Determination of Carbendazim by an Ionic Liquid-Modified Carbon Paste Electrode

被引:16
|
作者
Dordevic, Jelena S. [1 ]
Maksimovic, Vesna M. [2 ]
Gadzuric, Slobodan B. [3 ]
Trtic-Petrovic, Tatjana M. [1 ]
机构
[1] Univ Belgrade, Vinca Inst Nucl Sci, Phys Lab, Belgrade, Serbia
[2] Univ Belgrade, Vinca Inst Nucl Sci, Mat Sci Lab, Belgrade, Serbia
[3] Univ Novi Sad, Dept Chem Biochem & Environm Protect, Fac Sci, Novi Sad, Serbia
关键词
Carbendazim; carbon paste electrodes; differential pulse voltammetry; electrochemistry; ionic liquids; ADSORPTIVE STRIPPING VOLTAMMETRY; TRICRESYL PHOSPHATE; FOOD SAMPLES; SOIL; COMPOSITE; RESIDUES; LINURON; SENSORS; MODEL; WATER;
D O I
10.1080/00032719.2016.1210615
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for the electroanalytical determination of carbendazim is reported using a novel ionic liquid-based carbon paste electrode. 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, and 1-butyl-1-methylpyrrolidinium bis(trifluoromethyl-sulfonyl)imide were used as additives in the paste for electrode fabrication. The electrodes were characterized by cyclic voltammetry of the "http://www.w3.org/1999/xlink" couple and scanning electron microscopy. The carbon paste electrode containing 19% 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide was selected for the electrochemical determination of carbendazim by differential pulse adsorptive stripping voltammetry. The influence of electrolyte pH, accumulation potential and time, and the presence of selected pesticides on electrochemical behavior of carbendazim were characterized. The optimal conditions for differential pulse adsorptive stripping voltammetry of carbendazim were determined to be a pH 5.0 Britton-Robinson buffer, an accumulation potential of -0.05V, an accumulation time of 120s, a start potential of -0.10V vs. the reference; an end potential of +1.30V, and a scan rate of 0.050Vs(-1). The linear dynamic range of the method was from 0.010 to 0.247mgL(-1) with a correlation coefficient of 0.9995. The recovery was 104.1% in fortified tap water, demonstrating its suitability for the analysis of water.
引用
收藏
页码:1075 / 1090
页数:16
相关论文
共 50 条
  • [1] Electrochemical determination of carbendazim in grapes and their derivatives by an ionic liquid-modified carbon paste electrode
    de Macedo, Jose Fernando
    Alves, Anderson A. C.
    Sant'Anna, Mercia V. S.
    Cunha, Frederico G. C.
    Oliveira, Gerlon de A. R.
    Liao, Luciano M.
    Sussuchi, Eliana Midori
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2022, 52 (04) : 729 - 742
  • [2] Electrochemical determination of carbendazim in grapes and their derivatives by an ionic liquid-modified carbon paste electrode
    José Fernando de Macedo
    Anderson A. C. Alves
    Mércia V. S. Sant’Anna
    Frederico G. C. Cunha
    Gerlon de A. R. Oliveira
    Luciano M. Lião
    Eliana Midori Sussuchi
    [J]. Journal of Applied Electrochemistry, 2022, 52 : 729 - 742
  • [3] Electrochemical behavior of labetalol at an ionic liquid-modified carbon paste electrode and its electrochemical determination
    Zhang, Yan-Mei
    Duan, Cheng-Qian
    Gao, Zuo-Ning
    [J]. JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2013, 78 (02) : 281 - 294
  • [4] Sensitive voltammetric determination of diclofenac using room-temperature ionic liquid-modified carbon nanotubes paste electrode
    Ensafi, Ali A.
    Izadi, Maedeh
    Karimi-Maleh, Hassan
    [J]. IONICS, 2013, 19 (01) : 137 - 144
  • [5] Sensitive voltammetric determination of diclofenac using room-temperature ionic liquid-modified carbon nanotubes paste electrode
    Ali A. Ensafi
    Maedeh Izadi
    Hassan Karimi-Maleh
    [J]. Ionics, 2013, 19 : 137 - 144
  • [6] Direct Electrochemistry of Hemoglobin in Chitosan/Multiwalled Carbon Nanotubes/Ionic Liquid-Modified Carbon-Paste Electrode
    Sun, Wei
    Zhai, Ziqin
    Li, Xiaoqing
    Qu, Lining
    Zhan, Tianrong
    Jiao, Kui
    [J]. ANALYTICAL LETTERS, 2009, 42 (15) : 2460 - 2473
  • [7] Highly sensitive electrochemical sensor based on pyrrolidinium ionic liquid modified ordered mesoporous carbon paste electrode for determination of carbendazim
    Ya, Yu
    Wang, Tianshun
    Xie, Liping
    Zhu, Junjie
    Tang, Li
    Ning, Dejiao
    Yan, Feiyan
    [J]. ANALYTICAL METHODS, 2015, 7 (04) : 1493 - 1498
  • [8] Electrochemical Determination of Brilliant Blue and Tartrazine Based on an Ionic Liquid-Modified Expanded Graphite Paste Electrode
    Wang, Wenchang
    Chen, Ye
    Zhang, Jing
    Wang, Xue
    Chen, Zhidong
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2015, 98 (03) : 817 - 821
  • [9] Sensitive voltammetric determination of rutin at an ionic liquid modified carbon paste electrode
    Zhanga, Ya
    Zhenga, Jianbin
    [J]. TALANTA, 2008, 77 (01) : 325 - 330
  • [10] Comparative investigation on electrochemical behavior of hydroquinone at carbon ionic liquid electrode, ionic liquid modified carbon paste electrode and carbon paste electrode
    Zhang, Ya
    Zheng, Jian Bin