Highly defective mesoporous carbon - ionic liquid paste electrode as sensitive voltammetric sensor for determination of chlorogenic acid in herbal extracts

被引:52
|
作者
Mohammadi, Nourali [1 ]
Najafi, Mostafa [2 ]
Adeh, Narmin Bahrami [1 ]
机构
[1] Iranian Res & Dev Ctr Chem Ind IRDCI, Acad Ctr Educ Culture & Res, Karaj, Iran
[2] Imam Hossein Univ, Fac Sci, Dept Chem, Tehran 16597, Iran
关键词
Defective mesoporous carbon; Ionic liquid; Paste electrode; Chlorogenic acid; Herbal extract; ELECTROCHEMICAL SENSOR; PHENOLIC-ACIDS; GRAPHENE; ADSORPTION; QUANTIFICATION; DIFFUSION; REDUCTION; DENSITY; HPLC;
D O I
10.1016/j.snb.2016.12.070
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this report, the preparation of a modified carbon paste electrode based on highly defective mesoporous carbon (DMC) and room temperature ionic liquid 1-Butyl-3-methylimidazolium hexafluorophosphate (BMIM.PF6) was described for sensitive voltammetric detection of chlorogenic acid (CGA) in herbal extracts. DMC with desired defective structure was synthesized via a facile method using nanosilica as a hard template, sucrose as a carbon source, and KNO3 as a defect causing agent. The characteristics of modified electrode (IL/DMC/PE) were investigated by cyclic voltammetry, electrochemical impedance spectroscopy and chronocoulometry. The electrochemical parameters of CGA on the surface of modified electrode were determined with the results of the charge transfer coefficient (at), the number of electron transfer (n), the electrode reaction rate constant (k(s)) and saturating absorption capacity as 0.5, 2, 3.1 s(-1) and 1.42 x 10(-9) mol cm(-2) respectively. The proposed sensor exhibited a remarkably enhanced effectiveness toward the electrochemical reaction of CGA in aqueous solution. The electrocatalytic behavior was further exploited as a sensitive detection scheme for the CGA determination by Square wave voltammetry (SWV). Under optimized conditions, the linear response range and detection limit were found to be 2 x 10(-8)-2.5 x 10(-6) mol and 1 x 10(-8) mol L-1 (S/N =3) respectively. The method was successfully applied for determination of CGA in extracts of Calendula officinalis and Echinacea purpurea. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:838 / 846
页数:9
相关论文
共 50 条
  • [1] A highly defective mesoporous carbon - ionic liquid paste electrode toward the sensitive electrochemical determination of rutin
    Mohammadi, Nourali
    Adeh, Narmin Bahrami
    Najafi, Mostafa
    ANALYTICAL METHODS, 2017, 9 (01) : 84 - 93
  • [2] Sensitive voltammetric determination of rutin at an ionic liquid modified carbon paste electrode
    Zhanga, Ya
    Zhenga, Jianbin
    TALANTA, 2008, 77 (01) : 325 - 330
  • [3] Highly sensitive electrochemical sensor based on pyrrolidinium ionic liquid modified ordered mesoporous carbon paste electrode for determination of carbendazim
    Ya, Yu
    Wang, Tianshun
    Xie, Liping
    Zhu, Junjie
    Tang, Li
    Ning, Dejiao
    Yan, Feiyan
    ANALYTICAL METHODS, 2015, 7 (04) : 1493 - 1498
  • [4] Single-walled carbon nanotube-ionic liquid paste electrode for the sensitive voltammetric determination of folic acid
    Xiao, Fei
    Ruan, Changping
    Liu, Lihong
    Yan, Rui
    Zhao, Faqiong
    Zeng, Baizhao
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) : 895 - 901
  • [5] Electrochemical Determination of Riboflavin by an Ionic Liquid Modified Carbon Paste Electrode as a Sensitive Sensor
    Zarei, Ebrahim
    Jamali, Mohammad Reza
    Bagheri, Jaber
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 642 - 657
  • [6] A new voltammetric sensor according to graphene quantum dots/ionic liquid modified carbon paste electrode for amaranth sensitive determination
    Akbari, Sedighe
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (03) : 789 - 803
  • [7] Development of a highly sensitive voltammetric sensor for the detection of folic acid by using MoS2 and ionic liquid-modified carbon paste electrode
    Nejad, Hadi Soltani
    Nejad, Fariba Garkani
    Beitollahi, Hadi
    ADMET AND DMPK, 2023, 11 (03): : 361 - 371
  • [8] Application of ZnO/CNTs Nanocomposite Ionic Liquid Paste Electrode as a Sensitive Voltammetric Sensor for Determination of Ascorbic Acid in Food Samples
    Bijad, Majede
    Karimi-Maleh, Hassan
    Khalilzadeh, Mohammad A.
    FOOD ANALYTICAL METHODS, 2013, 6 (06) : 1639 - 1647
  • [9] Application of ZnO/CNTs Nanocomposite Ionic Liquid Paste Electrode as a Sensitive Voltammetric Sensor for Determination of Ascorbic Acid in Food Samples
    Majede Bijad
    Hassan Karimi-Maleh
    Mohammad A. Khalilzadeh
    Food Analytical Methods, 2013, 6 : 1639 - 1647
  • [10] NiO/CNTs Nanocomposite Modified Ionic Liquid Carbon Paste Electrode as a Voltammetric Sensor for Determination of Quercetin
    Gupta, Vinod Kumar
    Golestani, Fereshteh
    Ahmadzadeh, Saeid
    Karimi-Maleh, Hassan
    Fazli, Gozal
    Khosravi, Sahebe
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (04): : 3657 - 3667