GPU-accelerated compressed-sensing (CS) image reconstruction in chest digital tomosynthesis (CDT) using CUDA programming

被引:0
|
作者
Choi, Sunghoon [1 ]
Leer, Haenghwa [1 ]
Lee, Donghoon [2 ]
Choi, Seungyeon [2 ]
Shin, Jungwook [3 ]
Jang, Woojin [3 ]
Seo, Chang-Woo [1 ]
Kim, Hee-Joung [1 ,2 ]
机构
[1] Yonsei Univ, Coll Hlth Sci, Dept Radiol Sci, Wonju, South Korea
[2] Yonsei Univ, Coll Hlth Sci, Dept Radiat Convergence Engn, Wonju, South Korea
[3] LISTEM Corp, 94 Donghwagongdan Ro, Wonju, South Korea
关键词
BEAM COMPUTED-TOMOGRAPHY; BREAST TOMOSYNTHESIS; IMPLEMENTATION; MAMMOGRAPHY; ART;
D O I
10.1117/12.2254206
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A compressed-sensing (CS) technique has been rapidly applied in medical imaging field for retrieving volumetric data from highly under-sampled projections. Among many variant forms, CS technique based on a total-variation (TV) regularization strategy shows fairly reasonable results in cone-beam geometry. In this study, we implemented the TV-based CS image reconstruction strategy in our prototype chest digital tomosynthesis (CDT) R/F system. Due to the iterative nature of time consuming processes in solving a cost function, we took advantage of parallel computing using graphics processing units (GPU) by the compute unified device architecture (CUDA) programming to accelerate our algorithm. In order to compare the algorithmic performance of our proposed CS algorithm, conventional filtered back-projection (FBP) and simultaneous algebraic reconstruction technique (SART) reconstruction schemes were also studied. The results indicated that the CS produced better contrast-to-noise ratios (CNRs) in the physical phantom images (Teflon region-of-interest) by factors of 3.91 and 1.93 than FBP and SART images, respectively. The resulted human chest phantom images including lung nodules with different diameters also showed better visual appearance in the CS images. Our proposed GPU-accelerated CS reconstruction scheme could produce volumetric data up to 80 times than CPU programming. Total elapsed time for producing 50 coronal planes with 1024x1024 image matrix using 41 projection views were 216.74 seconds for proposed CS algorithms on our GPU programming, which could match the clinically feasible time (similar to 3 min). Consequently, our results demonstrated that the proposed CS method showed a potential of additional dose reduction in digital tomosynthesis with reasonable image quality in a fast time.
引用
收藏
页数:7
相关论文
共 41 条
  • [1] Feasibility Study of Four-Dimensional Digital Tomosynthesis Using GPU-Accelerated Compressed-Sensing (CS) Image Reconstruction for Faster Tumor Localization
    Choi, S.
    Hsieh, S.
    Lee, D.
    Choi, S.
    Kim, H.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E549 - E550
  • [2] Development of a chest digital tomosynthesis R/F system and implementation of low-dose GPU-accelerated compressed sensing (CS) image reconstruction
    Choi, Sunghoon
    Lee, Haenghwa
    Lee, Donghoon
    Choi, Seungyeon
    Lee, Chang-Lae
    Kwon, Woocheol
    Shin, Jungwook
    Seo, Chang-Woo
    Kim, Hee-Joung
    [J]. MEDICAL PHYSICS, 2018, 45 (05) : 1871 - 1888
  • [3] Image reconstruction in region-of-interest (or interior) digital tomosynthesis (DTS) based on compressed-sensing (CS)
    Park, Soyoung
    Kim, Guna
    Cho, Hyosung
    Je, Uikyu
    Park, Chulkyu
    Kim, Kyuseok
    Lim, Hyunwoo
    Lee, Dongyeon
    Lee, Hunwoo
    Kang, Seokyoon
    Park, Jeongeun
    Woo, Taeho
    Lee, Minsik
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2017, 151 : 151 - 158
  • [4] Development of a prototype chest digital tomosynthesis (CDT) R/F system with fast image reconstruction using graphics processing unit (GPU) programming
    Choi, Sunghoon
    Lee, Seungwan
    Lee, Haenghwa
    Lee, Donghoon
    Choi, Seungyeon
    Shin, Jungwook
    Seo, Chang-Woo
    Kim, Hee-Joung
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 848 : 174 - 181
  • [5] Evaluation of the image quality in digital breast tomosynthesis (DBT) employed with a compressed-sensing (CS)-based reconstruction algorithm by using the mammographic accreditation phantom
    Park, Yeonok
    Cho, Heemoon
    Je, Uikyu
    Cho, Hyosung
    Park, Chulkyu
    Lim, Hyunwoo
    Kim, Kyuseok
    Kim, Guna
    Park, Soyoung
    Woo, Taeho
    Choi, Sungil
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 804 : 72 - 78
  • [6] Dynamically-Collimated Digital Tomosynthesis Reconstruction by Using a Compressed-Sensing Based Algorithm
    Soyoung Park
    Guna Kim
    Hyosung Cho
    Changwoo Seo
    Minsik Lee
    [J]. Journal of the Korean Physical Society, 2020, 76 : 66 - 72
  • [7] Dynamically-Collimated Digital Tomosynthesis Reconstruction by Using a Compressed-Sensing Based Algorithm
    Park, Soyoung
    Kim, Guna
    Cho, Hyosung
    Seo, Changwoo
    Lee, Minsik
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (01) : 66 - 72
  • [8] Fast low-dose compressed-sensing (CS) image reconstruction in four-dimensional digital tomosynthesis using on-board imager (OBI)
    Choi, Sunghoon
    Hsieh, Scott S.
    Seo, Chang-Woo
    Kim, Hee-Joung
    [J]. MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [9] Improvement of Image Characteristics in Digital Breast Tomosynthesis by Incorporating a Compressed-sensing (CS) Deblurring Framework: Simulation Study
    Cho, Heemoon
    Kim, Kyuseok
    Cho, Hyosung
    Lim, Hyunwoo
    Park, Yeonok
    [J]. PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON BIOLOGICAL SCIENCES AND TECHNOLOGY, 2016, : 183 - 186
  • [10] Improvement of image performance in digital breast tomosynthesis (DBT) by incorporating a compressed-sensing (CS)-based deblurring scheme
    Kim, Kyuseok
    Park, Yeonok
    Cho, Heemoon
    Cho, Hyosung
    Je, Uikyu
    Park, Chulkyu
    Lim, Hyunwoo
    Park, Soyoung
    Woo, Taeho
    Choi, Sungil
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2016, 127 : 147 - 154