Validation of Noninvasive Measurements of Cardiac Output in Mice Using Echocardiography

被引:48
|
作者
Tournoux, Francois [1 ,4 ]
Petersen, Bodil [2 ]
Thibault, Helene [1 ]
Zou, Lin [2 ]
Raher, Michael J. [2 ]
Kurtz, Baptiste [1 ]
Halpern, Elkan F. [3 ]
Chaput, Miguel [1 ]
Chao, Wei [2 ]
Picard, Michael H. [1 ]
Scherrer-Crosbie, Marielle [1 ]
机构
[1] Massachusetts Gen Hosp, Cardiac Ultrasound Lab, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Anesthesia Res Lab, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Inst Technol Assessment, Boston, MA 02114 USA
[4] Univ Paris 07, INSERM, Hop Lariboisiere, APHP,Dept Cardiol,U942, Paris, France
基金
美国国家卫生研究院;
关键词
Cardiac output; Doppler echocardiography; Flow probe; Mice; Sepsis; IN-VIVO; CONDUCTANCE CATHETER; VOLUME; PULMONARY; PERFUSION; MOUSE; RATS;
D O I
10.1016/j.echo.2010.12.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although multiple echocardiographic methods exist to calculate cardiac output (CO), they have not been validated in mice using a reference method. Methods: Echocardiographic and flow probe measurements of CO were obtained in mice before and after albumin infusion and inferior vena cava occlusions. Echocardiography was also performed before and after endotoxin injection. Cardiac output was calculated using left ventricular volumes obtained from an M-mode or a two-dimensional view, left ventricular stroke volume calculated using the pulmonary flow, or estimated by the measurement of pulmonary velocity time integral (VTI). Results: Close correlations were demonstrated between flow probe-measured CO and all echocardiographic measurements of CO. All echocardiographic-derived CO overestimated the flow probe-measured CO. Two-dimensional image-derived CO was associated with the smallest overestimation of CO. Interobserver variability was lowest for pulmonary VTI-derived CO. Conclusion: In mice, CO calculated from two-dimensional parasternal long-axis images is most accurate when compared with flow probe measurements; however, pulmonary VTI-derived CO is subject to less variability. (J Am Soc Echocardiogr 2011;24:465-70.)
引用
收藏
页码:465 / 470
页数:6
相关论文
共 50 条
  • [1] VALIDATION OF CARDIAC-OUTPUT MEASUREMENTS WITH NONINVASIVE DOPPLER-ECHOCARDIOGRAPHY BY THERMODILUTION AND FICK METHODS IN NEWBORN PIGLETS
    WELCH, E
    DUARA, S
    SUGUIHARA, C
    BANDSTRA, E
    BANCALARI, E
    BIOLOGY OF THE NEONATE, 1994, 66 (2-3): : 137 - 145
  • [2] Noninvasive techniques for measurements of cardiac output
    Cholley, BP
    Payen, D
    CURRENT OPINION IN CRITICAL CARE, 2005, 11 (05) : 424 - 429
  • [3] Cardiac Output Measurements Using Noninvasive Photoacoustic Measurements of Indicator Dilution Signals
    Li, Youzhi
    Baker, Clark
    Iyer, Darshan
    Huang, Qiaojian
    Borg, Ulf
    ANESTHESIA AND ANALGESIA, 2014, 119
  • [4] NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT BY DOPPLER ECHOCARDIOGRAPHY
    ALI, AS
    SERGAKOVA, LM
    MAREEV, VY
    KASEY, DV
    KARDIOLOGIYA, 1988, 28 (04) : 80 - 84
  • [5] Noninvasive cardiac output monitoring: a clinical validation
    P Squara
    P Estagnasie
    A Brusset
    D Denjean
    J Dib
    C Dubois
    Critical Care, 11 (Suppl 2):
  • [6] NONINVASIVE MEASUREMENTS OF CARDIAC-OUTPUT IN PREECLAMPSIA
    SIEKMANN, U
    CLINICAL AND EXPERIMENTAL HYPERTENSION PART B-HYPERTENSION IN PREGNANCY, 1984, 3 (2-3): : 293 - 293
  • [7] Development and validation of a noninvasive method to estimate cardiac output using cuff sphygmomanometry
    Chid, Shiu-Shin
    Tsai, Jeffrey J.
    Hsu, Yen-Ming
    Lapointe, Jeffrey C.
    Huynh-Covey, Thao
    Kwan, Oi Ling B.
    DeMaria, Anthony N.
    CLINICAL CARDIOLOGY, 2007, 30 (12) : 615 - 620
  • [8] Noninvasive cardiac output monitoring (NICOM): a clinical validation
    Pierre Squara
    Dominique Denjean
    Philippe Estagnasie
    Alain Brusset
    Jean Claude Dib
    Claude Dubois
    Intensive Care Medicine, 2007, 33 : 1191 - 1194
  • [9] VALIDATION OF NONINVASIVE MAXIMAL CARDIAC-OUTPUT MEASUREMENT
    SMYTH, RJ
    GLEDHILL, N
    FROESE, AB
    JAMNIK, VK
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1984, 16 (05): : 512 - 515
  • [10] Validation of a new spectrometer for noninvasive measurement of cardiac output
    Baum, MM
    Kumar, S
    Moss, JA
    Wagner, PD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (07): : 2290 - 2299