Validation of Noninvasive Measurements of Cardiac Output in Mice Using Echocardiography

被引:48
|
作者
Tournoux, Francois [1 ,4 ]
Petersen, Bodil [2 ]
Thibault, Helene [1 ]
Zou, Lin [2 ]
Raher, Michael J. [2 ]
Kurtz, Baptiste [1 ]
Halpern, Elkan F. [3 ]
Chaput, Miguel [1 ]
Chao, Wei [2 ]
Picard, Michael H. [1 ]
Scherrer-Crosbie, Marielle [1 ]
机构
[1] Massachusetts Gen Hosp, Cardiac Ultrasound Lab, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Anesthesia Res Lab, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Inst Technol Assessment, Boston, MA 02114 USA
[4] Univ Paris 07, INSERM, Hop Lariboisiere, APHP,Dept Cardiol,U942, Paris, France
基金
美国国家卫生研究院;
关键词
Cardiac output; Doppler echocardiography; Flow probe; Mice; Sepsis; IN-VIVO; CONDUCTANCE CATHETER; VOLUME; PULMONARY; PERFUSION; MOUSE; RATS;
D O I
10.1016/j.echo.2010.12.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although multiple echocardiographic methods exist to calculate cardiac output (CO), they have not been validated in mice using a reference method. Methods: Echocardiographic and flow probe measurements of CO were obtained in mice before and after albumin infusion and inferior vena cava occlusions. Echocardiography was also performed before and after endotoxin injection. Cardiac output was calculated using left ventricular volumes obtained from an M-mode or a two-dimensional view, left ventricular stroke volume calculated using the pulmonary flow, or estimated by the measurement of pulmonary velocity time integral (VTI). Results: Close correlations were demonstrated between flow probe-measured CO and all echocardiographic measurements of CO. All echocardiographic-derived CO overestimated the flow probe-measured CO. Two-dimensional image-derived CO was associated with the smallest overestimation of CO. Interobserver variability was lowest for pulmonary VTI-derived CO. Conclusion: In mice, CO calculated from two-dimensional parasternal long-axis images is most accurate when compared with flow probe measurements; however, pulmonary VTI-derived CO is subject to less variability. (J Am Soc Echocardiogr 2011;24:465-70.)
引用
收藏
页码:465 / 470
页数:6
相关论文
共 50 条
  • [41] Noninvasive cardiac output monitoring
    Popovich, MJ
    Hoffman, WD
    CRITICAL CARE MEDICINE, 1997, 25 (11) : 1783 - 1784
  • [42] Noninvasive cardiac output monitoring
    Dueck, R
    CHEST, 2001, 120 (02) : 339 - 341
  • [43] Validation of noninvasive pulse contour cardiac output using finger arterial pressure in cardiac surgery patients requiring fluid therapy
    Hofhuizen, Charlotte
    Lansdorp, Benno
    van der Hoeven, Johannes G.
    Scheffer, Gert-Jan
    Lemson, Joris
    JOURNAL OF CRITICAL CARE, 2014, 29 (01) : 161 - 165
  • [45] VALIDATION OF ULTRASOUND DILUTION CARDIAC OUTPUT MEASUREMENTS IN PEDIATRIC PATIENTS
    Crittendon, Ivory
    Dreyer, William
    Kim, Jeffrey
    CRITICAL CARE MEDICINE, 2009, 37 (12) : A90 - A90
  • [46] VALIDATION OF RADIONUCLIDE CARDIAC-OUTPUT MEASUREMENTS DURING EXERCISE
    MELIN, JA
    WIJNS, W
    ROBERT, A
    NANNAN, M
    DECOSTER, P
    BECKERS, C
    DETRY, JM
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (12) : 1386 - 1393
  • [47] CARDIAC OUTPUT MEASUREMENT BY ECHOCARDIOGRAPHY
    KINGSLEY, B
    FLINT, G
    BELL, D
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1969, SU16 (01): : 31 - &
  • [48] Noninvasive Cardiac Output Monitoring by Electrical Cardiometry with Transthoracic Echocardiography in Postoperative Paediatric Cardiac Surgical Patients: Comment
    Daungsupawong, Hinpetch
    Wiwanitkit, Viroj
    ANNALS OF CARDIAC ANAESTHESIA, 2024, 27 (02) : 178 - 179
  • [49] Noninvasive and simultaneous measurements of circulating blood volume and cardiac output in infants and children
    Tanigami, H
    He, YL
    Ueyama, H
    Taniguchi, A
    Mashimo, T
    Yoshiya, I
    ANESTHESIA AND ANALGESIA, 1997, 84 : S274 - S274
  • [50] The accuracy of noninvasive cardiac output and pressure measurements with finger cuff: a concise review
    Ameloot, Koen
    Palmers, Pieter-Jan
    Malbrain, Manu L. N. G.
    CURRENT OPINION IN CRITICAL CARE, 2015, 21 (03) : 232 - 239