Subtracted Computed Tomography Angiography in the Evaluation of Coronary Arteries With Severe Calcification or Stents Using a 320-Row Computed Tomography Scanner

被引:8
|
作者
Chen, Chun-Chi [1 ]
Wu, Patricia Wanping [2 ]
Tsay, Pei-Kwei [3 ,4 ]
Wang, Chun-Chieh [1 ]
Toh, Cheng-Hong [2 ]
Wan, Yung-Liang [2 ]
机构
[1] Linkou & Taoyuan Chang Gung Mem Hosp, Sect Cardiol, Dept Internal Med, Taoyuan, Taiwan
[2] Linkou & Taoyuan Chang Gung Mem Hosp, Dept Med Imaging & Intervent, Taoyuan, Taiwan
[3] Chang Gung Univ, Coll Med, Dept Publ Hlth, Taoyuan, Taiwan
[4] Chang Gung Univ, Coll Med, Ctr Biostat, Taoyuan, Taiwan
关键词
coronary artery; stent; calcification; 320-row computed tomography; subtraction computed tomography angiography; CT ANGIOGRAPHY; DIAGNOSTIC PERFORMANCE; METAL SUBTRACTION; CALCIUM; DISEASE; FEASIBILITY; RESTENOSIS; ACCURACY; PROTOCOL;
D O I
10.1097/RTI.0000000000000480
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Coronary computed tomography angiography (CCTA) has its limitations in evaluating arteries with stents or heavy calcification. This study compares the diagnostic performance of subtracted coronary computed tomography angiography (SCCTA) and nonsubtracted coronary computed tomography angiography (NSCCTA) in evaluating coronary artery disease (CAD) and in-stent restenosis (ISR). Materials and Methods: Twelve patients with stents and 20 patients with heavy coronary calcifications (total Agatston's score >400) underwent both SCCTA and invasive coronary angiography (ICA) with an interval of <3 months. Four subjects in the stented group also had heavy calcifications. Overall, 30 stented segments and 202 calcified segments were assessed to compare the diagnostic performance of SCCTA and NSCCTA in detecting ISR and CAD. Results: For the 30 stented segments, SCCTA/NSCCTA had a sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) (shown in %) of 66.7/100, 100/55.6, 96.7/60, 100/20, and 96.4/100 in diagnosing ISR, respectively. For the 202 calcified segments, SCCTA/NSCCTA had a sensitivity, specificity, accuracy, PPV, and NPV of 68.8/84.4, 97.6/76.5, 93.1/77.7, 84.6/40.3, and 94.3/96.3 in diagnosing CAD, respectively. For both stented and calcified segments, SCCTA was significantly superior to NSCCTA in specificity and accuracy. For the calcified segments, SCCTA was significantly superior to NSCCTA in PPV. There was no significant difference in the diagnostic performance of SCCTA between the stented and calcified segments. Conclusions: The diagnostic accuracy and specificity of SCCTA are significantly superior to those of NSCCTA in evaluating CAD and ISR. SCCTA shows no statistical difference in its diagnostic performance between the stented and calcified segments.
引用
收藏
页码:317 / 325
页数:9
相关论文
共 50 条
  • [1] Evaluation of Venous and Arterial Bypass Grafts using 320-row Multidetector Computed Tomography Coronary Angiography
    De Graaf, F. R.
    Schuijf, J. D.
    Veltman, C. E.
    Van Velzen, J. E.
    Kroft, L. J.
    De Roos, A.
    Reiber, J. H. C.
    Jukema, J. W.
    Van Der Wall, E. E.
    Bax, J. J.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A21 - A22
  • [2] Image quality of coronary computed tomography angiography with 320-Row area detector computed tomography in children with congenital heart disease
    Qin, Jie
    Cai, Songwang
    Peng, Lingrong
    Tang, Wenjie
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C142 - C142
  • [3] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Tada, Akihiro
    Sato, Shuhei
    Kanie, Yuichiro
    Tanaka, Takashi
    Inai, Ryota
    Akagi, Noriaki
    Morimitsu, Yusuke
    Kanazawa, Susumu
    PEDIATRIC CARDIOLOGY, 2016, 37 (03) : 497 - 503
  • [4] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Akihiro Tada
    Shuhei Sato
    Yuichiro Kanie
    Takashi Tanaka
    Ryota Inai
    Noriaki Akagi
    Yusuke Morimitsu
    Susumu Kanazawa
    Pediatric Cardiology, 2016, 37 : 497 - 503
  • [5] Prediction of Cerebrovascular Reserve Capacity by Computed Tomography Perfusion Using 320-Row Computed Tomography
    Takahashi, Satoshi
    Tanizaki, Yoshio
    Kimura, Hiroaki
    Akaji, Kazunori
    Kano, Tadashige
    Suzuki, Kentaro
    Takayama, Youhei
    Kanzawa, Takao
    Shidoh, Satoka
    Nakazawa, Masaki
    Yoshida, Kazunari
    Mihara, Ban
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2015, 24 (05): : 939 - 945
  • [6] 320-Row multidetector computed tomography coronary angiography in patients presenting with suspected acute coronary syndrome
    Van Velzen, J. E.
    Schuijf, J. D.
    De Graaf, F. R.
    Kroner, E. S. J.
    Kroft, L. J.
    De Roos, A.
    Schalij, M. J.
    Jukema, J. W.
    Van Der Wall, E. E.
    Bax, J. J.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A22 - A22
  • [7] Coronary artery-to-pulmonary artery fistula in adults: evaluation with 320-row detector computed tomography coronary angiography
    Hang, Kaibing
    Zhao, Guoli
    Su, Weiwei
    Bao, Guangjin
    Zhao, Qi
    Jiao, Zizhen
    Tian, Zhanqi
    Zhang, Hui
    Nie, Lin
    Luo, Rui
    Li, Lifang
    Huang, Min
    Shi, Lijing
    Li, Shuping
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (18)
  • [8] Evaluation of Pharyngoesophageal Segment Using 320-Row Area Detector Computed Tomography
    Wattanapan, Pattra
    Kagaya, Hitoshi
    Inamoto, Yoko
    Saitoh, Eiichi
    Shibata, Seiko
    Iida, Takatoshi
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2018, 127 (12): : 888 - 894
  • [9] The usefulness of low radiation dose subtraction coronary computed tomography angiography for patients with calcification using 320-row area detector CT
    Takamura, Kazuhisa
    Fujimoto, Shinichiro
    Kawaguchi, Yuko
    Kato, Etsuro
    Aoshima, Chihiro
    Hiki, Makoto
    Kumamaru, Kanako K.
    Daida, Hiroyuki
    JOURNAL OF CARDIOLOGY, 2019, 73 (1-2) : 58 - 64
  • [10] Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience
    Neto, Roberto Sasdelli
    Nomura, Cesar Higa
    Sandoval Macedo, Ana Carolina
    Bianco, Danilo Perussi
    Kay, Fernando Uliana
    Szarf, Gilberto
    da Silva Teles, Gustavo Borges
    Shoji, Hamilton
    Santana Netto, Pedro Vieira
    Duarte Passos, Rodrigo Bastos
    Chate, Rodrigo Caruso
    Ishikawa, Walther Yoshiharu
    Bacellar Costa Lima, Joao Paulo
    Rocha, Marcelo Assis
    Marcos, Vinicius Neves
    Failla, Bruna Bonaventura
    de Gusmao Funari, Marcelo Buarque
    EINSTEIN-SAO PAULO, 2013, 11 (03): : 400 - 404