Noninvasive assessment of cardiac output in critically ill patients by analysis of the finger blood pressure waveform

被引:33
|
作者
Hirschl, MM
Binder, M
Gwechenberger, M
Herkner, H
Bur, A
Kittler, H
Laggner, AN
机构
[1] UNIV VIENNA,NEW GEN HOSP,DEPT DERMATOL,A-1090 VIENNA,AUSTRIA
[2] UNIV VIENNA,NEW GEN HOSP,DEPT CARDIOL,A-1090 VIENNA,AUSTRIA
关键词
thermodilution method; MODELFLOW computer program; cardiac output; noninvasive; stroke volume; pulmonary artery catheter; critically ill patients; emergency medicine; intensive care medicine; finger blood pressure measurement;
D O I
10.1097/00003246-199711000-00033
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To assess whether the measurement of cardiac output by computer-assisted analysis of the finger blood pressure waveform can substitute for the thermodilution method in critically ill patients. Design: Prospective data collection. Setting: Emergency department in a 2000-bed inner city hospital. Patients: Forty-six critically ill patients requiring invasive monitoring for clinical management were prospectively studied. Interventions: Under local anesthesia a 7-Fr pulmonary artery catheter was inserted via the central subclavian or jugular vein. Cardiac output was determined by the use of a cardiac output computer and injections of 10 mt ice-cold glucose 5%. Noninvasive cardiac output was calculated from the finger blood pressure waveform by the use of the test software program. Measurements and Main Results: Three hundred twenty-three pairs of invasive and noninvasive hemodynamic measurements were collected in intervals of 30 mins from 46 patients (mean age 61.9 +/- 12.4 yrs; 35 male, 11 female). The average cardiac index during the study period was 2.83 L/min/m(2) (range 0.97 to 5.56). The overall discrepancy between both measurements was 0.14 L/min/m(2) (95% confidence interval: 0.10-0.18, p <.001). Seventy-five (23.2%) measurements had an absolute discrepancy >+/-0.50 L/min/m(2). Noninvasive and invasive comparisons of mean differential cardiac output were out of phase for 9.7% of all readings. Conclusion: Computer-assisted analysis of finger blood pressure waveform to assess cardiac output is not a substitute for the thermodilution method due to a high percentage (23.2%) of inaccurate readings; however, it may be a useful tool for the detection of relative hemodynamic trends in critically ill patients.
引用
收藏
页码:1909 / 1914
页数:6
相关论文
共 50 条
  • [1] Noninvasive Cardiac Output Assessment In Critically Ill Pediatric Patients
    Wongsirimetheekul, T.
    Khositseth, A.
    Lertbunrian, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [2] Accuracy and reliability of noninvasive continuous finger blood pressure measurement in critically ill patients
    Hirschl, MM
    Binder, M
    Herkner, H
    Bur, A
    Brunner, M
    Seidler, D
    Stuhlinger, HG
    Laggner, AN
    CRITICAL CARE MEDICINE, 1996, 24 (10) : 1684 - 1689
  • [3] Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients
    Stover J.F.
    Stocker R.
    Lenherr R.
    Neff T.A.
    Cottini S.R.
    Zoller B.
    Béchir M.
    BMC Anesthesiology, 9 (1) : 6
  • [4] Noninvasive monitoring of cardiac output in critically ill patients with thoracocardiography
    Bloch, KE
    Baumann, PC
    Stocker, R
    Russi, EW
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (01) : 26 - 31
  • [5] Accuracy assessment of noninvasive cardiac output monitoring in the hemodynamic monitoring in critically ill patients
    Zhu, Guijun
    Zhang, Kun
    Fu, Yuxin
    Hu, Zhenjie
    ANNALS OF PALLIATIVE MEDICINE, 2020, 9 (05) : 3506 - 3512
  • [6] Noninvasive measurement of cardiac output in critically ill children
    Mohan, UR
    Britto, J
    Habibi, P
    de Munter, C
    Nadel, S
    PEDIATRIC CARDIOLOGY, 2002, 23 (01) : 58 - 61
  • [7] Noninvasive Measurement of Cardiac Output in Critically Ill Children
    U.R. Mohan
    J. Britto
    P. Habibi
    C. Munter
    S. Nadel
    Pediatric Cardiology, 2002, 23 : 58 - 61
  • [8] Blood pressure monitoring in the critically ill patient: A place for noninvasive assessment?
    Sakka, Samir G.
    CRITICAL CARE MEDICINE, 2012, 40 (04) : 1366 - 1367
  • [9] Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis
    Lu, Zhenwei
    Mukkamala, Ramakrishna
    JOURNAL OF APPLIED PHYSIOLOGY, 2006, 101 (02) : 598 - 608
  • [10] Noninvasive monitors of blood pressure in the critically ill
    Lakhal, Karim
    Martin, Maelle
    Ehrmann, Stephan
    Boulain, Thierry
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2015, 32 (05) : 367 - 368