Cardiac Resynchronization Therapy Optimization Using Noninvasive Cardiac Output Measurement

被引:22
|
作者
Khan, Fakhar Z. [1 ]
Virdee, Munmohan S. [2 ]
Hutchinson, John [2 ]
Smith, Beverley [1 ]
Pugh, Peter J. [1 ]
Read, Philip A. [1 ]
Fynn, Simon P. [2 ]
Dutka, David P. [1 ]
机构
[1] Addenbrookes Hosp, Dept Cardiovasc Med, Cambridge CB2 2QQ, England
[2] Papworth Hosp, Dept Cardiol, Cambridge CB3 8RE, England
来源
关键词
cardiac output; CRT; optimization; noninvasive; CHRONIC HEART-FAILURE; HEMODYNAMIC IMPROVEMENT; ATRIOVENTRICULAR DELAY; DILATED CARDIOMYOPATHY; OXYGEN-CONSUMPTION; SYSTOLIC FUNCTION; CONDUCTION DELAY; POWER OUTPUT; SCAR TISSUE; TRIAL;
D O I
10.1111/j.1540-8159.2011.03172.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Noninvasive cardiac output (CO) measurement (NICOM) is a novel method to assess ventricular function and offers a potential alternative for optimization of cardiac resynchronization therapy (CRT) devices. We compared the effect of NICOM-based optimization to no optimization (empiric settings) on CRT outcomes. Methods: Two hundred and three patients undergoing CRT were assessed in two consecutive nonrandomized groups; an empiric group (n = 54) was programmed to " out of the box" settings with a fixed AV delay of 120 ms and a VV delay of 0 ms; and the optimization group (n = 149) underwent adjustments of both the AV and VV delays according to the greatest improvement in resting CO. The primary endpoints were improvements in left ventricular (LV) volumes and function from baseline at 6 months. Secondary endpoints were change in New York Heart Association (NYHA) class, quality of life score, and 6-minute walk test (6 MWT) performance. Results: After 6 months of CRT, the optimization group had a better clinical response with lower NYHA class (2.1 +/- 0.8 vs 2.4 +/- 0.8, P = 0.048) and quality of life scores (35 +/- 18 vs 42 +/- 20, P = 0.045) but no differences in 6-MWT performance (269 +/- 110 vs 277 +/- 114 m, P = 0.81). Echocardiographic response was also better in the optimization group with lower LV end systolic volume (108 +/- 51 vs 126 +/- 60 mL, P = 0.048) and higher ejection fraction (30 +/- 7 vs 27 +/- 8, P = 0.01) compared to empiric settings. Conclusion: Device optimization using noninvasive measures of CO is associated with better clinical and echocardiographic response compared to empiric settings. (PACE 2011; 34: 1527-1536)
引用
收藏
页码:1527 / 1536
页数:10
相关论文
共 50 条
  • [1] Noninvasive cardiac output measurement based optimization in nonresponders of cardiac resynchronization therapy
    Yenercag, Mustafa
    Yuksel, Serkan
    Coksevim, Metin
    Akcay, Murat
    Arslan, Ugur
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (04): : 394 - 401
  • [2] Noninvasive, automatic optimization strategy in cardiac resynchronization therapy
    Reumann, Matthias
    Osswald, Brigitte
    Doessel, Olaf
    ANADOLU KARDIYOLOJI DERGISI-THE ANATOLIAN JOURNAL OF CARDIOLOGY, 2007, 7 : 209 - 212
  • [3] Measurement Precision in the Optimization of Cardiac Resynchronization Therapy
    Turcott, Robert G.
    Witteles, Ronald M.
    Wang, Paul J.
    Vagelos, Randall H.
    Fowler, Michael B.
    Ashley, Euan A.
    CIRCULATION-HEART FAILURE, 2010, 3 (03) : 395 - 404
  • [4] Cardiac resynchronization therapy optimization by ultrasonic cardiac output monitoring (USCOM) device
    Siu, Chung-Wah
    Tse, Hung-Fat
    Lee, Kathy
    Chan, Hon-Wah
    Chen, Wai-Hong
    Yung, Cindy
    Lee, Stephen
    Lau, Chu-Pak
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (01): : 50 - 55
  • [5] Optimization of cardiac resynchronization therapy
    Bhan, Amit
    Kapetanakis, Stamatis
    Monaghan, Mark J.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (09): : 1031 - 1039
  • [6] The correlation between six minute walking test distance and noninvasive cardiac output measurements before and after cardiac resynchronization therapy optimization
    Yuksel, S. Serkan
    Yenercag, M.
    Coksevim, M.
    Seker, O. O.
    Yilmaz, O.
    Sahin, M.
    EUROPEAN JOURNAL OF HEART FAILURE, 2016, 18 : 231 - 232
  • [7] NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT
    BULLER, NP
    LANCET, 1987, 1 (8526): : 215 - 215
  • [8] NONINVASIVE CARDIAC-OUTPUT MEASUREMENT
    WONG, DH
    WESTERN JOURNAL OF MEDICINE, 1990, 153 (03): : 310 - 310
  • [9] Iterative Cardiac Output Measurement for Optimizing Cardiac Resynchronization Therapy: A Randomized, Blinded, Crossover Study
    Reinsch, Nico
    Konorza, Thomas
    Woydowski, Dagmar
    Bruck, Heike
    Volsek, Michaela
    Mueller-Tasch, Thomas
    Neumann, Till
    Erbel, Raimund
    Wieneke, Heinrich
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (10): : 1188 - 1194
  • [10] Impedance Cardiography as a Noninvasive Technique for Atrioventricular Interval Optimization in Cardiac Resynchronization Therapy
    Martin U. Braun
    Andreas Schnabel
    Thomas Rauwolf
    Matthias Schulze
    Ruth H. Strasser
    Journal of Interventional Cardiac Electrophysiology, 2005, 13 : 223 - 229