Noninvasive cardiac output monitoring (NICOM): a clinical validation

被引:235
|
作者
Squara, Pierre [1 ]
Denjean, Dominique [1 ]
Estagnasie, Philippe [1 ]
Brusset, Alain [1 ]
Dib, Jean Claude [1 ]
Dubois, Claude [1 ]
机构
[1] CERIC, Clin Ambroise Pare, F-92200 Neuilly Sur Seine, France
关键词
D O I
10.1007/s00134-007-0640-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the clinical utility of a new device for continuous noninvasive cardiac output monitoring (NICOM) based on chest bio-reactance compared with cardiac output measured semi-continuously by thermodilution using a pulmonary artery catheter (PAC-CCO). Design: Prospective, single-center study. Setting: Intensive care unit. Patients: Consecutive adult patients immediately after cardiac surgery. Interventions: Cardiac output measurements obtained from NICOM and thermodilution were simultaneously recorded minute by minute and compared in 110 patients. We evaluated the accuracy, precision, responsiveness, and reliability of NICOM for detecting cardiac output changes. Tolerance for each of these parameters was specified prospectively. Measurements and results: A total of 65,888 pairs of cardiac output measurements were collected. Mean reference values for cardiac output ranged from 2.79 to 9.271/min. During periods of stable PAC-CCO (slope < +/- 10%, 2SD/mean < 20%), the correlation between NICOM and thermodilution was R=0.82; bias was +0.16 +/- 0.521/min (+4.0 +/- 11.3%), and relative error was 9.1%+/- 7.8%. In 85% of patients the relative error was < 20%. During periods of increasing output, slopes were similar with the two methods in 96% of patients and intra-class correlation was positive in 96%. Corresponding values during periods of decreasing output were 90% and 84%, respectively. Precision was always better with NICOM than with thermodilution. During hemodynamic challenges, changes were 3.1 +/- 3.8min faster with NICOM (p < 0.01) and amplitude of changes did not differ significantly. Finally, sensitivity of the NICOM for detecting significant directional changes was 93% and specificity was 93%. Conclusion:Cardiac output measured by NICOM had most often acceptable accuracy, precision, and responsiveness in a wide range of circulatory situations.
引用
收藏
页码:1191 / 1194
页数:4
相关论文
共 50 条
  • [21] Noninvasive Cardiac Output Monitoring System Based on Photoplethysmography
    Wang, Can
    Huang, Chao
    Ye, Shuming
    PROCEEDINGS OF 2014 IEEE INTERNATIONAL CONFERENCE ON PROGRESS IN INFORMATICS AND COMPUTING (PIC), 2014, : 669 - 673
  • [22] Noninvasive cardiac output monitoring in the pediatric cardiac intensive care unit
    Absi, Mohammed Ali
    Lutterman, Joel
    Wetzel, Glenn T.
    CURRENT OPINION IN CARDIOLOGY, 2010, 25 (02) : 77 - 79
  • [23] Better Thanthermodiluation: Validation of Foreign Gas Rebreathing for Noninvasive Measurement of Cardiac Output in Clinical Practice
    Stoller, Douglas
    Sarma, Satyam
    Lawley, Justin
    Howden, Erin
    Levine, Benjamin D.
    JOURNAL OF CARDIAC FAILURE, 2016, 22 (08) : S17 - S17
  • [24] Validation of Noninvasive Measurements of Cardiac Output in Mice Using Echocardiography
    Tournoux, Francois
    Petersen, Bodil
    Thibault, Helene
    Zou, Lin
    Raher, Michael J.
    Kurtz, Baptiste
    Halpern, Elkan F.
    Chaput, Miguel
    Chao, Wei
    Picard, Michael H.
    Scherrer-Crosbie, Marielle
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (04) : 465 - 470
  • [25] 216 Cardiac Output Monitoring in Children by Bioreactance; a New Method for Noninvasive Cardiac Output Measurement
    Y B Diez
    J U Villaescusa
    M J S García
    M B Prieto
    J L -H Cid
    A Laborda
    Pediatric Research, 2010, 68 : 113 - 113
  • [26] Clinical evaluation of a noninvasive method to measure cardiac output
    J Reutershan
    T Kapp
    R Fretschner
    Critical Care, 5 (Suppl 1):
  • [27] Clinical evaluation of a noninvasive method to measure cardiac output
    Reutershan, J
    Kapp, T
    Unertl, K
    Fretschner, R
    ANAESTHESIST, 2003, 52 (09): : 778 - 786
  • [28] Noninvasive Cardiac Output Determination: Broadening the Applicability of Hemodynamic Monitoring
    Compton, Friederike
    Schaefer, Juergen-Heiner
    SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2009, 13 (01) : 44 - 55
  • [29] Noninvasive monitoring of cardiac output during exercise by inductance cardiography
    Kaplan, V
    Bucklar, GB
    Bloch, KE
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (05): : 747 - 752
  • [30] Reference values for noninvasive cardiac output monitoring in children Reply
    Cattermole, Giles N.
    Graham, Colin A.
    Rainer, Timothy H.
    CRITICAL CARE MEDICINE, 2011, 39 (01) : 227 - 228