Development of a chest digital tomosynthesis R/F system and implementation of low-dose GPU-accelerated compressed sensing (CS) image reconstruction

被引:6
|
作者
Choi, Sunghoon [1 ]
Lee, Haenghwa [1 ]
Lee, Donghoon [2 ]
Choi, Seungyeon [2 ]
Lee, Chang-Lae [1 ]
Kwon, Woocheol [3 ]
Shin, Jungwook [4 ]
Seo, Chang-Woo [1 ]
Kim, Hee-Joung [1 ,2 ]
机构
[1] Yonsei Univ, Dept Radiol Sci, 1 Yonseidae Gil, Wonju 26493, South Korea
[2] Yonsei Univ, Dept Radiat Convergence Engn, 1 Yonseidae Gil, Wonju 26493, South Korea
[3] Wonju Severance Christian Hosp, Dept Radiol, 20 Ilsan Ro, Wonju 26426, South Korea
[4] LISTEM Corp, 94 Donghwagongdan Ro, Wonju, South Korea
关键词
development of a digital tomosynthesis R; F system; dose reduction; fast image reconstruction; GPU; BEAM COMPUTED-TOMOGRAPHY; DIAGNOSTIC-PERFORMANCE; HUMAN OBSERVER; RADIOGRAPHY; CT; PROJECTION; ALGORITHM; CANCER; NODULE; MODEL;
D O I
10.1002/mp.12843
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThis work describes the hardware and software developments of a prototype chest digital tomosynthesis (CDT) R/F system. The purpose of this study was to validate the developed system for its possible clinical application on low-dose chest tomosynthesis imaging. MethodsThe prototype CDT R/F system was operated by carefully controlling the electromechanical subsystems through a synchronized interface. Once a command signal was delivered by the user, a tomosynthesis sweep started to acquire 81 projection views (PVs) in a limited angular range of 20 degrees. Among the full projection dataset of 81 images, several sets of 21 (quarter view) and 41 (half view) images with equally spaced angle steps were selected to represent a sparse view condition. GPU-accelerated and total-variation (TV) regularization strategy-based compressed sensing (CS) image reconstruction was implemented. The imaged objects were a flat-field using a copper filter to measure the noise power spectrum (NPS), a Catphan((R)) CTP682 quality assurance (QA) phantom to measure a task-based modulation transfer function (MTFTask) of three different cylinders' edge, and an anthropomorphic chest phantom with inserted lung nodules. The authors also verified the accelerated computing power over CPU programming by checking the elapsed time required for the CS method. The resultant absorbed and effective doses that were delivered to the chest phantom from two-view digital radiographic projections, helical computed tomography (CT), and the prototype CDT system were compared. ResultsThe prototype CDT system was successfully operated, showing little geometric error with fast rise and fall times of R/F x-ray pulse less than 2 and 10 ms, respectively. The in-plane NPS presented essential symmetric patterns as predicted by the central slice theorem. The NPS images from 21 PVs were provided quite different pattern against 41 and 81 PVs due to aliased noise. The voxel variance values which summed all NPS intensities were inversely proportional to the number of PVs, and the CS method gave much lower voxel variance by the factors of 3.97-6.43 and 2.28-3.36 compared to filtered backprojection (FBP) and 20 iterations of simultaneous algebraic reconstruction technique (SART). The spatial frequencies of the f(50) at which the MTFTask reduced to 50% were 1.50, 1.55, and 1.67 cycles/mm for FBP, SART, and CS methods, respectively, in the case of Bone 20% cylinder using 41 views. A variety of ranges of TV reconstruction parameters were implemented during the CS method and we could observe that the NPS and MTFTask preserved best when the regularization and TV smoothing parameters and were in a range of 0.001-0.1. For the chest phantom data, the signal difference to noise ratios (SDNRs) were higher in the proposed CS scheme images than in the FBP and SART, showing the enhanced rate of 1.05-1.43 for half view imaging. The total averaged reconstruction time during 20 iterations of the CS scheme was 124.68 s, which could match-up a clinically feasible time (<3 min). This computing time represented an enhanced speed 386 times greater than CPU programming. The total amounts of estimated effective doses were 0.12, 0.53 (half view), and 2.56 mSv for two-view radiographs, the prototype CDT system, and helical CT, respectively, showing 4.49 times higher than conventional radiography and 4.83 times lower than a CT exam, respectively. ConclusionsThe current work describes the development and performance assessment of both hardware and software for tomosynthesis applications. The authors observed reasonable outcomes by showing a potential for low-dose application in CDT imaging using GPU acceleration.
