Validation of Noninvasive Measurements of Cardiac Output in Mice Using Echocardiography

被引:48
|
作者
Tournoux, Francois [1 ,4 ]
Petersen, Bodil [2 ]
Thibault, Helene [1 ]
Zou, Lin [2 ]
Raher, Michael J. [2 ]
Kurtz, Baptiste [1 ]
Halpern, Elkan F. [3 ]
Chaput, Miguel [1 ]
Chao, Wei [2 ]
Picard, Michael H. [1 ]
Scherrer-Crosbie, Marielle [1 ]
机构
[1] Massachusetts Gen Hosp, Cardiac Ultrasound Lab, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Anesthesia Res Lab, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Inst Technol Assessment, Boston, MA 02114 USA
[4] Univ Paris 07, INSERM, Hop Lariboisiere, APHP,Dept Cardiol,U942, Paris, France
基金
美国国家卫生研究院;
关键词
Cardiac output; Doppler echocardiography; Flow probe; Mice; Sepsis; IN-VIVO; CONDUCTANCE CATHETER; VOLUME; PULMONARY; PERFUSION; MOUSE; RATS;
D O I
10.1016/j.echo.2010.12.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although multiple echocardiographic methods exist to calculate cardiac output (CO), they have not been validated in mice using a reference method. Methods: Echocardiographic and flow probe measurements of CO were obtained in mice before and after albumin infusion and inferior vena cava occlusions. Echocardiography was also performed before and after endotoxin injection. Cardiac output was calculated using left ventricular volumes obtained from an M-mode or a two-dimensional view, left ventricular stroke volume calculated using the pulmonary flow, or estimated by the measurement of pulmonary velocity time integral (VTI). Results: Close correlations were demonstrated between flow probe-measured CO and all echocardiographic measurements of CO. All echocardiographic-derived CO overestimated the flow probe-measured CO. Two-dimensional image-derived CO was associated with the smallest overestimation of CO. Interobserver variability was lowest for pulmonary VTI-derived CO. Conclusion: In mice, CO calculated from two-dimensional parasternal long-axis images is most accurate when compared with flow probe measurements; however, pulmonary VTI-derived CO is subject to less variability. (J Am Soc Echocardiogr 2011;24:465-70.)
引用
收藏
页码:465 / 470
页数:6
相关论文
共 50 条
  • [31] Automatic optimization of resting and exercise atrioventricular interval using a peak endocardial acceleration sensor: Validation with Doppler echocardiography and direct cardiac output measurements
    Leung, SK
    Lau, CP
    Lam, CTF
    Ho, S
    Tse, HF
    Yu, CM
    Lee, K
    Tang, MO
    To, KM
    Renesto, F
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (11): : 1762 - 1766
  • [32] USCOM (Ultrasonic Cardiac Output Monitors) lacks agreement with thermodilution cardiac output and transoesophageal echocardiography valve measurements
    Van den Oever, H. L. A.
    Murphy, E. J.
    Christie-Taylor, G. A.
    ANAESTHESIA AND INTENSIVE CARE, 2007, 35 (06) : 903 - 910
  • [33] NONINVASIVE MATERNAL STROKE VOLUME AND CARDIAC-OUTPUT DETERMINATIONS BY PULSED DOPPLER ECHOCARDIOGRAPHY
    LEE, W
    ROKEY, R
    COTTON, DB
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1988, 158 (03) : 505 - 510
  • [34] Cardiac Resynchronization Therapy Optimization Using Noninvasive Cardiac Output Measurement
    Khan, Fakhar Z.
    Virdee, Munmohan S.
    Hutchinson, John
    Smith, Beverley
    Pugh, Peter J.
    Read, Philip A.
    Fynn, Simon P.
    Dutka, David P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (11): : 1527 - 1536
  • [35] Comparison of a noninvasive cardiac output monitor (NICOM) with simultaneous transthoracic echocardiography in pregnant women
    Florio, Karen
    Williams, Emily
    White, Darcy
    Daming, Tara Banaszek
    Hostetter, Sarah
    Schrufer-Poland, Tabitha L.
    Gray, Rebecca
    Schmidt, Laura
    Grodzinsky, Anna
    Lee, John
    Rader, Valerie
    Swearingen, Kathleen
    Nelson, Lynne
    Magalaski, Anthony
    Spertus, John
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (01) : S338 - S338
  • [36] NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT WITH PULSED DOPPLER ECHOCARDIOGRAPHY - COMPARISON WITH FICK PROCEDURE
    STRAUSS, AL
    KEDRA, AW
    PAYEN, DM
    LEVY, BI
    RIEGER, H
    MARTINEAUD, JP
    HERZ, 1986, 11 (05) : 269 - 276
  • [37] Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children
    Fremuth, Jiri
    Huml, Michal
    Pomahacova, Tereza
    Kobr, Jiri
    Kormunda, Stanislav
    Sykora, Josef
    PEDIATRIC EMERGENCY CARE, 2023, 39 (09) : 680 - 684
  • [38] COMPARISON OF CARDIAC OUTPUT MEASUREMENTS BETWEEN ELECTRICAL CARDIOMETRY (EC) AND ECHOCARDIOGRAPHY
    Cayabyab, R. G.
    Bhombal, S.
    Ebrahimi, M.
    Seri, I
    JOURNAL OF INVESTIGATIVE MEDICINE, 2011, 59 (01) : 125 - 125
  • [39] Reproducibility of cardiac output measurements by Doppler echocardiography in prepubertal children and adults
    Vinet, A
    Nottin, S
    Lecoq, AM
    Guenon, P
    Obert, P
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2001, 22 (06) : 437 - 441
  • [40] Validation of a noninvasive cardiac output monitor in maternal cardiac disease: comparison of NICOM and transthoracic echocardiogram
    Florio, Karen L.
    Williams, Emily M.
    White, Darcy
    Daming, Tara
    Hostetter, Sarah
    Schrufer-Poland, Tabitha
    Gray, Rebecca
    Schmidt, Laura
    Grodzinsky, Anna
    Lee, John
    Rader, Valerie
    Swearingen, Kathleen
    Nelson, Lynne
    Patel, Neil
    Magalski, Anthony
    Gosch, Kensey
    Jones, Philip
    Fu, Zhuxuan
    Spertus, John A.
    AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM, 2024, 6 (03)