摘要
Purpose of review The present review aims to summarize literature on the accuracy of the finger cuff method to measure cardiac output (CO) and blood pressure, its ability to track hemodynamic changes, and to predict fluid responsiveness. Recent findings Finger cuff is an easy-to-use hemodynamic monitoring technique. Different devices are currently available, which provide continuous arterial blood pressure (Finapress), whereas only ClearSight (previously known as Nexfin; BMEYE) provides an estimate of CO. In most studies, the criteria for clinical interchangeability (for CO) were not met, when compared with the currently used invasive monitoring systems such as uncalibrated CO via a radial artery line, and calibrated CO either via a pulmonary artery catheter or a femoral artery catheter connected to the PiCCO (Pulsion Medical Systems) or VolumeView (Edwards Lifesciences) devices. In particular, ClearSight obtained CO seems to be less accurate in patients with a low CO. However, in most patients, ClearSight is able to track hemodynamic changes induced by a fluid challenge or passive leg raising test. We will discuss in this review the relevant literature with regard to validation of the finger cuff technique for both arterial blood pressure and CO. Summary The finger cuff method provides a reasonable estimate of CO and blood pressure, which does not meet the criteria for clinical interchangeability with the currently used invasive devices.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 50 条
  • [1] Noninvasive Cardiac Output and Central Systolic Pressure From Cuff-Pressure and Pulse Wave Velocity
    Bikia, Vasiliki
    Pagoulatou, Stamatia
    Trachet, Bram
    Soulis, Dimitrios
    Protogerou, Athanase D.
    Papaioannou, Theodore G.
    Stergiopulos, Nikos
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (07) : 1968 - 1981
  • [2] Noninvasive techniques for measurements of cardiac output
    Cholley, BP
    Payen, D
    CURRENT OPINION IN CRITICAL CARE, 2005, 11 (05) : 424 - 429
  • [3] NONINVASIVE MEASUREMENTS OF CARDIAC PRESSURE
    SCULLY, MO
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (08) : 576 - 576
  • [4] The impact of blood pressure cuff location on the accuracy of noninvasive blood pressure measurements in obese patients: an observational study
    Anast, Nicholas
    Olejniczak, Megan
    Ingrande, Jerry
    Brock-Utne, John
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2016, 63 (03): : 298 - 306
  • [5] Accuracy improvement of noninvasive finger blood pressure measurement
    Lackovic, I
    Santic, A
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 281 - 284
  • [6] Noninvasive assessment of cardiac output in critically ill patients by analysis of the finger blood pressure waveform
    Hirschl, MM
    Binder, M
    Gwechenberger, M
    Herkner, H
    Bur, A
    Kittler, H
    Laggner, AN
    CRITICAL CARE MEDICINE, 1997, 25 (11) : 1909 - 1914
  • [7] NONINVASIVE MEASUREMENTS OF CARDIAC-OUTPUT IN PREECLAMPSIA
    SIEKMANN, U
    CLINICAL AND EXPERIMENTAL HYPERTENSION PART B-HYPERTENSION IN PREGNANCY, 1984, 3 (2-3): : 293 - 293
  • [8] Continuous noninvasive pulse wave analysis using finger cuff technologies for arterial blood pressure and cardiac output monitoring in perioperative and intensive care medicine: a systematic review and meta-analysis
    Saugel, Bernd
    Hoppe, Phillip
    Nicklas, Julia Y.
    Kouz, Karim
    Koerner, Annmarie
    Hempell, Julia C.
    Vos, Jaap J.
    Schoen, Gerhard
    Scheeren, Thomas W. L.
    BRITISH JOURNAL OF ANAESTHESIA, 2020, 125 (01) : 25 - 37
  • [9] A new continuous noninvasive finger cuff device (Vitalstream) for cardiac output that communicates wirelessly via bluetooth or Wi-Fi
    Gratz, Irwin
    Baruch, Martin
    Awad, Ahmed
    McEniry, Brian
    Allen, Isabel
    Seaman, Julia
    BMC ANESTHESIOLOGY, 2023, 23 (01)
  • [10] A new continuous noninvasive finger cuff device (Vitalstream) for cardiac output that communicates wirelessly via bluetooth or Wi-Fi
    Irwin Gratz
    Martin Baruch
    Ahmed Awad
    Brian McEniry
    Isabel Allen
    Julia Seaman
    BMC Anesthesiology, 23