Experimental study on the application of a compressed-sensing (CS) algorithm to dental cone-beam CT (CBCT) for accurate, low-dose image reconstruction

被引:3
|
作者
Oh, Jieun [1 ]
Cho, Hyosung
Je, Uikyu
Lee, Minsik
Kim, Hyojeong
Hong, Daeki
Park, Yeonok
Lee, Seonhwa
Cho, Heemoon
Choi, Sungil
Koo, Yangseo
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju 220710, South Korea
关键词
Compressed-sensing; Computed tomography; Low dose; Image reconstruction; CIRCULAR TRAJECTORIES; COMPUTED-TOMOGRAPHY;
D O I
10.3938/jkps.62.834
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In practical applications of three-dimensional (3D) tomographic imaging, there are often challenges for image reconstruction from insufficient data. In computed tomography (CT); for example, image reconstruction from few views would enable fast scanning with reduced doses to the patient. In this study, we investigated and implemented an efficient reconstruction method based on a compressed-sensing (CS) algorithm, which exploits the sparseness of the gradient image with substantially high accuracy, for accurate, low-dose dental cone-beam CT (CBCT) reconstruction. We applied the algorithm to a commercially-available dental CBCT system (Expert7 (TM), Vatech Co., Korea) and performed experimental works to demonstrate the algorithm for image reconstruction in insufficient sampling problems. We successfully reconstructed CBCT images from several undersampled data and evaluated the reconstruction quality in terms of the universal-quality index (UQI). Experimental demonstrations of the CS-based reconstruction algorithm appear to show that it can be applied to current dental CBCT systems for reducing imaging doses and improving the image quality.
引用
收藏
页码:834 / 838
页数:5
相关论文
共 50 条
  • [1] Experimental study on the application of a compressed-sensing (CS) algorithm to dental cone-beam CT (CBCT) for accurate, low-dose image reconstruction
    Jieun Oh
    Hyosung Cho
    Uikyu Je
    Minsik Lee
    Hyojeong Kim
    Daeki Hong
    Yeonok Park
    Seonhwa Lee
    Heemoon Cho
    Sungil Choi
    Yangseo Koo
    [J]. Journal of the Korean Physical Society, 2013, 62 : 834 - 838
  • [2] Compressed-sensing (CS)-based 3D image reconstruction in cone-beam CT (CBCT) for low-dose, high-quality dental X-ray imaging
    M. S. Lee
    H. J. Kim
    H. S. Cho
    D. K. Hong
    U. K. Je
    J. E. Oh
    Y. O. Park
    S. H. Lee
    H. M. Cho
    S. I. Choi
    Y. S. Koo
    [J]. Journal of the Korean Physical Society, 2013, 63 : 1066 - 1071
  • [3] Compressed-sensing (CS)-based 3D image reconstruction in cone-beam CT (CBCT) for low-dose, high-quality dental X-ray imaging
    Lee, M. S.
    Kim, H. J.
    Cho, H. S.
    Hong, D. K.
    Je, U. K.
    Oh, J. E.
    Park, Y. O.
    Lee, S. H.
    Cho, H. M.
    Choi, S. I.
    Koo, Y. S.
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (05) : 1066 - 1071
  • [4] Compressed Sensing with a First-Order Method for Low-Dose Cone-Beam CT Reconstruction
    Choi, K.
    Wang, J.
    Zhu, L.
    Suh, T.
    Boyd, S.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3442 - +
  • [5] Dental cone-beam CT reconstruction from limited-angle view data based on compressed-sensing (CS) theory for fast, low-dose X-ray imaging
    Je, Uikyu
    Cho, Hyosung
    Lee, Minsik
    Oh, Jieun
    Park, Yeonok
    Hong, Daeki
    Park, Cheulkyu
    Cho, Heemoon
    Choi, Sungil
    Koo, Yangseo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (12) : 1907 - 1911
  • [6] Dental cone-beam CT reconstruction from limited-angle view data based on compressed-sensing (CS) theory for fast, low-dose X-ray imaging
    Uikyu Je
    Hyosung Cho
    Minsik Lee
    Jieun Oh
    Yeonok Park
    Daeki Hong
    Cheulkyu Park
    Heemoon Cho
    Sungil Choi
    Yangseo Koo
    [J]. Journal of the Korean Physical Society, 2014, 64 : 1907 - 1911
  • [7] Image Quality Evaluation of a Compressed-Sensing Algorithm for Image Reconstruction in Dedicated Cone-Beam Breast CT Using Offset-Detector
    Vedantham, S.
    Tseng, H.
    Karellas, A.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [8] A Compressed-Sensing Based Blind Deconvolution Method for Image Deblurring in Dental Cone-Beam Computed Tomography
    Kim, K. S.
    Kang, S. Y.
    Park, C. K.
    Kim, G. A.
    Park, S. Y.
    Cho, Hyosung
    Seo, C. W.
    Lee, D. Y.
    Lim, H. W.
    Lee, H. W.
    Park, J. E.
    Woo, T. H.
    Oh, J. E.
    [J]. JOURNAL OF DIGITAL IMAGING, 2019, 32 (03) : 478 - 488
  • [9] A Compressed-Sensing Based Blind Deconvolution Method for Image Deblurring in Dental Cone-Beam Computed Tomography
    K. S. Kim
    S. Y. Kang
    C. K. Park
    G. A. Kim
    S. Y. Park
    Hyosung Cho
    C. W. Seo
    D. Y. Lee
    H. W. Lim
    H. W. Lee
    J. E. Park
    T. H. Woo
    J. E. Oh
    [J]. Journal of Digital Imaging, 2019, 32 : 478 - 488
  • [10] Compressed Sensing for Low-dose 4D CBCT Image Reconstruction
    Choi, K.
    Li, T.
    Suh, T.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S43 - S44