Effects of scatter in dual-source CT

被引:1
|
作者
Kyriakou, Y. [1 ]
Ertel, D. [1 ]
Krause, J. [1 ]
Kalender, W. [1 ]
机构
[1] Inst Med Phys, Erlangen, Germany
关键词
D O I
10.1118/1.2760409
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the magnitude and distribution of scatter for dual‐source CT (DSCT) and its impact on image quality. Materials and Methods: Apart from forward scatter which is given for all CT scanners, the measurements at a dual‐source system is also affected by cross scattered photons from the second tube‐detector system arranged at 90°. Simulations and measurements of homogenous phantoms of increasing diameter (100–400 mm) and of anthropomorphic phantoms were conducted for a DSCT scanner (SOMATOM Definition, Siemens Medical Solutions, Forchheim, Germany). The simulations of both forward and cross scatter were carried out using combined analytical and Monte Carlo simulation methods using a collimation of 19.2 mm for both tube‐detector systems. Measurements of cross scatter were performed by switching one tube off, still reading out the corresponding detector. Cross scatter was evaluated with respect to anthropomorphic and homogeneous phantoms for different imaging conditions such as different tube voltages, bow—tie filters. Dual‐energy scanning was included in the evaluations. Results: The forward scatter fraction increased with increasing diameter to 10% for a PMMA phantom of 400 mm diameter; for cross scatter, the mean intensity was lower or equivalent to forward scatter for small phantoms but was larger for increased phantom diameters. For large objects the ratio of cross scatter intensity to the sum of primary signal and forward scatter intensity reaches values higher than 100%. The outer dimensions of the object appear to be decisive for cross‐scatter whereas the influence of phantom inhomogeneity appears to be negligible. For dual energy — dual source scan modes the tube current setting for each tube should be adapted to achieve a minimization of cross scatter. Conclusion: The cross scatter magnitude is non‐negligible for a DSCT system and a compensation of its contribution is necessary for the assurance of high image quality. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2345 / 2345
页数:1
相关论文
共 50 条
  • [31] Multi-slice and Dual-source CT in Cardiac Imaging
    Thali, M.
    KARDIOLOGE, 2008, 2 (04): : 293 - 293
  • [32] Is dual-source CT coronary angiography ready for the real world?
    Cademartiri, Filippo
    Maffei, Erica
    Mollet, Nico R.
    EUROPEAN HEART JOURNAL, 2008, 29 (06) : 701 - 703
  • [33] Dual-Source CT: In Vitro Characterization of Gallstones using Dual Energy Analysis
    Voit, H.
    Krauss, B.
    Heinrich, M. C.
    Dimmler, A.
    Adamitz, B.
    Hinkmann, F. M.
    Uder, M.
    Kuettner, A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (04): : 367 - 373
  • [34] First performance evaluation of a dual-source CT (DSCT) system
    Flohr, TG
    McCollough, CH
    Bruder, H
    Petersilka, M
    Gruber, K
    Süss, C
    Grasruck, M
    Stierstorfer, K
    Krauss, B
    Raupach, R
    Primak, AN
    Küttner, A
    Achenbach, S
    Becker, C
    Kopp, A
    Ohnesorge, BM
    EUROPEAN RADIOLOGY, 2006, 16 (02) : 256 - 268
  • [35] First performance evaluation of a dual-source CT (DSCT) system
    Thomas G. Flohr
    Cynthia H. McCollough
    Herbert Bruder
    Martin Petersilka
    Klaus Gruber
    Christoph Süβ
    Michael Grasruck
    Karl Stierstorfer
    Bernhard Krauss
    Rainer Raupach
    Andrew N. Primak
    Axel Küttner
    Stefan Achenbach
    Christoph Becker
    Andreas Kopp
    Bernd M. Ohnesorge
    European Radiology, 2006, 16 : 256 - 268
  • [36] Left Ventricular Diastolic Dysfunction Assessment with Dual-Source CT
    Wen, Zhaoying
    Ma, Heng
    Zhao, Ying
    Fan, Zhanming
    Zhang, Zhaoqi
    Choi, Sang Il
    Choe, Yeon Hyeon
    Liu, Jiayi
    PLOS ONE, 2015, 10 (05):
  • [37] Dual-Source CT Images of a Thrombosed Mechanical Mitral Prosthesis
    Kepka, Cezary
    Opolski, Maksymilian P.
    Lichomski, Jerzy
    Stoklosa, Patrycjusz
    JOURNAL OF CARDIAC SURGERY, 2011, 26 (03) : 300 - 301
  • [38] Low dose dual-source CT angiography of the thoracic aorta
    Cormac Farrelly
    Amir Davarpanah
    Aoife N. Keeling
    John Sheehan
    Ann Ragin
    Vahid Yaghmai
    James C. Carr
    The International Journal of Cardiovascular Imaging, 2011, 27 : 1025 - 1034
  • [39] Dual-source, dual-energy multidetector CT for the evaluation of pancreatic tumours
    Chu, A. J.
    Lee, J. M.
    Lee, Y. J.
    Moon, S. K.
    Han, J. K.
    Choi, B. I.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018): : E891 - E898
  • [40] Performance evaluation for new-technology CT systems: Dual-source CT
    McCollough, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2509 - 2510