Noninvasive cardiac output monitoring (NICOM): a clinical validation

被引:235
|
作者
Squara, Pierre [1 ]
Denjean, Dominique [1 ]
Estagnasie, Philippe [1 ]
Brusset, Alain [1 ]
Dib, Jean Claude [1 ]
Dubois, Claude [1 ]
机构
[1] CERIC, Clin Ambroise Pare, F-92200 Neuilly Sur Seine, France
关键词
D O I
10.1007/s00134-007-0640-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the clinical utility of a new device for continuous noninvasive cardiac output monitoring (NICOM) based on chest bio-reactance compared with cardiac output measured semi-continuously by thermodilution using a pulmonary artery catheter (PAC-CCO). Design: Prospective, single-center study. Setting: Intensive care unit. Patients: Consecutive adult patients immediately after cardiac surgery. Interventions: Cardiac output measurements obtained from NICOM and thermodilution were simultaneously recorded minute by minute and compared in 110 patients. We evaluated the accuracy, precision, responsiveness, and reliability of NICOM for detecting cardiac output changes. Tolerance for each of these parameters was specified prospectively. Measurements and results: A total of 65,888 pairs of cardiac output measurements were collected. Mean reference values for cardiac output ranged from 2.79 to 9.271/min. During periods of stable PAC-CCO (slope < +/- 10%, 2SD/mean < 20%), the correlation between NICOM and thermodilution was R=0.82; bias was +0.16 +/- 0.521/min (+4.0 +/- 11.3%), and relative error was 9.1%+/- 7.8%. In 85% of patients the relative error was < 20%. During periods of increasing output, slopes were similar with the two methods in 96% of patients and intra-class correlation was positive in 96%. Corresponding values during periods of decreasing output were 90% and 84%, respectively. Precision was always better with NICOM than with thermodilution. During hemodynamic challenges, changes were 3.1 +/- 3.8min faster with NICOM (p < 0.01) and amplitude of changes did not differ significantly. Finally, sensitivity of the NICOM for detecting significant directional changes was 93% and specificity was 93%. Conclusion:Cardiac output measured by NICOM had most often acceptable accuracy, precision, and responsiveness in a wide range of circulatory situations.
引用
收藏
页码:1191 / 1194
页数:4
相关论文
共 50 条
  • [31] Noninvasive and Minimally Invasive Cardiac Output Monitoring A Nursing Perspective
    Berndsen, Michelle
    DIMENSIONS OF CRITICAL CARE NURSING, 2022, 41 (03) : 121 - 123
  • [32] EVALUATION OF NONINVASIVE CARDIAC OUTPUT MONITORING IN SHEEP WITH HEMODYNAMIC INSTABILITY
    Middleton, P. A.
    Reynolds, P. S.
    Spiess, B. D.
    Zhu, J.
    ANESTHESIA AND ANALGESIA, 2016, 122
  • [33] Noninvasive monitoring of cardiac output in critically ill patients with thoracocardiography
    Bloch, KE
    Baumann, PC
    Stocker, R
    Russi, EW
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (01) : 26 - 31
  • [34] Non-invasive cardiac output monitoring (NICOM) in adult congenital heart disease patients with Fontan palliation
    Quain, Angela
    Hoyer, Mark
    Ephrem, Georges
    Kay, W. Aaron
    INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE, 2021, 6
  • [35] Technical note: validation of cardiac output monitoring tools
    Squara, P.
    Chiche, J. -D.
    REANIMATION, 2011, 20 (02): : 129 - 137
  • [36] FLUID RESUSCITATION IN SEPTIC SHOCK USING NONINVASIVE CARDIAC OUTPUT MONITORING
    Organti, Nikhil
    Grady, Justin
    Donepudi, Bhargavi
    Tannehill, David
    O'Brien, Jacklyn
    Sadaka, Farid
    CRITICAL CARE MEDICINE, 2019, 47
  • [37] NONINVASIVE CARDIAC-OUTPUT MONITORING DURING EXERCISE STRESS TEST
    NANNA, M
    KAWANISHI, DT
    MCKAY, CR
    RAHIMTOOLA, SH
    NIMALASURIYA, A
    CHANDRARATNA, PAN
    CANADIAN JOURNAL OF CARDIOLOGY, 1988, 4 (04) : 165 - 168
  • [38] Advantages and limitations of noninvasive devices for cardiac output monitoring: a literature review
    Ruste, Martin
    Jacquet-Lagreze, Matthias
    Fellahi, Jean-Luc
    CURRENT OPINION IN CRITICAL CARE, 2023, 29 (03) : 259 - 267
  • [39] Reproducibility of Noninvasive Cardiac Output Monitoring During Exercise in Healthy Volunteers
    Barroso, Michael Coll
    Hoppe, Matthias
    Nickl, Werner
    Kiefer, Christian
    Mondritzki, Thomas
    Kramar, Frank
    Fritschka, Max
    Truebel, Hubert
    Duengen, Hans Dirk
    Krahn, Thomas
    Dinh, Wilfried
    CIRCULATION, 2017, 136
  • [40] Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine
    Saugel, B.
    Cecconi, M.
    Wagner, J. Y.
    Reuter, D. A.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 114 (04) : 562 - 575