Improvement of image performance in digital breast tomosynthesis (DBT) by incorporating a compressed-sensing (CS)-based deblurring scheme

被引:3
|
作者
Kim, Kyuseok [1 ]
Park, Yeonok [1 ]
Cho, Heemoon [1 ]
Cho, Hyosung [1 ]
Je, Uikyu [1 ]
Park, Chulkyu [1 ]
Lim, Hyunwoo [1 ]
Park, Soyoung [1 ]
Woo, Taeho [1 ]
Choi, Sungil [1 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, ITOMO Res Grp, Wonju 22071D, South Korea
关键词
Deblurring; Compressed-sensing (CS); Digital breast tomosynthesis (DBT); Filter kernel; MAMMOGRAPHY; RESTORATION;
D O I
10.1016/j.radphyschem.2016.06.025
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this work, we investigated a compressed-sensing (CS)-based deblurring scheme incorporated with the total-variation (TV) regularization penalty for image deblurring of high accuracy and adopted it into the image reconstruction in conventional digital breast tomosynthesis (DBT). We implemented the proposed algorithm and performed a systematic simulation to demonstrate its viability for improving the image performance in DBT as well as two-dimensional (2D) mammography. In the simulation, blurred noisy projection images of a 3D numerical breast phantom were generated by convolving their original (or exact) version by a designed 2D Gaussian filter kernel (standard deviation= 2 in pixel unit, kernel size = 11 x 11), followed by adding Gaussian noise (mean=0, variance=0.05), and deblurred by using the algorithm before performing the DBT reconstruction procedure. Here the projection images were taken with a half tomographic angle of theta=20 circle and an angle step of Delta theta=2 circle. We investigated the image performance of the reconstructed DBT images quantitatively in terms of the modulation and the slice-sensitive profile (SSP). (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:147 / 154
页数:8
相关论文
共 29 条
  • [1] Improvement of Image Characteristics in Digital Breast Tomosynthesis by Incorporating a Compressed-sensing (CS) Deblurring Framework: Simulation Study
    Cho, Heemoon
    Kim, Kyuseok
    Cho, Hyosung
    Lim, Hyunwoo
    Park, Yeonok
    [J]. PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON BIOLOGICAL SCIENCES AND TECHNOLOGY, 2016, : 183 - 186
  • [2] A blind-deblurring method based on a compressed-sensing scheme in digital breast tomosynthesis
    Kim, K.
    Kim, W.
    Kang, S.
    Park, C.
    Lee, D.
    Cho, H.
    Seo, C.
    Lim, H.
    Lee, H.
    Kim, G.
    Park, S.
    Park, J.
    Jeon, D.
    Lim, Y.
    Woo, T.
    Oh, J.
    [J]. OPTICS AND LASERS IN ENGINEERING, 2018, 110 : 228 - 235
  • [3] Feasibility Study for Improving the Image Characteristics in Digital Tomosynthesis (DTS) Using a Compressed-Sensing (Cs)-Based Pre-Deblurring Scheme
    Kim, Kyuseok
    Park, Soyoung
    Kim, Guna
    Cho, Hyosung
    Je, Uikyu
    Park, Chulkyu
    Lim, Hyunwoo
    Lee, Dongyeon
    Lee, Hunwoo
    Park, Yeonok
    Woo, Taeho
    [J]. RESEARCH IN NONDESTRUCTIVE EVALUATION, 2018, 29 (02) : 109 - 121
  • [4] Evaluation of the image quality in digital breast tomosynthesis (DBT) employed with a compressed-sensing (CS)-based reconstruction algorithm by using the mammographic accreditation phantom
    Park, Yeonok
    Cho, Heemoon
    Je, Uikyu
    Cho, Hyosung
    Park, Chulkyu
    Lim, Hyunwoo
    Kim, Kyuseok
    Kim, Guna
    Park, Soyoung
    Woo, Taeho
    Choi, Sungil
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 804 : 72 - 78
  • [5] Investigation of Reconstruction Quality in Digital Breast Tomosynthesis (DBT) Based on Compressed-sensing Algorithm and Synthesized 2D Breast Image
    Park, Yeonok
    Cho, Hyosung
    Hong, Daeki
    Je, Uikyu
    Park, Chulkyu
    Cho, Heemoon
    Lim, Hyunwoo
    Kim, Kyuseok
    Park, Soyoung
    Woo, Taeho
    Choi, Sungil
    [J]. 2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [6] Improvement of image characteristics in high-voltage computed tomography (CT) by applying a compressed-sensing (CS)-based image deblurring scheme
    Kim, Kyuseok
    Cho, Hyosung
    Je, Uikyu
    Park, Chulkyu
    Lim, Hyunwoo
    Kim, Guna
    Park, Soyoung
    Park, Yeonok
    Lee, Dongyeon
    Lee, Hunwoo
    Woo, Taeho
    [J]. NDT & E INTERNATIONAL, 2016, 84 : 11 - 19
  • [7] Image reconstruction in region-of-interest (or interior) digital tomosynthesis (DTS) based on compressed-sensing (CS)
    Park, Soyoung
    Kim, Guna
    Cho, Hyosung
    Je, Uikyu
    Park, Chulkyu
    Kim, Kyuseok
    Lim, Hyunwoo
    Lee, Dongyeon
    Lee, Hunwoo
    Kang, Seokyoon
    Park, Jeongeun
    Woo, Taeho
    Lee, Minsik
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2017, 151 : 151 - 158
  • [8] Application of a compressed-sensing (CS)-based deblurring scheme to digital tomosynthesis (DTS) for improved x-ray nondestructive testing: Simulation and experimental studies
    Kim, K. S.
    Park, S. Y.
    Kim, G. A.
    Cho, H. S.
    Je, U. K.
    Park, Y. O.
    Park, C. K.
    Lim, H. W.
    Woo, T. H.
    Park, S. M.
    Lee, H. W.
    Seo, C. W.
    [J]. OPTICS AND LASERS IN ENGINEERING, 2016, 86 : 255 - 263
  • [9] Compressed-sensing (CS)-based digital breast tomosynthesis (DBT) reconstruction for low-dose, accurate 3D breast X-ray imaging
    Park, Yeonok
    Cho, Hyosung
    Je, Uikyu
    Hong, Daeki
    Lee, Minsik
    Park, Chulkyu
    Cho, Heemoon
    Choi, Sungil
    Koo, Yangseo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (04) : 565 - 571
  • [10] Compressed-sensing (CS)-based digital breast tomosynthesis (DBT) reconstruction for low-dose, accurate 3D breast X-ray imaging
    Yeonok Park
    Hyosung Cho
    Uikyu Je
    Daeki Hong
    Minsik Lee
    Chulkyu Park
    Heemoon Cho
    Sungil Choi
    Yangseo Koo
    [J]. Journal of the Korean Physical Society, 2014, 65 : 565 - 571