Effects of scatter in dual-source CT

被引:1
|
作者
Kyriakou, Y. [1 ]
Ertel, D. [1 ]
Krause, J. [1 ]
Kalender, W. [1 ]
机构
[1] Inst Med Phys, Erlangen, Germany
关键词
D O I
10.1118/1.2760409
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the magnitude and distribution of scatter for dual‐source CT (DSCT) and its impact on image quality. Materials and Methods: Apart from forward scatter which is given for all CT scanners, the measurements at a dual‐source system is also affected by cross scattered photons from the second tube‐detector system arranged at 90°. Simulations and measurements of homogenous phantoms of increasing diameter (100–400 mm) and of anthropomorphic phantoms were conducted for a DSCT scanner (SOMATOM Definition, Siemens Medical Solutions, Forchheim, Germany). The simulations of both forward and cross scatter were carried out using combined analytical and Monte Carlo simulation methods using a collimation of 19.2 mm for both tube‐detector systems. Measurements of cross scatter were performed by switching one tube off, still reading out the corresponding detector. Cross scatter was evaluated with respect to anthropomorphic and homogeneous phantoms for different imaging conditions such as different tube voltages, bow—tie filters. Dual‐energy scanning was included in the evaluations. Results: The forward scatter fraction increased with increasing diameter to 10% for a PMMA phantom of 400 mm diameter; for cross scatter, the mean intensity was lower or equivalent to forward scatter for small phantoms but was larger for increased phantom diameters. For large objects the ratio of cross scatter intensity to the sum of primary signal and forward scatter intensity reaches values higher than 100%. The outer dimensions of the object appear to be decisive for cross‐scatter whereas the influence of phantom inhomogeneity appears to be negligible. For dual energy — dual source scan modes the tube current setting for each tube should be adapted to achieve a minimization of cross scatter. Conclusion: The cross scatter magnitude is non‐negligible for a DSCT system and a compensation of its contribution is necessary for the assurance of high image quality. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2345 / 2345
页数:1
相关论文
共 50 条
  • [41] Pulmonary Embolism Detection with Dual-Energy CT: Experimental Study of Dual-Source CT in Rabbits
    Zhang, Long-Jiang
    Zhao, Yan-E
    Wu, Sheng-Yong
    Yeh, Benjamin M.
    Zhou, Chang-Sheng
    Hu, Xiao-Bo
    Hu, Qiu-Ju
    Lu, Guang-Ming
    RADIOLOGY, 2009, 252 (01) : 61 - 70
  • [42] Dual-source CT coronary angiography in patients with atrial fibrillation: Comparison with single-source CT
    Wang, Yining
    Zhang, Zhuhua
    Kong, Lingyan
    Song, Lan
    Merges, Reto D.
    Chen, Jiuhong
    Jin, Zhengyu
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : 434 - 441
  • [43] In vivo measurement of iron concentration using dual-source, dual-energy CT
    Weavers, Paul T.
    Jacobsen, Megan
    Liu, Xin
    Morin, Richard L.
    McCollough, Cynthia H.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [44] Pancreatic dual-source dual-energy CT: Is it time to discard unenhanced imaging?
    Mileto, Achille
    Mazziotti, Silvio
    Gaeta, Michele
    Bottari, Antonio
    Zimbaro, Fabrizio
    Giardina, Claudio
    Ascenti, Giorgio
    CLINICAL RADIOLOGY, 2012, 67 (04) : 334 - 339
  • [45] Dual-Source Dual-Energy CT in Submandibular Sialolithiasis: Reliability and Radiation Burden
    Pulickal, Geoiphy George
    Singh, Dinesh
    Lohan, Rahul
    Chawla, Ashish
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (06) : 1291 - 1296
  • [46] Quantitative imaging of chemical composition using dual-energy, dual-source CT
    Liu, Xin
    Primak, Andrew N.
    Yu, Lifeng
    McCollough, Cynthia H.
    Morin, Richard L.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [47] Low kVp imaging for dose reduction in dual-source cardiac CT
    Luaces, Maria
    Akers, Scott
    Litt, Harold
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 165 - 175
  • [48] Temporal resolution and motion artifacts in single-source and dual-source cardiac CT
    Schoendube, Harald
    Allmendinger, Thomas
    Stierstorfer, Karl
    Bruder, Herbert
    Flohr, Thomas
    MEDICAL PHYSICS, 2013, 40 (03)
  • [49] Coronary bifurcation stent morphology in dual-source CT: validation with micro-CT
    Eom, Hye-Joung
    Yang, Dong Hyun
    Kim, Young-Hak
    Roh, Jae-Hyung
    Kweon, Jihoon
    Kang, Soo-Jin
    Kim, Namkug
    Kang, Joon-Won
    Lim, Tae-Hwan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (11): : 1659 - 1665
  • [50] Dual-Source Dual-Energy CT Evaluation of Complex Cystic Renal Masses
    Ascenti, Giorgio
    Mazziotti, Silvio
    Mileto, Achille
    Racchiusa, Sergio
    Donato, Rocco
    Settineri, Nicola
    Gaeta, Michele
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : 1026 - 1034