Noninvasive cardiac output monitoring (NICOM): a clinical validation

被引:235
|
作者
Squara, Pierre [1 ]
Denjean, Dominique [1 ]
Estagnasie, Philippe [1 ]
Brusset, Alain [1 ]
Dib, Jean Claude [1 ]
Dubois, Claude [1 ]
机构
[1] CERIC, Clin Ambroise Pare, F-92200 Neuilly Sur Seine, France
关键词
D O I
10.1007/s00134-007-0640-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the clinical utility of a new device for continuous noninvasive cardiac output monitoring (NICOM) based on chest bio-reactance compared with cardiac output measured semi-continuously by thermodilution using a pulmonary artery catheter (PAC-CCO). Design: Prospective, single-center study. Setting: Intensive care unit. Patients: Consecutive adult patients immediately after cardiac surgery. Interventions: Cardiac output measurements obtained from NICOM and thermodilution were simultaneously recorded minute by minute and compared in 110 patients. We evaluated the accuracy, precision, responsiveness, and reliability of NICOM for detecting cardiac output changes. Tolerance for each of these parameters was specified prospectively. Measurements and results: A total of 65,888 pairs of cardiac output measurements were collected. Mean reference values for cardiac output ranged from 2.79 to 9.271/min. During periods of stable PAC-CCO (slope < +/- 10%, 2SD/mean < 20%), the correlation between NICOM and thermodilution was R=0.82; bias was +0.16 +/- 0.521/min (+4.0 +/- 11.3%), and relative error was 9.1%+/- 7.8%. In 85% of patients the relative error was < 20%. During periods of increasing output, slopes were similar with the two methods in 96% of patients and intra-class correlation was positive in 96%. Corresponding values during periods of decreasing output were 90% and 84%, respectively. Precision was always better with NICOM than with thermodilution. During hemodynamic challenges, changes were 3.1 +/- 3.8min faster with NICOM (p < 0.01) and amplitude of changes did not differ significantly. Finally, sensitivity of the NICOM for detecting significant directional changes was 93% and specificity was 93%. Conclusion:Cardiac output measured by NICOM had most often acceptable accuracy, precision, and responsiveness in a wide range of circulatory situations.
引用
收藏
页码:1191 / 1194
页数:4
相关论文
共 50 条
  • [41] Accuracy assessment of noninvasive cardiac output monitoring in the hemodynamic monitoring in critically ill patients
    Zhu, Guijun
    Zhang, Kun
    Fu, Yuxin
    Hu, Zhenjie
    ANNALS OF PALLIATIVE MEDICINE, 2020, 9 (05) : 3506 - 3512
  • [42] Noninvasive Cardiac Output Monitoring in Newborn with Hypoplastic Left Heart Syndrome
    Gatelli, Italo Francesco
    Vitelli, Ottavio
    Chiesa, Gaia
    De Rienzo, Francesca
    Martinelli, Stefano
    AMERICAN JOURNAL OF PERINATOLOGY, 2020, 37 : S54 - S56
  • [43] Responsiveness of Noninvasive Continuous Cardiac Output Monitoring During the Valsalva Maneuver
    Delaney, L. J.
    Bellomo, R.
    van Haren, F.
    CLINICAL NURSING RESEARCH, 2020, 29 (02) : 127 - 132
  • [44] Non- invasive cardiac output monitoring (NICOM) - a novel technique for measurement of cardiovascular status in healthy nulliparous pregnancy
    Monteith, C.
    McSweeney, L.
    Shirren, L.
    Doherty, A.
    Breathnach, C. R.
    Tully, E. C.
    Dicker, P.
    Malone, F. D.
    EL-Khuffash, A.
    Kent, E.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 115 - 115
  • [46] Development and validation of a noninvasive method to estimate cardiac output using cuff sphygmomanometry
    Chid, Shiu-Shin
    Tsai, Jeffrey J.
    Hsu, Yen-Ming
    Lapointe, Jeffrey C.
    Huynh-Covey, Thao
    Kwan, Oi Ling B.
    DeMaria, Anthony N.
    CLINICAL CARDIOLOGY, 2007, 30 (12) : 615 - 620
  • [47] DOES NON-INVASIVE CARDIAC OUTPUT MONITORING (NICOM) CORRELATE WITH STANDARD INVASIVE HEMODYNAMIC MONITORING IN PATIENTS WITH ACUTE DECOMPENSATED HEART FAILURE?
    Rali, Aniket
    Buechler, Tyler
    Van-Gotten, Bridget
    Burgen, Emily
    Chen, John
    Shah, Zubair
    Haglund, Nicholas
    Sauer, Andrew
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 819 - 819
  • [48] Clinical validation of bioreactance for the measurement of cardiac output in pregnancy
    Ling, H. Z.
    Gallardo-Arozena, M.
    Company-Calabuig, A. M.
    Nicolaides, K. H.
    Kametas, N. A.
    ANAESTHESIA, 2020, 75 (10) : 1307 - 1313
  • [49] NONINVASIVE CARDIAC MONITORING
    DENNIS, JW
    GREISLER, HP
    NURSING CLINICS OF NORTH AMERICA, 1987, 22 (01) : 111 - 120
  • [50] NONINVASIVE CARDIAC MONITORING
    CLEMENTS, FM
    DEBRUIJN, NP
    CRITICAL CARE CLINICS, 1988, 4 (03) : 435 - 454