GPU-accelerated compressed-sensing (CS) image reconstruction in chest digital tomosynthesis (CDT) using CUDA programming

被引:0
|
作者
Choi, Sunghoon [1 ]
Leer, Haenghwa [1 ]
Lee, Donghoon [2 ]
Choi, Seungyeon [2 ]
Shin, Jungwook [3 ]
Jang, Woojin [3 ]
Seo, Chang-Woo [1 ]
Kim, Hee-Joung [1 ,2 ]
机构
[1] Yonsei Univ, Coll Hlth Sci, Dept Radiol Sci, Wonju, South Korea
[2] Yonsei Univ, Coll Hlth Sci, Dept Radiat Convergence Engn, Wonju, South Korea
[3] LISTEM Corp, 94 Donghwagongdan Ro, Wonju, South Korea
关键词
BEAM COMPUTED-TOMOGRAPHY; BREAST TOMOSYNTHESIS; IMPLEMENTATION; MAMMOGRAPHY; ART;
D O I
10.1117/12.2254206
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A compressed-sensing (CS) technique has been rapidly applied in medical imaging field for retrieving volumetric data from highly under-sampled projections. Among many variant forms, CS technique based on a total-variation (TV) regularization strategy shows fairly reasonable results in cone-beam geometry. In this study, we implemented the TV-based CS image reconstruction strategy in our prototype chest digital tomosynthesis (CDT) R/F system. Due to the iterative nature of time consuming processes in solving a cost function, we took advantage of parallel computing using graphics processing units (GPU) by the compute unified device architecture (CUDA) programming to accelerate our algorithm. In order to compare the algorithmic performance of our proposed CS algorithm, conventional filtered back-projection (FBP) and simultaneous algebraic reconstruction technique (SART) reconstruction schemes were also studied. The results indicated that the CS produced better contrast-to-noise ratios (CNRs) in the physical phantom images (Teflon region-of-interest) by factors of 3.91 and 1.93 than FBP and SART images, respectively. The resulted human chest phantom images including lung nodules with different diameters also showed better visual appearance in the CS images. Our proposed GPU-accelerated CS reconstruction scheme could produce volumetric data up to 80 times than CPU programming. Total elapsed time for producing 50 coronal planes with 1024x1024 image matrix using 41 projection views were 216.74 seconds for proposed CS algorithms on our GPU programming, which could match the clinically feasible time (similar to 3 min). Consequently, our results demonstrated that the proposed CS method showed a potential of additional dose reduction in digital tomosynthesis with reasonable image quality in a fast time.
引用
收藏
页数:7
相关论文
共 42 条
  • [31] Experimental study on the application of a compressed-sensing (CS) algorithm to dental cone-beam CT (CBCT) for accurate, low-dose image reconstruction
    Oh, Jieun
    Cho, Hyosung
    Je, Uikyu
    Lee, Minsik
    Kim, Hyojeong
    Hong, Daeki
    Park, Yeonok
    Lee, Seonhwa
    Cho, Heemoon
    Choi, Sungil
    Koo, Yangseo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 62 (05) : 834 - 838
  • [32] Image Quality Evaluation of a Compressed-Sensing Algorithm for Image Reconstruction in Dedicated Cone-Beam Breast CT Using Offset-Detector
    Vedantham, S.
    Tseng, H.
    Karellas, A.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [33] Experimental study on the application of a compressed-sensing (CS) algorithm to dental cone-beam CT (CBCT) for accurate, low-dose image reconstruction
    Jieun Oh
    Hyosung Cho
    Uikyu Je
    Minsik Lee
    Hyojeong Kim
    Daeki Hong
    Yeonok Park
    Seonhwa Lee
    Heemoon Cho
    Sungil Choi
    Yangseo Koo
    [J]. Journal of the Korean Physical Society, 2013, 62 : 834 - 838
  • [34] An LED-Based structured illumination microscope using a digital micromirror device and GPU accelerated image reconstruction
    Aydin, Musa
    Uysalli, Yigit
    Ozgonul, Ekin
    Morova, Berna
    Tiryaki, Fatmanur
    Firat-Karalar, Elif Nur
    Dogan, Buket
    Kiraz, Alper
    [J]. PLOS ONE, 2022, 17 (09):
  • [35] Accelerated radial echo-planar spectroscopic imaging using golden angle view-ordering and compressed-sensing reconstruction with total variation regularization
    Saucedo, Andres
    Macey, Paul M.
    Thomas, M. Albert
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (01) : 46 - 61
  • [36] Three-Dimensional (3D) Image Reconstruction in a Truncated Archimedean-Spiral Scan Geometry Based on the Compressed-Sensing (CS) Theory: Simulation Study
    Hong, Daeki
    Cho, Heemoon
    Cho, Hyosung
    Choi, Sungil
    Je, Uikyu
    Park, Yeonok
    Park, Chulkyu
    Um, Hyunwoo
    Kim, Kyuseok
    Park, Soyoung
    Woo, Taeho
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (08) : 1952 - 1957
  • [37] A Fourier-based compressed sensing technique for accelerated CT image reconstruction using first-order methods
    Choi, Kihwan
    Li, Ruijiang
    Nam, Haewon
    Xing, Lei
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (12): : 3097 - 3119
  • [38] Ultra-High Resolution Photon-Counting Detector CT Reconstruction using Spectral Prior Image Constrained Compressed-Sensing (UHR-SPICCS)
    Rajendran, Kishore
    Tao, Shengzhen
    Abdurakhimova, Dilbar
    Leng, Shuai
    McCollough, Cynthia
    [J]. MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [39] Compressed-sensing (CS)-based 3D image reconstruction in cone-beam CT (CBCT) for low-dose, high-quality dental X-ray imaging
    M. S. Lee
    H. J. Kim
    H. S. Cho
    D. K. Hong
    U. K. Je
    J. E. Oh
    Y. O. Park
    S. H. Lee
    H. M. Cho
    S. I. Choi
    Y. S. Koo
    [J]. Journal of the Korean Physical Society, 2013, 63 : 1066 - 1071
  • [40] Compressed-sensing (CS)-based 3D image reconstruction in cone-beam CT (CBCT) for low-dose, high-quality dental X-ray imaging
    Lee, M. S.
    Kim, H. J.
    Cho, H. S.
    Hong, D. K.
    Je, U. K.
    Oh, J. E.
    Park, Y. O.
    Lee, S. H.
    Cho, H. M.
    Choi, S. I.
    Koo, Y. S.
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (05) : 1066 - 1071