Skin models and their impact on mean glandular dose in mammography

被引:14
|
作者
Massera, Rodrigo Trevisan [1 ]
Tomal, Alessandra [1 ]
机构
[1] Univ Estadual Campinas, Inst Fis Gleb Wataghin, BR-13083859 Campinas, Brazil
基金
巴西圣保罗研究基金会;
关键词
Monte Carlo; Mammography; Dosimetry; Skin model; X-RAY-SPECTRA; MONTE-CARLO-SIMULATION; BREAST DOSIMETRY; DIGITAL MAMMOGRAPHY; CONVERSION FACTORS; DGN COEFFICIENTS; PHANTOM; VALUES; CT;
D O I
10.1016/j.ejmp.2018.04.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantify the influence of different skin models on mammographic breast dosimetry, based on dosimetric protocols and recent breast skin thickness findings. Methods: By using an adapted PENELOPE (v. 2014)+ PenEasy (v. 2015) Monte Carlo (MC) code, simulations were performed in order to obtain the mean glandular dose (MGD), the normalized MGD by incident air Kerma (DgN), and the glandular depth dose (GDD(z)). The geometry was based on a cranio-caudal mammographic examination. Monoenergetic and polyenergetic beams were implemented, for a breast thickness from 2 cm to 9 cm, with different compositions. Seven skin models were used: a 5mm adipose layer; a skin layer ranging from 5mm to 1.45 mm, a 1.45mm skin thickness with a subcutaneous adipose layer of 2mm and 3.55 mm. Results: The differences, for monoenergetic beams, are higher (up to 200%) for lower energies (8 keV), thicker and low glandular content breasts, decreasing to less than 5% at 40 keV. Without a skin layer, the differences reach a maximum of 1240%. The relative difference in DgN values for 1.45mm skin and 5mm adipose layers and polyenergetic beams varies from -14% to 12%. Conclusions: The implemented MC code is suitable for mammography dosimetry calculations. The skin models have major impacts on MGD values, and the results complement previous literature findings. The current protocols should be updated to include a more realistic skin model, which provides a reliable breast dose estimation.
引用
收藏
页码:38 / 47
页数:10
相关论文
共 50 条
  • [21] A Monte Carlo model for mean glandular dose evaluation in spot compression mammography
    Sarno, Antonio
    Dance, David R.
    van Engen, Ruben E.
    Young, Kenneth C.
    Russo, Paolo
    Di Lillo, Francesca
    Mettivier, Giovanni
    Bliznakova, Kristina
    Fei, Baowei
    Sechopoulos, Ioannis
    [J]. MEDICAL PHYSICS, 2017, 44 (07) : 3848 - 3860
  • [22] Dosimetric evaluation of the mean glandular dose for mammography in Korean women: A preliminary report
    Oh, KK
    Hur, J
    Kim, EK
    Choo, SS
    [J]. YONSEI MEDICAL JOURNAL, 2003, 44 (05) : 863 - 868
  • [23] MODEL FOR COMPUTING TUNGSTEN TUBE SPECTRA AND MEAN GLANDULAR DOSE FOR DIGITAL MAMMOGRAPHY
    SPIVEY, BA
    ANDRE, MP
    STOLLER, M
    TRAN, J
    [J]. RADIOLOGY, 1995, 197 : 291 - 291
  • [24] A Study of Mean Glandular Dose during Diagnostic Mammography in Hospitals in Hanoi, Vietnam
    Nguyen Thai Ha
    Nguyen Duc Thuan
    Nguyen Thu Van
    [J]. THIRD INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM, 2010, 27 : 263 - 265
  • [25] Investigation of mean glandular dose versus compressed breast thickness relationship for mammography
    Bor, Dogan
    Tukel, Selma
    Olgar, Turan
    Toklu, Tuerkay
    Aydin, Elif
    Akyol, Oya
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 160 - 164
  • [26] Retrospective Determination of Personalized Mean Glandular Dose Coefficients for Conventional Mammography Using Heterogeneously-Layered Breast Models
    Porras-Chaverri, M.
    Vetter, J.
    Highnam, R.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [27] Evaluation of mean glandular dose from mammography screening: A single-center study
    Alahmad, Haitham
    AlEnazi, Khaled
    Alshahrani, Abdulrhman
    Albariqi, Saleh
    Alnafea, Mohammed
    [J]. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (04)
  • [28] A study of mean glandular dose during diagnostic mammography in Malaysia and some of the factors affecting it
    Jamal, N
    Ng, KH
    McLean, D
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (904): : 238 - 245
  • [29] Results of a 2011 national questionnaire for investigation of mean glandular dose from mammography in Japan
    Asada, Y.
    Suzuki, S.
    Minami, K.
    Shirakawa, S.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (01) : 125 - 132
  • [30] Normalized mean glandular dose computation from mammography using GATE: a validation study
    Myronakis, Marios E.
    Zvelebil, Marketa
    Darambara, Dimitra G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2247 - 2265