引用
收藏
页码:1871 / 1888
页数:18
相关论文
共 25 条
  • [1] GPU-accelerated compressed-sensing (CS) image reconstruction in chest digital tomosynthesis (CDT) using CUDA programming
    Choi, Sunghoon
    Leer, Haenghwa
    Lee, Donghoon
    Choi, Seungyeon
    Shin, Jungwook
    Jang, Woojin
    Seo, Chang-Woo
    Kim, Hee-Joung
    [J]. MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [2] Feasibility Study of Four-Dimensional Digital Tomosynthesis Using GPU-Accelerated Compressed-Sensing (CS) Image Reconstruction for Faster Tumor Localization
    Choi, S.
    Hsieh, S.
    Lee, D.
    Choi, S.
    Kim, H.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E549 - E550
  • [3] Fast low-dose compressed-sensing (CS) image reconstruction in four-dimensional digital tomosynthesis using on-board imager (OBI)
    Choi, Sunghoon
    Hsieh, Scott S.
    Seo, Chang-Woo
    Kim, Hee-Joung
    [J]. MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [4] Development of a prototype chest digital tomosynthesis (CDT) R/F system with fast image reconstruction using graphics processing unit (GPU) programming
    Choi, Sunghoon
    Lee, Seungwan
    Lee, Haenghwa
    Lee, Donghoon
    Choi, Seungyeon
    Shin, Jungwook
    Seo, Chang-Woo
    Kim, Hee-Joung
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 848 : 174 - 181
  • [5] Development of a prototype chest digital tomosynthesis R/F system
    Choi, Sunghoon
    Lee, Haenghwa
    Lee, Donghoon
    Choi, Seungyeon
    Shin, Jungwook
    Jang, Woojin
    Seo, Chang-Woo
    Kim, Hee-Joung
    [J]. MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [6] A Feasibility Study of GPU-Accelerated Image Reconstruction with Distance-Driven Method in Digital Tomosynthesis Utilizing Rectilinear Geometry in the LINAC System
    Jo, Byungdu
    [J]. JOURNAL OF MAGNETICS, 2023, 28 (04) : 403 - 408
  • [7] OVERVIEW OF A DIGITAL TOMOSYNTHESIS DEVELOPMENT: NEW APPROACHES FOR LOW-DOSE CHEST IMAGING
    Horvath, Akos
    Wolf, Peter
    Nagy, Janos
    Kelemen, Attila
    Horvath, Gabor
    Hadhazi, Daniel
    Horvath, Aron
    Czetenyi, Benjamin
    Sutto, Zoltan
    Szondy, Klara
    [J]. RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 171 - 176
  • [8] Compressed Sensing for Low-dose 4D CBCT Image Reconstruction
    Choi, K.
    Li, T.
    Suh, T.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S43 - S44
  • [9] Image reconstruction in region-of-interest (or interior) digital tomosynthesis (DTS) based on compressed-sensing (CS)
    Park, Soyoung
    Kim, Guna
    Cho, Hyosung
    Je, Uikyu
    Park, Chulkyu
    Kim, Kyuseok
    Lim, Hyunwoo
    Lee, Dongyeon
    Lee, Hunwoo
    Kang, Seokyoon
    Park, Jeongeun
    Woo, Taeho
    Lee, Minsik
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2017, 151 : 151 - 158
  • [10] Compressed-sensing (CS)-based digital breast tomosynthesis (DBT) reconstruction for low-dose, accurate 3D breast X-ray imaging
    Park, Yeonok
    Cho, Hyosung
    Je, Uikyu
    Hong, Daeki
    Lee, Minsik
    Park, Chulkyu
    Cho, Heemoon
    Choi, Sungil
    Koo, Yangseo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (04) : 565 - 571