
共 50 条
  • [21] Determination of Carbendazim by an Ionic Liquid-Modified Carbon Paste Electrode
    Dordevic, Jelena S.
    Maksimovic, Vesna M.
    Gadzuric, Slobodan B.
    Trtic-Petrovic, Tatjana M.
    ANALYTICAL LETTERS, 2017, 50 (07) : 1075 - 1090
  • [22] Sensitive voltammetric determination of xanthinol nicotinate at a carbon nanotubes-ionic liquid gel modified electrode
    Bao, XiaoYu
    Tang, Yu Feng
    Yang, Hao
    Chen, Xin
    CHINESE CHEMICAL LETTERS, 2009, 20 (07) : 849 - 851
  • [24] A sensitive and simple modified zeolitic carbon paste electrode for indirect voltammetric determination of nitrate
    Nosuhi, Motahare
    Nezamzadeh-Ejhieh, Alireza
    IONICS, 2018, 24 (07) : 2135 - 2145
  • [25] A sensitive and simple modified zeolitic carbon paste electrode for indirect voltammetric determination of nitrate
    Motahare Nosuhi
    Alireza Nezamzadeh-Ejhieh
    Ionics, 2018, 24 : 2135 - 2145
  • [26] The voltammetric sensor for sensitive determination of 8-hydroxyquinoline based on MWNTs/Nafion/GCE
    Zhou Yuanyuan
    Li Song
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2011, 5 (09): : 924 - 927
  • [27] Single-walled carbon nanotube-ionic liquid paste electrode for the sensitive voltammetric determination of folic acid
    Xiao, Fei
    Ruan, Changping
    Liu, Lihong
    Yan, Rui
    Zhao, Faqiong
    Zeng, Baizhao
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) : 895 - 901
  • [28] Voltammetric determination of xanthine with a single-walled carbon nanotube-ionic liquid paste modified glassy carbon electrode
    Xiao, Fei
    Ruan, Changping
    Li, Jiangwen
    Liu, Lihong
    Zhao, Faqiong
    Zeng, Baizhao
    ELECTROANALYSIS, 2008, 20 (04) : 361 - 366
  • [29] Application of MnO2 Nanorod-Ionic Liquid Modified Carbon Paste Electrode for the Voltammetric Determination of Sulfanilamide
    Beitollahi, Hadi
    Tajik, Somayeh
    Di Bartolomeo, Antonio
    MICROMACHINES, 2022, 13 (04)
  • [30] Maize tassel-modified carbon paste electrode for voltammetric determination of Cu(II)
    Moyo, Mambo
    Okonkwo, Jonathan O.
    Agyei, Nana M.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2014, 186 (08) : 4807 - 4817