Dual-source CT coronary angiography in patients with atrial fibrillation: Comparison with single-source CT

被引:31
|
作者
Wang, Yining [1 ]
Zhang, Zhuhua [1 ]
Kong, Lingyan [1 ]
Song, Lan [1 ]
Merges, Reto D.
Chen, Jiuhong
Jin, Zhengyu [1 ]
机构
[1] Chinese Acad Med Sci, Dept Radiol, Peking Union Med Coll Hosp, Beijing 100730, Peoples R China
关键词
Atrial fibrillation; Tomography; X-ray computed; Coronary angiography;
D O I
10.1016/j.ejrad.2008.09.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the performance of dual-source computed tomography (DSCT) for the visualization of the coronary arteries in a population with atrial fibrillation (AF) compared to single-source CT (SSCT) and to explore the impact of patients' heart rate (HR) on image quality (IQ) and reconstruction timing. Methods: Thirty consecutive patients (11 male, 19 female; 69.0 +/- 9.2 years old) with suspected coronary artery disease and permanent AF were examined on a DSCT scanner (120 kV, 400 mAs/rot, 0.33 s rotation time, 64x0.6 mm collimation, pitch 0.20-0.28, Siemens Somatom Definition). Patients were divided into two groups: low and medium HR group (HR <= 80 bpm, n = 14) and high HR group (HR > 80 bpm, n = 16). Five of the patients also underwent conventional coronary angiography (CAG). The raw data from both tube detector arrays were reconstructed as DSCT data using a routine algorithm (temporal resolution of 83 ms). The raw data from one tube detector array was reconstructed separately on the same system using a routine single source algorithm (temporal resolution of 83-165 ms) and defined as virtual SSCT data. Image quality was assessed using a four-point grading scale from excellent (1) to non-assessable (4). Results: IQ of the DSCT data was significantly better than that of the virtual SSCT data (mean score 1.33 +/- 0.61 vs. 1.80 +/- 1.02; Z=-8.755, P = 0.000). 98.6% of the segments shown in DSCT were diagnostic, compared with 89.9% of the segments in virtual SSCT, chi(2) = 32.595, P = 0.000. In DSCT group, IQ of low HR group was also better than that of high HR group, although the difference was not as big (mean score 1.25 +/- 0.52 vs. 1.38 +/- 0.66; Z=-2.227, P = 0.026). The mean HR of low HR group and high HR group were 67.4 +/- 8.5 beats per minute (bpm) and 94.2 +/- 8.8 bpm (t=-8.499, P = 0.000). The range of the variation of HR was higher in high HR group than in low HR group (mean difference between maximum and minimum HR 79.5 +/- 21.0 vs. 49.9 +/- 21.1 bpm; t=-3.845, P = 0.001). In 23 (77%) patients optimal IQ was achieved within one phase for all three main arteries. In low HR group, the optimal phase was distributed evenly between diastole and systole; but in high HR group, the optimal phase shifted to systole in most cases (92%). In five cases these results were compared to CAG results to look for the ability to identify stenosis with a diameter reduction of more than 50% of the lumen. With DSCT it was possible to diagnose 20 of 21 stenosis and 48 of 49 non-stenosed vessel segments correctly. With SSCT 19 of 21 stenosis and 45 of 49 non-stenosed vessel segments were diagnosed correctly according to CAG. Due to its high temporal resolution, DSCT provides images of full diagnostic image quality in patients with AF, which otherwise would be excluded from CT examinations. The number of assessable segments for DSCT is still somewhat less than in non-AF patients, but in opposition to SSCT still valid for routine diagnostic imaging. Patients' HR had impact on IQ and reconstruction timing. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:434 / 441
页数:8
相关论文
共 50 条
  • [1] Accuracy of dual-source CT to identify coronary artery stenoses in patients with atrial fibrillation: comparison with invasive coronary angiography
    Marwan, M.
    Schepis, T.
    Renz, A.
    Pflederer, T.
    Ropers, D.
    Daniel, W. G.
    Achenbach, S.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 : 205 - 205
  • [2] Diagnostic accuracy of dual-source CT coronary angiography in patients with atrial fibrillation: Meta analysis
    Sun, Gang
    Li, Min
    Jiang, Zhi-wei
    Xu, Lin
    Peng, Zhao-hui
    Ding, Juan
    Li, Li
    Jin, Zhi-tao
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (10) : 1749 - 1754
  • [3] Dual-Source Versus Single-Source Cardiac CT Angiography: Comparison of Diagnostic Image Quality
    Donnino, Robert
    Jacobs, Jill E.
    Doshi, Jay V.
    Hecht, Elizabeth M.
    Kim, Danny C.
    Babb, James S.
    Srichai, Monvadi B.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) : 1051 - 1056
  • [4] Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography
    Zhang, Jian-Jun
    Liu, Tie
    Feng, Yue
    Wu, Wei-Feng
    Mou, Cai-Yun
    Zhai, Li-Hao
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2011, 12 (04) : 416 - 423
  • [5] Radiation Dose at Coronary CT Angiography: Second-Generation Dual-Source CT Versus Single-Source 64-MDCT and First-Generation Dual-Source CT
    Fink, Christian
    Krissak, Radko
    Henzler, Thomas
    Lechel, Ursula
    Brix, Gunnar
    Takx, Richard A. P.
    Nance, John W.
    Abro, Joseph A.
    Schoenberg, Stefan O.
    Schoepf, U. Joseph
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (05) : W550 - W557
  • [6] Effectiveness of dual-source CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: Initial experience
    Oncel, Dilek
    Oncel, Guray
    Tastan, Ahmet
    [J]. RADIOLOGY, 2007, 245 (03) : 703 - 711
  • [7] Dual-source CT versus single-source 64-section CT angiography for coronary artery disease: A meta-analysis
    Jiang, B.
    Wang, J.
    Lv, X.
    Cai, W.
    [J]. CLINICAL RADIOLOGY, 2014, 69 (08) : 861 - 869
  • [8] Comparison of myocardial bridging by dual-source CT with conventional coronary angiography
    Lu, Guang-Ming
    Zhang, Long-Jiang
    Guo, Hua
    Huang, Wei
    Merges, Reto D.
    [J]. CIRCULATION JOURNAL, 2008, 72 (07) : 1079 - 1085
  • [9] Prospectively ECG-triggered sequential dual-source coronary CT angiography in patients with atrial fibrillation: comparison with retrospectively ECG-gated helical CT
    Xu, Lei
    Yang, Lin
    Zhang, Zhaoqi
    Wang, Yining
    Jin, Zhengyu
    Zhang, Longjiang
    Lu, Guangming
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (07) : 1822 - 1828
  • [10] Prospectively ECG-triggered sequential dual-source coronary CT angiography in patients with atrial fibrillation: comparison with retrospectively ECG-gated helical CT
    Lei Xu
    Lin Yang
    Zhaoqi Zhang
    Yining Wang
    Zhengyu Jin
    Longjiang Zhang
    Guangming Lu
    [J]. European Radiology, 2013, 23 : 1822 - 1828