Image reconstruction in region-of-interest (or interior) digital tomosynthesis (DTS) based on compressed-sensing (CS)

被引:2
|
作者
Park, Soyoung [1 ]
Kim, Guna [1 ]
Cho, Hyosung [1 ]
Je, Uikyu [1 ]
Park, Chulkyu [1 ]
Kim, Kyuseok [1 ]
Lim, Hyunwoo [1 ]
Lee, Dongyeon [1 ]
Lee, Hunwoo [1 ]
Kang, Seokyoon [1 ]
Park, Jeongeun [1 ]
Woo, Taeho [1 ]
Lee, Minsik [2 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, 1 Yonseidae Gil, Wonju 26493, Gangwon Do, South Korea
[2] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
基金
新加坡国家研究基金会;
关键词
Region-of-interest; Digital tomosynthesis; Compressed-sensing; Dose reduction; COMPUTED-TOMOGRAPHY; OPTIMIZATION; SCAN;
D O I
10.1016/j.cmpb.2017.08.022
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Digital tomosynthesis (DTS) based on filtered-backprojection (FBP) reconstruction requires a full field-of-view (FOV) scan and relatively dense projections, which results in high doses for medical imaging purposes. To overcome these difficulties, we investigated region-of-interest (ROI) or interior DTS reconstruction where the x-ray beam span covers only a small ROI containing a target area. Methods: An iterative method based on compressed-sensing (CS) scheme was compared with the FBP-based algorithm for ROI-DTS reconstruction. We implemented both algorithms and performed a systematic simulation and experiments on body and skull phantoms. The image characteristics were evaluated and compared. Results: The CS-based algorithm yielded much better reconstruction quality in ROI-DTS compared to the FBP-based algorithm, preserving superior image homogeneity, edge sharpening, and in-plane resolution. The image characteristics of the CS-reconstructed images in ROI-DTS were not significantly different from those in full-FOV DTS. The measured CNR value of the CS-reconstructed ROI-DTS image was about 12.3, about 1.9 times larger than that of the FBP-reconstructed ROI-DTS image. Conclusions: ROI-DTS images of substantially high accuracy were obtained using the CS-based algorithm and at reduced imaging doses and less computational cost, compared to typical full-FOV DTS images. We expect that the proposed method will be useful for the development of new DTS systems. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:151 / 158
页数:8
相关论文
共 50 条
  • [1] Application of a dual-resolution voxelization scheme to compressed-sensing (CS)-based iterative reconstruction in digital tomosynthesis (DTS)
    Park, S. Y.
    Kim, G. A.
    Cho, H. S.
    Park, C. K.
    Lee, D. Y.
    Lim, H. W.
    Lee, H. W.
    Kim, K. S.
    Kang, S. Y.
    Park, J. E.
    Kim, W. S.
    Jeon, D. H.
    Je, U. K.
    Woo, T. H.
    Oh, J. E.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 880 : 46 - 52
  • [2] Feasibility Study for Improving the Image Characteristics in Digital Tomosynthesis (DTS) Using a Compressed-Sensing (Cs)-Based Pre-Deblurring Scheme
    Kim, Kyuseok
    Park, Soyoung
    Kim, Guna
    Cho, Hyosung
    Je, Uikyu
    Park, Chulkyu
    Lim, Hyunwoo
    Lee, Dongyeon
    Lee, Hunwoo
    Park, Yeonok
    Woo, Taeho
    [J]. RESEARCH IN NONDESTRUCTIVE EVALUATION, 2018, 29 (02) : 109 - 121
  • [3] GPU-accelerated compressed-sensing (CS) image reconstruction in chest digital tomosynthesis (CDT) using CUDA programming
    Choi, Sunghoon
    Leer, Haenghwa
    Lee, Donghoon
    Choi, Seungyeon
    Shin, Jungwook
    Jang, Woojin
    Seo, Chang-Woo
    Kim, Hee-Joung
    [J]. MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [4] Improvement of image performance in digital breast tomosynthesis (DBT) by incorporating a compressed-sensing (CS)-based deblurring scheme
    Kim, Kyuseok
    Park, Yeonok
    Cho, Heemoon
    Cho, Hyosung
    Je, Uikyu
    Park, Chulkyu
    Lim, Hyunwoo
    Park, Soyoung
    Woo, Taeho
    Choi, Sungil
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2016, 127 : 147 - 154
  • [5] Scout-view assisted interior digital tomosynthesis (iDTS) based on compressed-sensing theory
    Park, S. Y.
    Kim, G. A.
    Cho, H. S.
    Seo, C. W.
    Je, U. K.
    Park, C. K.
    Lim, H. W.
    Kim, K. S.
    Lee, D. Y.
    Lee, H. W.
    Kang, S. Y.
    Park, J. E.
    Woo, T. H.
    Lee, M. S.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 141 : 29 - 35
  • [6] Evaluation of the image quality in digital breast tomosynthesis (DBT) employed with a compressed-sensing (CS)-based reconstruction algorithm by using the mammographic accreditation phantom
    Park, Yeonok
    Cho, Heemoon
    Je, Uikyu
    Cho, Hyosung
    Park, Chulkyu
    Lim, Hyunwoo
    Kim, Kyuseok
    Kim, Guna
    Park, Soyoung
    Woo, Taeho
    Choi, Sungil
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 804 : 72 - 78
  • [7] Dynamically-Collimated Digital Tomosynthesis Reconstruction by Using a Compressed-Sensing Based Algorithm
    Soyoung Park
    Guna Kim
    Hyosung Cho
    Changwoo Seo
    Minsik Lee
    [J]. Journal of the Korean Physical Society, 2020, 76 : 66 - 72
  • [8] Dynamically-Collimated Digital Tomosynthesis Reconstruction by Using a Compressed-Sensing Based Algorithm
    Park, Soyoung
    Kim, Guna
    Cho, Hyosung
    Seo, Changwoo
    Lee, Minsik
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (01) : 66 - 72
  • [9] Improvement of Image Characteristics in Digital Breast Tomosynthesis by Incorporating a Compressed-sensing (CS) Deblurring Framework: Simulation Study
    Cho, Heemoon
    Kim, Kyuseok
    Cho, Hyosung
    Lim, Hyunwoo
    Park, Yeonok
    [J]. PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON BIOLOGICAL SCIENCES AND TECHNOLOGY, 2016, : 183 - 186
  • [10] Application of a compressed-sensing (CS)-based deblurring scheme to digital tomosynthesis (DTS) for improved x-ray nondestructive testing: Simulation and experimental studies
    Kim, K. S.
    Park, S. Y.
    Kim, G. A.
    Cho, H. S.
    Je, U. K.
    Park, Y. O.
    Park, C. K.
    Lim, H. W.
    Woo, T. H.
    Park, S. M.
    Lee, H. W.
    Seo, C. W.
    [J]. OPTICS AND LASERS IN ENGINEERING, 2016, 86 : 255 - 263