Image quality and radiation exposure in 320-row temporal bone computed tomography

被引:19
|
作者
Bauknecht, H. C. [1 ]
Siebert, E. [1 ]
Dannenberg, A. [1 ]
Bohner, G. [1 ]
Jach, C. [1 ]
Diekmann, S. [1 ]
Scheurig, C. [2 ]
Klingebiel, R. [1 ]
机构
[1] Univ Med, Charite, Dept Neuroradiol, Berlin, Germany
[2] Univ Med, Charite, Dept Radiol, Berlin, Germany
关键词
cone beam computed tomography; tomography; X-ray computed; temporal bone; petrous bone; radiation dosage; HIGH-DENSITY STRUCTURES; CT SCANNER;
D O I
10.1259/dmfr/14139527
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim was to define image quality and radiation exposure in the recently introduced 320-row CT of the temporal bone (tb) in comparison to a 16-row tb CT. Methods: A cadaveric head phantom was used for repeated tb volume CT studies (80120 kV, 25-150 mAs), performed in a 320-row scanner (single rotation, 0.5 mm slice thickness, kernel FC 51) in comparison to 16-row helical CT using standard acquisition parameters (SAP) of 120 kV and 75 mAs (kernel FC 53). Qualitative image evaluation was performed by two radiologists using a 5-point visual analogue scale. Image noise (D(SD)) was determined by region of interest (ROI) based measurements in cadaveric as well as water phantom studies. Dosimetric measurements of the effective dose (ED) and organ dose (OD) of the lens were performed. Results: Image quality of 320-row tb CT was equivalent to 16-row CT for SAP scans, resulting in image noise levels (D(SD) 16-/320-row) of 109/237 and 206/446 for air and bone respectively. D(SD) differences were predominantly (>90%) attributable to the different kernels available for tb studies in 16- and 320-row CT. Radiation exposure for 16-/320-row SAP scans amounted to 0.36/0.30 mSv (ED) and 10.0/8.4 mGy (lens dose). Conclusion: 320-row volume acquisition in tb CT delivers equivalent image quality to 16-row CT while decreasing radiation exposure figures by one sixth. Image noise increase in 320-row CT is negligible with respect to image quality. Dentomaxillofacial Radiology (2010) 39, 199-206. doi: 10.1259/dmfr/14139527
引用
收藏
页码:199 / 206
页数:8
相关论文
共 50 条
  • [41] Dynamic enhancement pattern of unstable coronary plaque: analysis by 320-row area detector computed tomography
    Kameyama, T.
    Ihori, H.
    Ohara, K.
    Nonomura, M.
    Misaki, T.
    Inoue, H.
    EUROPEAN HEART JOURNAL, 2015, 36 : 890 - 890
  • [42] The usefulness of low radiation dose subtraction coronary computed tomography angiography for patients with calcification using 320-row area detector CT
    Takamura, Kazuhisa
    Fujimoto, Shinichiro
    Kawaguchi, Yuko
    Kato, Etsuro
    Aoshima, Chihiro
    Hiki, Makoto
    Kumamaru, Kanako K.
    Daida, Hiroyuki
    JOURNAL OF CARDIOLOGY, 2019, 73 (1-2) : 58 - 64
  • [43] Radiation dose optimization in pediatric temporal bone computed tomography: influence of tube tension on image contrast and image quality
    Claude Bertrand Nauer
    Christoph Zubler
    Christian Weisstanner
    Christof Stieger
    Pascal Senn
    Andreas Arnold
    Neuroradiology, 2012, 54 : 247 - 254
  • [44] Radiation dose optimization in pediatric temporal bone computed tomography: influence of tube tension on image contrast and image quality
    Nauer, Claude Bertrand
    Zubler, Christoph
    Weisstanner, Christian
    Stieger, Christof
    Senn, Pascal
    Arnold, Andreas
    NEURORADIOLOGY, 2012, 54 (03) : 247 - 254
  • [45] Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation
    Dewey, Marc
    Zimmermann, Elke
    Deissenrieder, Florian
    Laule, Michael
    Duebel, Hans-Peter
    Schlattmann, Peter
    Knebel, Fabian
    Rutsch, Wolfgang
    Hamm, Bernd
    CIRCULATION, 2009, 120 (10) : 867 - 875
  • [46] Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience
    Neto, Roberto Sasdelli
    Nomura, Cesar Higa
    Sandoval Macedo, Ana Carolina
    Bianco, Danilo Perussi
    Kay, Fernando Uliana
    Szarf, Gilberto
    da Silva Teles, Gustavo Borges
    Shoji, Hamilton
    Santana Netto, Pedro Vieira
    Duarte Passos, Rodrigo Bastos
    Chate, Rodrigo Caruso
    Ishikawa, Walther Yoshiharu
    Bacellar Costa Lima, Joao Paulo
    Rocha, Marcelo Assis
    Marcos, Vinicius Neves
    Failla, Bruna Bonaventura
    de Gusmao Funari, Marcelo Buarque
    EINSTEIN-SAO PAULO, 2013, 11 (03): : 400 - 404
  • [47] Measurement of Pharyngo-laryngeal Volume During Swallowing Using 320-Row Area Detector Computed Tomography
    Iida, Takatoshi
    Kagaya, Hitoshi
    Inamoto, Yoko
    Shibata, Seiko
    Saitoh, Eiichi
    Kanamori, Daisuke
    Hashimoto, Shuji
    Katada, Kazuhiro
    Tohara, Haruka
    Ueda, Koichiro
    DYSPHAGIA, 2017, 32 (06) : 749 - 758
  • [48] Diagnostic Accuracy of 320-Row Multidetector Computed Tomography Coronary Angiography to Noninvasively Assess In-Stent Restenosis
    de Graaf, Fleur R.
    Schuijf, Joanne D.
    van Velzen, Joella E.
    Boogers, Mark J.
    Kroft, Lucia J.
    de Roos, Albert
    Reiber, Johannes H. C.
    Sieders, Allard
    Spano, Fabrizio
    Jukema, J. Wouter
    Schalij, Martin J.
    van der Wall, Ernst E.
    Bax, Jeroen J.
    INVESTIGATIVE RADIOLOGY, 2010, 45 (06) : 331 - 340
  • [49] Measurement of Pharyngo-laryngeal Volume During Swallowing Using 320-Row Area Detector Computed Tomography
    Takatoshi Iida
    Hitoshi Kagaya
    Yoko Inamoto
    Seiko Shibata
    Eiichi Saitoh
    Daisuke Kanamori
    Shuji Hashimoto
    Kazuhiro Katada
    Haruka Tohara
    Koichiro Ueda
    Dysphagia, 2017, 32 : 749 - 758
  • [50] Computed Tomography Myocardial Perfusion Imaging With 320-Row Detector Computed Tomography Accurately Detects Myocardial Ischemia in Patients With Obstructive Coronary Artery Disease
    George, Richard T.
    Arbab-Zadeh, Armin
    Miller, Julie M.
    Vavere, Andrea L.
    Bengel, Frank M.
    Lardo, Albert C.
    Lima, Joao A. C.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (03) : 333 - 340