Image quality and radiation exposure in 320-row temporal bone computed tomography

被引:19
|
作者
Bauknecht, H. C. [1 ]
Siebert, E. [1 ]
Dannenberg, A. [1 ]
Bohner, G. [1 ]
Jach, C. [1 ]
Diekmann, S. [1 ]
Scheurig, C. [2 ]
Klingebiel, R. [1 ]
机构
[1] Univ Med, Charite, Dept Neuroradiol, Berlin, Germany
[2] Univ Med, Charite, Dept Radiol, Berlin, Germany
关键词
cone beam computed tomography; tomography; X-ray computed; temporal bone; petrous bone; radiation dosage; HIGH-DENSITY STRUCTURES; CT SCANNER;
D O I
10.1259/dmfr/14139527
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim was to define image quality and radiation exposure in the recently introduced 320-row CT of the temporal bone (tb) in comparison to a 16-row tb CT. Methods: A cadaveric head phantom was used for repeated tb volume CT studies (80120 kV, 25-150 mAs), performed in a 320-row scanner (single rotation, 0.5 mm slice thickness, kernel FC 51) in comparison to 16-row helical CT using standard acquisition parameters (SAP) of 120 kV and 75 mAs (kernel FC 53). Qualitative image evaluation was performed by two radiologists using a 5-point visual analogue scale. Image noise (D(SD)) was determined by region of interest (ROI) based measurements in cadaveric as well as water phantom studies. Dosimetric measurements of the effective dose (ED) and organ dose (OD) of the lens were performed. Results: Image quality of 320-row tb CT was equivalent to 16-row CT for SAP scans, resulting in image noise levels (D(SD) 16-/320-row) of 109/237 and 206/446 for air and bone respectively. D(SD) differences were predominantly (>90%) attributable to the different kernels available for tb studies in 16- and 320-row CT. Radiation exposure for 16-/320-row SAP scans amounted to 0.36/0.30 mSv (ED) and 10.0/8.4 mGy (lens dose). Conclusion: 320-row volume acquisition in tb CT delivers equivalent image quality to 16-row CT while decreasing radiation exposure figures by one sixth. Image noise increase in 320-row CT is negligible with respect to image quality. Dentomaxillofacial Radiology (2010) 39, 199-206. doi: 10.1259/dmfr/14139527
引用
收藏
页码:199 / 206
页数:8
相关论文
共 50 条
  • [21] Absorbed Radiation Dose in Radiosensitive Organs Using 64- and 320-Row Multidetector Computed Tomography: A Comparative Study
    Khan, Atif N.
    Shuaib, Waqas
    Nikolic, Boris
    Khan, Mohammad K.
    Kang, Jian
    Khosa, Faisal
    SCIENTIFICA, 2014, 2014
  • [22] Whole-Heart 320-Row Computed Tomography: Reduction of Radiation Dose via Prior Coronary Calcium Scanning
    Zimmermann, E.
    Dewey, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (01): : 54 - 59
  • [23] DIAGNOSTIC ACCURACY OF 64-ROW AND 320-ROW MULTIDETECTOR COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY IN DIALYSIS PATIENTS
    Shinohara, Masaya
    Jiro, Aoki
    Tatsuyuki, Sato
    Kentaro, Yasuhara
    Nahoko, Kato
    Koichi, Furui
    Yu, Horiuchi
    Mika, Watanabe
    Masahiko, Asami
    Tanimoto, Shuzou
    Kazuhiro, Hara
    Tanabe, Kengo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1132 - A1132
  • [24] Usefulness of 320-row area detector computed tomography for the diagnosis of congenital absence of portal vein
    Pan, Yuning
    Ren, Dawei
    Jiang, Maoqing
    Huang, Qiuli
    Li, Aijing
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (02): : 4790 - 4795
  • [25] Comparison of echocardiography and 320-row multidetector computed tomography for the diagnosis of congenital heart disease in children
    Ozturk, Erkut
    Tanidir, Ibrahim Cansaran
    Kamali, Hacer
    Ayyildiz, Pelin
    Topel, Cagdas
    Onan, Ismihan Selen
    Turkvatan, Aysel
    Haydin, Sertac
    Guzeltas, Alper
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2021, 40 (08) : 583 - 590
  • [26] Evaluation of appropriateness of second-generation 320-row computed tomography for coronary artery disease
    Utsunomiya, Daisuke
    Oda, Seitaro
    Yuki, Hideaki
    Yamamuro, Megumi
    Tsujita, Kenichi
    Funama, Yoshinori
    Yoshida, Morikatsu
    Kidoh, Masafumi
    Ogawa, Hisao
    Yamashita, Yasuyuki
    SPRINGERPLUS, 2015, 4 : 1 - 6
  • [27] Subtracted Computed Tomography Angiography in the Evaluation of Coronary Arteries With Severe Calcification or Stents Using a 320-Row Computed Tomography Scanner
    Chen, Chun-Chi
    Wu, Patricia Wanping
    Tsay, Pei-Kwei
    Wang, Chun-Chieh
    Toh, Cheng-Hong
    Wan, Yung-Liang
    JOURNAL OF THORACIC IMAGING, 2020, 35 (05) : 317 - 325
  • [28] 320-row CT scanning: reduction in tube current parallels reduction in radiation exposure?
    van der Wall, E. E.
    van Velzen, J. E.
    de Graaf, F. R.
    Jukema, J. W.
    Schuijf, J. D.
    Bax, J. J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (01): : 193 - 197
  • [29] 320-row CT scanning: reduction in tube current parallels reduction in radiation exposure?
    E. E. van der Wall
    J. E. van Velzen
    F. R. de Graaf
    J. W. Jukema
    J. D. Schuijf
    J. J. Bax
    The International Journal of Cardiovascular Imaging, 2012, 28 : 193 - 197
  • [30] TRICUSPID VALVE REMODELING IN FUNCTIONAL TRICUSPID REGURGITATION: 320-ROW MULTI-DETECTOR ROW COMPUTED TOMOGRAPHY INSIGHTS
    Van Rosendael, Philippe
    Joyce, Emer
    Katsanos, Spiros
    Debonnaire, Philippe
    Kamperidis, Vasileios
    Kley, Frank
    Scholte, Arthur
    Schalij, Martin
    Bax, Jeroen
    Marsan, Nina Ajmone
    Delgado, Victoria
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1207 - A1207